Static and dynamic trial experiments indicate that the system, not only can well simulate the prime governor and self _ equilibrium characteristics of a prime mover with its simple hardware line, small size and versatility, but also can highly improve the whole system ' s control precision, reliability and stability when compared with the system design of the analogy circuits
靜態、動態測試實驗表明:該控制系統,不僅硬體線路大為簡化、體積小、通用性強,能夠很好地實現對原型調速器及原動機自平衡特性的模擬,而且與模擬電路的設計方案相比,整個系統的控制精度、可靠性和穩定性等大幅度提高,具有明顯的優勢。For a class of series - wound active power line conditioner the design approach law of a new fuzzy integral sliding mode variable structure control is presented. this method adjusts power electronic switch in order to achieve anticipated balance volt, finally makes active power line conditioner not only possess good robustness of variable - structure control and decrease vibration to the most but also increase the steady state precision. series - wound aplc adopted this control method possesses good dynamic and steady state performance
針對串聯型有源電網調節器運用變結構控制策略,調節電力電子開關模式,以獲得預期的平衡電壓,對串聯型有源電網調節器提出了模糊積分變結構控制方法,使串聯型有源電網調節器既保持了常規滑模控制強魯棒性的優點,又減弱了滑模控制的抖振,提高了系統的穩態精度,使系統具有良好的動態和靜態性能,模擬試驗表明該控制策略是一種十分有效的控制方法。The blade is made of whole cast stainless steel and passed dynamic and motionless balance tests
漿葉為整體不銹鋼鑄造,且通過動、靜平衡試驗精製而成。Bonded abrasive products - static balancing of grinding wheels - testing
粘合磨料產品.砂輪的靜態平衡試驗Welding in construction site and static balance tests of the runner of no. 1 turbine of longtan hydropower station
龍灘水電站1號機轉輪組焊及靜平衡試驗Comparison between quasi - static indentation and low - velocity impact tests has been conducted in this paper at last. in accordance with energy balance principle, the dent depth vs. peak contact force under impact curve, which is derived from the dent depth vs. impact energy curve, is similar with the dent depth vs. indentation force curve with an evident transition
最後,本文還對低速沖擊試驗與靜壓痕試驗做了比較分析,並基於能量平衡公式,從沖擊能量凹坑深度關系導出了沖擊最大接觸力凹坑深度關系曲線,它與靜壓痕試驗得出的壓痕力凹坑深度曲線的變化趨勢相類似,即出現較明顯的拐點。Aimed at the practical performance of soft clay, the static equilibrium equations taking consideration of effect of mass change, with the introduction of soil configuration, soil convection formula and mass conservation theory in soil, are derived, which reveal the phenomenon of coupling of total stress and seepage in equilibrium equations. then, some advisable experimental means are explored to determine the effect of mass change during consolidation. objective stress and strain should be used in large strain analysis
針對軟粘土大變形固結的實際性狀,文中引入了土體構形的概念,土體傳運公式和土體質量守恆定律,並由此導出了考慮變質量效應的大變形固結靜力平衡方程,揭示了平衡方程中存在的總應力與滲流相互耦合的效應,並考慮了固液兩相的可壓縮性,進一步探索了測試變質量效應的試驗方法。The blades have been passed the test of the dynamic and static balance testing machine
漿葉均通過靜、動平衡試驗機特殊試驗。The comparative tests of compaction - under reamed bored piles and column bored piles at same sites separately in jiaxing and huzhou city of province zhejiang were studied through self balanced method
本文在採用自平衡法靜載荷試驗的基礎上,分別對浙江嘉興和湖州兩個工程中的同一場地擠擴支盤灌注樁與普通直孔灌注樁進行對比試驗研究。The blades have passed the test of dynamic balance and static equilibrium
漿葉均通過靜動平衡試驗。Its blades casted by stainless steel have been passed the test of dynatic and static balance procisely
漿葉為整體不銹鋼鑄造,且通過動、靜平衡試驗精製而成。The test results demonstrate that this prototype has excellent comprehensive performances such as small bulk, lower weight, high efficiency, high steady precision, fast dynamic response, wide range input voltage, good output waveforms, strong over - load and short - circuit ability, and strong function with different nature load and three - phase unbalanced load
試驗結果表明,該變流器具有體積重量小、變換效率高、靜態精度高、動態響應快、輸入電壓變化范圍寬、輸出波形質量高、過載與短路能力強、帶不同性質負載和帶三相不平衡負載的能力強等優良的綜合性能。Test method of static unbalance for aircraft tyres
航空輪胎靜平衡差度試驗方法Static unbalance test method for aircraft tyre
航空輪胎靜平衡差度試驗方法Static balancing machine
靜平衡試驗機Load test is difficult to be carried with the development of higher bearing capacity and long length. as a new measuring technology, self - balanced method has its advantage on technology and economy. at present it is first load test method in north american and it has been applied in some province in china
作為一種新興的單樁承載力測試技術? ?自平衡試樁法,其測試技術的優越性及其在經濟上的巨大潛力,目前在北美已被公認為是進行基樁靜荷載試驗的首選方法,在我國的北京、江蘇、甘肅的等地區也已經開始小范圍地試用。It is based on the mean square error ( mse ) principle and we prove the validity of the method by computer simulations. to make a thorough understanding of mimo adaptive equalization system, in this thesis the author : 1 ) ananlyze the characteristics of mimo wideband channels and the modeling and simulation of 3gpp scm ; 2 ) research the capability of mimo linear adaptive equalization and mimo non - linear adaptive equalization by computer simulations ; 3 ) present a new method for selecting the order of adfe model 4 ) implement the adfe on adsp - 21160 for static image transmission, and already achieve satisfactory experimental result, which make a foundation for mimo adaptive equalization to be appllied in the real communication systems
為對mimo自適應均衡系統性能和設計做更深入的理解和研究,本文主要: 1 )研究了寬帶選擇衰落通道特性及3gppscm通道建模模擬; 2 ) mimo線性自適應均衡器和mimo非線性自適應均衡器系統的性能分析和模擬實現; 3 ) mimo系統下的判決反饋均衡器的階數選擇模擬試驗分析; 4 )把mimo自適應判決反饋均衡運用到了硬體模擬平臺上,採用了基於adsp - 21160的硬體dsp開發板,對靜止圖片的傳輸進行了試驗、分析和比較,得到了較滿意的實驗結果,使mimo自適應均衡在實際通信系統上的應用及實現奠定了現實基礎。The contrast test between self - balance test and top load test has been done applying the research of the article, it shows that the transferred curves are well consistent with top load curves, so it can satisfy the engineering requirement and its accuracy can amount to about ninety percent
結果表明:自平武漢理工大學碩士學位論文衡試樁法與傳統靜載試驗具有較好的一致性;採用本文的提出的數據轉換分析方法,轉換曲線與傳統靜載曲線吻合性較好,極限承載力的判定誤差在10 %左右,能夠滿足工程精度的要求。Based on above three methods of transferring self - balanced test data into top load data have been provided and relative computer program has been edited
結合本文的研究成果,在實際工程中進行了自平衡試樁法與靜載試驗的對比試驗。Bonded abrasive products - permissible unbalances of grinding wheels as delivered - static testing
粘合磨料產品.砂輪交貨時的允許不平衡性.靜態試驗分享友人