alarm failure 中文意思是什麼

alarm failure 解釋
漏報警
  • alarm : n. 1. 驚慌,恐慌。2. 警報,急報。3. 警報器,警鈴。vt. 1. 向…告急,向…報警,警戒。2. 嚇,驚動;使放心不下。
  • failure : n 1 失敗 (opp success); 不及格。2 不足,缺乏;衰退;【醫學】衰竭。3 不履行,玩忽。4 破產,倒閉...
  1. The combination seal failure / overtemp alarm relay is a specialized control for monitoring seal failure and thermal overload of one ( 1 ) submersible pump motor

    密封故障和過熱故障兩用報警繼電器是一個專用控制裝置,用於監測一( 1 )臺潛水泵電機的密封故障和熱過載。
  2. Equipped with electronic controller fini tronic and preset for remote control for two or more compressors. it offers working pressure and oil mist separator tank inner pressure indication, separator filter clogging lashing alarm before overpressure e - stop, electric motor temperature control, maximum screw assembly temperature control, air temperature on pressure end indication, electric motor direction of rotation check, time to scheduled maintenance term, total operating hours and operating hours under load, alarm log of last five failure events

    並預設為丙臺以上空壓機聯機遠程控制,有工作壓力和油氣分離器罐內壓指示,分離器過濾器阻塞報警,電機溫控,螺桿總成溫控,壓力端空氣溫度指示,電機轉向檢查,維護周期油,油過濾器,空氣過濾器,分離器過濾器,總運行時間和負載運行時間,記錄上五個報警故障等。
  3. It offers working pressure and oil mist separator tank inner pressure indication, separator filter clogging flashing alarm before overpressure e - stop, electric motor temperature control, maximum screw assembly temperature control, air temperature on pressure and indication, electric motor direction of rotation check, time to scheduled maintenance term, total operating hours and operating hours under load, alarm log of last five failure events

    並預設為丙臺以上空壓機聯機遠程控制可檢測包括操作壓力油氣分離器罐內壓,電機溫度和轉向,螺桿總成溫度過濾器堵塞報警等參數,並可顯示總運行時間和負載運行時間。
  4. Self - diagnose executed when tip temperature is below alarm level and heater or circuit board failure, warning signal and power off automatically

    當焊咀溫度低於警誡線,發熱芯或線路板故障時,自診執行並發出信號提示及后自動關機
  5. Hardware circuit includes the unit loop circuits such as main loop circuit, drive circuit, control circuit, protective circuit, the circuit of power source and displaying circuit etc. the function that the induction cooker can realizes are mainly as follows : heat function, warm function, time function, no pan detecting and alarm function, which includes overheat alarm, over voltage or under voltage alarm, fan failure alarm etc. the displaying interface has digital number display indicator and vacuum fluorescent display

    硬體電路主要包括主迴路、激勵電路、控制電路、保護電路、電源電路和顯示電路等單元迴路,主要實現的功能如下:加熱功能、定溫功能、定時功能、無鍋檢測功能、報警功能,具體包括過熱報警、過壓或者欠壓報警、風扇失效報警等。顯示界面有數碼管顯示和真空熒光屏顯示。
  6. Ecr fire alarm should be separate from the fire detection unit failure or must have two different messages

    集控室消防警報應與煙火探測裝置失效(報警信號)分開,否則必須設有兩個不同的信息。
  7. A lot of software for the measurement and control system of the codog power plant experiment rig are able to collect the status parameters of the diesel, gas turbine, gear box and electrical vortex dynamometer, to manage the data, to display, to store the data, to judge of working status and to alarm the failure

    編制了codog物理模擬實驗臺測控系統軟體,主要任務是完成柴油機、燃氣輪機、並車齒輪箱和電渦流測功器各狀態參數的採集、數據處理及顯示、數據保存、狀態判斷和故障報警等內容。
  8. Single parameter provides little message and sometimes it is difficult to make an exact evaluate. in this paper, by testing the sensitivity of the system model, three parameters are selected as sensitive parameters, and based on simulation result of the system model, three dimension failure surface is used for alarm criterion and arithmetic of the alarm is carried out

    單一參數提供的信息較少,有時難以作出準確的評價,本文通過對系統模型的靈敏度測試,選取三個參數作為靈敏參數,根據系統模型的模擬結果,以三維失效面作為報警判據,並實現了報警演算法。
  9. But, the alarm signals from scada have disadvantages as follows : ( 1 ) the open - air feeder terminal units ( ftu ) are interfered by strong electromagnetic and thunder. besides, the failure of relays and the fault of ftu can also lead to that fault information is interfered and aberrant. ( 2 ) in the process of transmission and commutation, the error in the communication equipment may result in the signals err or lose

    然而,現有的scada系統在配電網發生故障時提供給調度員的警報信息有如下局限性: ( 1 )面向現場的戶外饋線終端ftu運行環境惡劣,承受強的電磁、雷電干擾,並且由於繼電器節點故障、 ftu元器件損壞等因素的存在,使得配電網信息受干擾、畸變的可能性較高; ( 2 )在信號傳輸及變換過程中,通訊裝置的故障等原因,也可能導致信號出錯甚至丟失; ( 3 )保護裝置和斷路器本身也有可能誤動或拒動。
  10. As adaptability and failure diagnosis function of the algorithm the problems causing wrong alarm by former flame detecting are resolved and the reliability of the system is higher

    演算法具有自適性和故障診斷功能,解決了常規火焰檢測裝置的誤報問題,提高了系統的可靠性。
  11. The sliding bearing is chosen as the research object, and its system dynamics model of the heat plane and agglutination state are found. the three - dimension failure surface of temperature - verity - load is put forward as alarm criterion. with this method, the developing trend of fault can be forecasted truly, then the veracity of fault alarm can be improved

    本文首次將系統動力學方法用於機械設備的事故報警,並以滑動軸承為例建立了熱平面系統動力學模型和膠合狀態系統動力學模型,提出以溫度?速度?載荷三維失效面作為報警判據,可較為準確地預測故障的發展趨勢,提高事故報警的準確性。
  12. If trip occurs due to a failure during operation, the alarm contacts fixed in the breaker are used for alarm control

    運行過程中,當斷路器因故障脫扣后,報警觸頭作信號報警控制。
  13. The tma has alarm detect circuit and can report either one lna or both lnas failure

    塔放具備故障檢測能力,當低噪聲放大器工作異常,部分故障或嚴重故障時給出告警信息
  14. As an important executive device, the hydraulic valve ' s safe and stable operation is of momentous significance. so real - time monitoring of the valve ' s running status and dynamically setting of its running parameters are needed. also the valve should alarm and handle failure when error occurs

    各種電液閥作為一類重要的執行器件,保證其安全穩定的運行意義重大,因此需要對閥的運行狀態信息進行有效提取和實時監控,以及在出現故障時報警並做出相應的應急處理。
分享友人