calibration channel 中文意思是什麼

calibration channel 解釋
校準波道
  • calibration : n. 1. 測定口徑。2. 刻度,標度,劃度數。3. 校準;標準化。
  • channel : n 1 水路,水道,渠,溝;海峽;河床,河底。2 (柱等的)槽,凹縫;【機械工程】槽鐵,凹形鐵。3 〈比...
  1. The analysis of channel disaccord calibration discussed in chapter 3

    第三章對通道誤差的校正問題進行討論。
  2. Analysis the cause of channel disaccord of gain and phase, give four methods of gain and phase calibration, computer simulation illustrate the that the methods are effective. in the chapter 4, the basic relation of phase interferometer of one dimension, two dimensions, and the measurement accuracy and the approach of solving the phase ambiguity in the phase interferometers have been discussed in detail

    第四章對相位干涉儀進行了較為詳細和系統的研究,給出一維相位干涉儀的基本關系式,分析了五通道相位干涉儀測向定位演算法及其性能指標,對解相位模糊問題進行了探討,在ccss中模擬了測向演算法,模擬結果證明了演算法的正確性。
  3. During the calibration, a regress - analyse method is used to get the weight of the different channel based on equational coefficient, the weight represents the sensitivity of each channel

    為了提高測量的可靠性和精確性,對9通道數據同時採集,在測試標定時採用回歸分析方法,根據靈敏度得到不同通道的權值。
  4. The scintillation csi was also calibrated with protons of 15, 20, 23 mev. the average energy calibration is 1. 047 mev per channel. energy calibration for heavy ions was completed with multiplication factor 1 / 12. 75

    根據能量刻度實驗的結果,我們對四種帶電粒子進行了測試,方法是首先計算粒子的總能量,確定該粒子所屬的能區並計算e ,根據e一e方法來鑒別帶電粒子的種類。
  5. The irradiation experimental results show that the resolution of thin detector e1 is higher than that of other thick detectors for ex - particles and protons detection. energy calibration for a - particles was completed with multiplication factor 1 / 3. energy calibrations of a - particles in detector e1 and e1, are 0. 107 mev and 0. 123 mev per channel, respectively

    質子能量刻度採用1檔,每道能量h約在0 . 0167mev道,但是在e _ 1探測器中的能量刻度隨著能量的增加略有所下降,這是由於高能質子伴隨有較多的核反應道對粒子探測產生了干擾,從而增加了在e _ 1探測器中的能量沉積道數,使得每道能量略有所下降,另一個因素可能是探測器厚度的不均勻性的影響,但這並不影響對粒子的鑒別。
  6. In this dissertation, researching from the basic concept of large signal network analysis, we discuss the measurement theory and technology of rf network nonlinearity and the characterization technology of intermodulation distortion in detail, and analyse some nonlinear characteristic excited with a one tone or multi - tone, such as am - am, harmonic distortion, intermodulation distortion, adjacent channel power ratio and how to qualitatively analyse nonlinearity of rf network to make the measurement and calibration

    本課題從大信號網路分析的基本概念出發,詳細討論了射頻網路非線性的測量理論和技術以及互調失真表徵技術,分析了在單頻音和多頻音信號激勵下的一些非線性特性,如am - am , am - pm ,諧波失真,互調失真( imd )和臨近通道功率比( acpr )等,以及根據包絡域方法定性地分析射頻微波網路的非線性特性,以此來進行射頻網路的非線性測量和校準。
  7. 6. since the monitor precision of quasi - dynamic calibration system is very important, the model of the four channel electric pressure - measuring system in frequency domain is built up. the cause of variance is analyzed. the error function of the system is defined and the formula of correcting the system error is derived

    6由於落錘液壓動標裝置校準系統的校準壓力監測精度極為重要,本文對四路電測壓力系統進行頻域建模,分析了產生不一致的原因,定義了系統的誤差函數及推導了統一誤差模型的修正公式。
  8. This paper goes on with analysis of the phased array radar calibration theory and compare of different schemes, then the best is adopted. 2 mhz digital circuit mainly composed of dds ( direct digital synthesis ) chip, which carries out the shift of the phase and the limit of the amplitude, has been designed and debugged successfully. it is used to substitute for the conventional phased shift circuit and amplitude limiting circuit which work at the radio frequency, so the all - digital transmit channel of phased shift array radar is achieved

    本論文研究的重點是:針對傳統相控陣雷達系統收發( t r )組件中的移相和限幅功能均在射頻段完成,大膽利用直接數字合成( dds )晶元組成頻率在2mhz左右的數字電路代替傳統相控陣雷達在射頻段進行移相和限幅的電路,從而組成全數字發射通道,使對相位和幅度的控制和調試更方便快捷,並設計具體的電路驗證此方案的可行性。
  9. In experiment, the alignment and calibration to the monochromator were described firstly. then, a gas - flow proportional counter and the multi - channel analyzer ( mca ) are calibrated by the radio isotope source 55fe, and the dead time, counting rate plateau and x - ray linearity have been measured

    最後利用同步輻射光源做激發源,在掠出射方式下研究了si片上不同厚度單層cr膜和雙層fe v膜樣品產生的熒光光強和掠出射角的對應關系。
  10. The energy calibration is around 1. 1 mev per channel for oxygen ion and iron ions when energy deposition is less than 50 mev in each detector

    從重離子的能譜中我們可以看到,在半導體探測器中的能量沉積大於50mev時,將引起電荷靈敏前置放大器飽和。
  11. In the third section, the simulation on music direction finding and the influence that is caused by snr, space between antennae, signal frequency and channel mismatch is analyzed. according to the single known - direction source calibration method, the channel mismatch is calibrated

    第三部分介紹了music測向基本原理,詳細分析了信噪比、陣元間距、通道失配等因素對其測向結果的影響,並利用單信號有源校正方法,對通道失配進行了校正,提高了測向精度。
  12. Calibration factor of a data channel

    數據通道校正系數
分享友人