chromatographic system 中文意思是什麼

chromatographic system 解釋
層析系統
  • chromatographic : 層析的
  • system : n 1 體系,系統;分類法;組織;設備,裝置。2 方式;方法;作業方法。3 制度;主義。4 次序,規律。5 ...
  1. A highly sensitive chromatographic system is desirable particularly for monitoring analyte present in trace concentrations within samples

    高靈敏的層析系統是一個理想的系統,特別對監測存在於樣本追蹤濃度的分析物。
  2. The test samples injected into injection valve are brought into the column by mobile phase ; all ingredients are separated in the column and entered into the tester by order, chromatographic signals of which will be recorded by recorder, integrator or data processing system

    注入進樣閥的供試品,由流動相帶入柱內,各成分在柱內被分離,並依次進入檢測器,由記錄儀、積分儀或數據處理系統記錄色譜信號。
  3. Except for types of stationary phase, components of mobile phase and types of detectors, other prescribed conditions under each type, such as internal radius and length of chromatographic column, brand of stationary phase, carrier granularity, flow speed of mobile phase, as well as proportion, column temperature, volume of incoming samples of different components of mixed mobile phase and sensitivity of detector can be appropriately changed to accommodate different chromatographic system and reach requirements for applicable test of the system

    各品種項下規定的條件除固定相種類、流動相組成、檢測器類型不得任意改變外,其餘如色譜柱內徑、長度、固定相牌號、載體粒度、流動相流速、混合流動相各組成的比例、柱溫、迸樣量、檢測器的靈敏度等,均可適當改變,以適應具體的色譜系統並達到系統適用性試驗的要求。
  4. The use of a mobile phase containing an ion pairing reagent makes it compulsory to rinse the entire chromatographic system with ultra - pure water at the end of the test and to purge the injector during this rinsing operation

    使用含離子對試劑的流動相時,檢驗結束后必須用超純水淋洗整個色譜系統,並在淋洗時清洗進樣器。
  5. When injecting samples, chromatographic column should be completely flushed and balanced with mobile phase ; if the system applicability is not up to regulation, or if filling agents are damaged, replace with new similar chromatographic column for analysis ; if operation according to procedures can not reach scheduled separation due to existence of certain difference between degree of bond of chemically bonded - phase of similar filling agents and performance, another brand of similar chromatographic column can be used for test

    3進樣前,色譜柱應用流動相充分沖洗平衡,如系統適用性並不符合規定,或填充劑已損壞,則應更換新的同類色譜柱進行分析,由於同類填充劑的化學鍵合相的鍵合度及性能等存在一定差異,往往依法操作達不到預定的分離時,可更換另一牌號的同類色譜柱進行試驗。
  6. Polar filler are used in normal phase chromatographic system, among which, silicon gel is the most commonly used

    正相色譜系統使用極性填充劑,常用的填充劑有硅膠等。
  7. Applying micro - column liquid chromatographic system can reduce consumption of solutions and reach the goal of fast separation

    採用微柱液相色譜系統可以減少溶劑的消耗並達到快速分離之目的。
  8. Nonpolar filler are used in reversed phase chromatographic system, of which, octadecylsilane chemically bonded silica is most commonly used, sometimes, octyl chemically bonded silica and other types of chemically bonded silica ( such as cyano chemically bonded phase and amino chemically bonded phase, etc ) are also used as well

    反相色譜系統使用非極性填充劑,以十八烷基硅烷鍵合硅膠最為常用,辛基硅烷鍵合硅膠和其他類型的硅烷鍵合硅膠(如氰基硅烷鍵合相和氨基硅烷鍵合相等)也有使用。
  9. All chromatographic analytical procedures should include system suitability testing and criteria

    所有的色譜分析方法都應當要有系統適應性實驗及相應的合格標準。
  10. System suitability testing is recommended as a component of any analytical procedure, not just those that involve chromatographic techniques

    建議系統適應性實驗應成為所有分析方法的一部分,而不僅僅是色譜分析方法。
  11. This paper introduces the development process and new trends of transformer oil chromatographic analysis technique at home and abroad in terms of the gas circuit system of chromatograph, degassing approach, data processing, diagnostic technique of transformer faults as well as the development and application of chromatograph on - line monitor, etc

    從色譜儀氣路系統、脫氣方法、數據處理及變壓器故障診斷技術和色譜在線監測裝置的研製與應用等方面,介紹了國內外變壓器油色譜分析技術的發展過程及最新動態。
分享友人