condenser flow 中文意思是什麼

condenser flow 解釋
冷凝器水流通道
  • condenser : n. 冷凝器;凝汽器;電容器;聚光器;【紡織;印染】集棉器;搓條機。
  • flow : vi 1 流,流動。2 (血液等)流通,循環。3 流過;川流不息;(時間)飛逝;(言語等)流暢。4 (衣服、...
  1. Two completely different schemes for cooling water flow are obtained by changing the diesel engine ' s water flow from the oil condenser to the water jacket of the cylinder block

    摘要通過改變柴油機從機油冷卻器流入機體水套的水流動方式,得到兩種完全不同的冷卻水流動方案。
  2. By using a same boundary dimensions high efficient and new type copper exchanger substituted carbon steel oil condenser, and increasing flow rate of circulation water to reduce the temperature of freezing oil which feeds into compressor stage, to eliminate the malfunction during compressor operation, and improve running efficiency of the machine

    採取將碳鋼材質的油冷卻器更換成等外形尺寸的高效新型銅管換熱器、增加循環水流量的方法,降低了進入二段壓縮機冷凍油溫度,排除了壓縮機運行中的故障,改善了機組的運行效率。
  3. The plate - tube evaporator, the single back - fin evaporator and the box condenser. after analyzing the physical model and setting up the mathematical model according to the two - phase flow of adiabatic capillary tubes, it also numerically simulates and analyzes the different effects of main parameters on the capillary tube length. based on the heat transfer analysis and counting of thermal insulation layer, the cad system accomplishes the parametric design and drawings of the refrigerator body

    該系統完成了對典型製冷裝置的換熱器部件,如板管式蒸發器、單脊翅片管式蒸發器、箱壁式冷凝器的參數化設計和繪圖;分析了絕熱型毛細管兩相流的物理模型,並建立數學模型,對絕熱型毛細管各主要參數對其長度的影響進行了數值模擬和計算分析;基於對電冰箱箱體絕熱層厚度的傳熱分析和計算,完成了整個箱體的參數化設計和繪圖工作。
  4. No backward flow will occur in the specially designed evaporation chamber of the system. the condenser is built with automatic bubble elimination mechanism

    特殊設計使蒸發室不致有逆流發生,並且,在濃縮過程中有自動消除泡沫之功能。
  5. Therefore, it is necessary to take suitable measures to alleviate the influence of flow deflection on the heat - transfer performance of the condenser

    在管束布置時,應當採取相應措施減小流場偏斜對凝汽器傳熱特性的影響。
  6. Concentric jacket pipe surrounded the test condenser. steam was generated in the boiler, flowed upward to the inlet of connection pipes, then flowed downward into the condenser tube, the cooling water flowed countercurrently through the annulus. the experiment covered the range of the pressure 1. 0 ~ 3. 0bar, heating power 2. 0 ~ 15. 0kw, steam mass flow rate 0. 001 ~ 0. 004kg / s, air mass flow rate 0. 0 ~ 0. 00163kg / s, and cooling water temperature 20 - 60 ?

    在系統壓力為0 . 1 0 . 3mpa ,加熱功率為2 15kw ,蒸汽質量流量為0 . 001 0 . 004kg s ,空氣質量流量為0 . 0 0 . 00163kg s ,二次側冷卻水溫度20 60的范圍內,系統研究了豎直下降管內含有空氣的蒸汽冷凝特性,獲得了不同壓力、不同空氣含量和不同加熱功率下,冷凝段的溫度分佈和局部熱流密度的數據。
  7. Examinations of steady status and analysis of dynamic experiments have been conducted on band - tube evaporator and parallel - flow condenser using r134a refrigerant. the steady examination show that the model error was under the allowable error, the inlet mass and enthalpy disturb experiments indicate that the subsection model, be good at reflecting the change of parameters of the heat exchanger, accord with the basic principle of thermodynamics theory and the actual work status. hence, the subsection simulation model research has important benefits both on theory and engineering application

    在進行模擬試驗時,以使用r134a作製冷劑的管帶式蒸發器和平行流式冷凝器為對象,完成了穩態模擬計算、試驗和動態模擬分析,穩態計算結果和試驗數據對比表明,其誤差在允許范圍內;進口質量和焓值的擾動試驗結果表明:本文所建的區段式換熱器模擬模型,能很好的反映換熱器性能參數的動態變化,與系統熱動力學理論和冷凝器、蒸發器的實際工作過程基本一致。
  8. The flow passage of intermediate - pressure cylinder, as well as the condenser and the vacuum extraction system had also been retrofitted in 2004, the safety and economic behavior of said unit being further enhanced

    2004年又對7號機中壓缸通流部分及凝汽器、真空抽氣系統進行了改造,機組的安全性及經濟性均有了進一步提高。
  9. The research results show that the counter - flow condensers have a better performance than that of other arrangements in single - circuit condensers, and that branch flow should be adopted in multi - rows condensers to decrease the pressure drop and increase the heat transfer capacity, and that the influence of gravity force can not be ignored, and that there must be an optimum refrigerant mass flow which can make the condenser perform best when the air velocity is constant while there must be an optimum air flow which can make the condenser perform best when the refrigerant mass flow is constant

    研究結果表明,單迴路冷凝器中,逆流布置換熱效果最好,叉流其次,順流最差;多排管冷凝器應盡可能採用分流方式,以減小壓降,增強換熱;布置冷凝器流程時,重力的影響不可忽略;當風量不變時,必然存在一最佳製冷劑流量使冷凝器性能達到最佳;當製冷劑流量保持不變時,也相應存在一個最佳風量使冷凝器性能最佳。
  10. To improve the performance of ashp, an improved ashp system is presented. different from the original system, the new one can control the refrigerant flow rate by the sub - cooling of condenser and adjust the sup - heating of the compressor inlet vapor by the heater in accumulator. the simulation shows the new system not only has better dynamic characteristic of frost and defrost of ashp, but also has higher coefficient of performance

    為改善空氣源熱泵機組的結霜除霜動態性能,提出了一種利用冷凝器過冷度來調節製冷劑流量,在氣液分離器里增加電熱裝置保持壓縮機進口過熱度的改進型系統,結果表明這種改進型系統不但可以改善系統的運行性能,同時能改善系統運行的經濟性,為機組的技術升級和產品更新提供了一個新的途徑。
  11. The abnormal conditions of polyester vaccum system such as the frequent exchanging of liquid - ring pump in prepolycondensation, the occlusion of scraped condenser and vaccum atmospheric leg, the eg spray flow decreasing of vaccum injection pump, the working performance on the low side of the injection pump itself were analysed

    摘要對聚酯真空系統的異常情況如預聚液環泵頻繁切換,刮板冷凝器、真空大氣腿堵塞、真空噴射泵eg噴淋流量降低,噴射泵本體工作性能偏低等進行了分析。
  12. To know well the behavior of three - dimensional steam flow and heat transfer in the condenser, a quasi three - dimensional program is adopted to numerically analyse the steam flow field and heat transfer performance of a two - pass power plant condenser numerically

    摘要為了掌握大型電站凝汽器的三維汽相流動與傳熱特性,採用一種準三維數值計算方法對一臺雙流程凝汽器的汽相流動與傳熱特性進行了計算與分析。
  13. On the application of evaporation & condensation, a new open cycle solar still, which is configured mainly by one kind of falling film evaporator, condenser, solar collector and some auxiliary devices, is proposed. parameters affecting system performance, i. e., temperatures and flow rates of moist air, seawater, and cooling water, are analyzed numerically and experimentally

    最後,本文建立了一種以高效降膜蒸發器為核心部件的新型開放循環海水淡化系統,在降膜蒸發器、太陽能集熱器和冷凝器等部件數學模型基礎之上,建立了合理的系統模型,通過數值模擬對空氣、海水、冷卻水等有關參數對淡水產量的影響進行了分析。
  14. Vibration induced by double - segmental baffles and two - phase flow in condenser

    冷凝器中弓形折流板結構與兩相流誘發的振動
  15. Meanwhile, in a distributed parameter approach a steady - state model of condenser and evaporator has also been established in the form of concentric counter - flow heat exchangers

    採用分佈參數法,建立了復合螺旋套管式冷凝器和蒸發器的穩態模型,並編制了冷凝器和蒸發器的設計和模擬軟體。