differential fault 中文意思是什麼

differential fault 解釋
差動斷層
  • differential : adj 1 差別的,區別的;特定的。2 【數學】微分的。3 【物、機】差動的,差速的,差示的。n 1 (鐵路不...
  • fault : n 1 過失,過錯;罪過,責任。2 缺點,缺陷,瑕疵。3 (獵狗的)失去嗅跡。4 【電學】故障,誤差;漏電...
  1. On the basis of this equation, the general differential equations of coupled bending, torsional and pendular nonlinear vibration about rotor with unbalance character and rubbing character are deduced. the bifurcation and chaos behavior especially the influence on bifurcation and chaos behavior of impact and rubbing fault rotor system

    應用數值方法研究了碰摩轉子的彎扭擺耦合振動相應的復雜動力學行為,重點研究了轉子轉速、偏心量等系統參數對碰摩轉子彎扭擺耦合振動的分岔和混沌行為的影響以及扭轉振動和擺動振動對彎曲振動的影響。
  2. Along fault zones in particular, displacement may occur by slow, secular, differential slippage as well as by sudden rupture.

    特別是沿著斷層區,位移既可能以緩慢的,持久的、有差異的滑動發生,也可能以突然破裂發生。
  3. At present, differential protection is often used as the main protection for traction transformers. however, the existing of certain factors, such as magnetizing inrush, over - excitation, ct saturation and mismatching of ct ratio, will result in that it is hard to distinguish state current and fault current, and differential protection misoperation or maloperation, then secure operation of electric railways system will be threatened

    目前,牽引變壓器通常採用差動保護作為主保護,但是在某些因數的影響下差動保護並不能準確的區分牽引變壓器內部故障或非內部故障,如故障電流與變壓器處于勵磁涌流、過勵磁, ct飽和及ct變比不匹配等情況下的狀態電流就很難準確的區分,可能造成保護誤動或拒動,從而危及整個鐵道電氣化系統的安全運行。
  4. The safety of transmission line plays a important role in power system safety it is not only the requirement of ensure supply power reliability, but also the necessary precondition of enhance power system stabilization, to remove faulty line quickly and accurately, also keep non - faulty line continuous work when some transmission line faults current differential protection is a kind of simple, reliable and good - selective protection manner to any variety of transmission lines, power system development needs current differential protection apply to transmission lines, moreover the advancement of electric and communication technology enable current differential protection apply to transmission lines firstly, the paper discusses, analyses the research and application transmission line protection in detail, compare the principle and realistic presupposition of general line pilot protections secondly, because conventional current vector differential protection are influenced easily by load current and transitional resistance, in order to at the same time quicken protection act, the principle and criterion include work characteristic of differential protect based on fault component sampled values are studied, results shows that differential protect based on fault component sampled values excels general vector current differential protection in reliability, sensitivity and anti - saturation of current transformer in addition, synchronous current sampling methods at all terminals of line is analyzed and estimated lastly, the principle and criterion. also device design about current sampling values differential protection based on optical fiber communication, which apply to short transmission lines are concretely investigated,

    基於基爾霍夫定律的電流差動保護無論對於何種形式的輸電線路都是一種簡單、可靠、選擇性強的保護形式,電力系統的發展使得電流差動保護應用於線路保護成為需要,而電子、通信技術的發展使得電流差動保護應用於輸電線路成為可能。首先,本文對目前線路保護的研究和實際應用情況進行了討論和分析,比較了常用線路縱聯保護的實現原理和實現條件及優缺點。其次,針對常規相量電流差動保護易受正常負荷電流和故障過渡電阻影響的缺點,同時為加快差動保護的動作速度,對基於故障分量瞬時采樣值電流差動保護的原理、判據、動作特性等作了討論和分析,結果表明基於故障分量瞬時采樣值電流差動保護在可靠性、靈敏度、抗電流互感器飽和方面明顯優于常規相量電流差動保護,對電流差動保護各端的同步采樣方法和數據通信也進行了分析和評價。
  5. How to discriminate between internal fault and magnetizing inrush current is the difficulty of transformer protection when apply differential relay

    變壓器主保護選擇差動在原理上存在不足,帶來的問題就是如何準確鑒別勵磁涌流與內部故障,這也是目前變壓器保護的難點。
  6. Depositional cycles on basin scale have been interpreted as the result of depositional response to tectonism such as episodic rifting, polyphasic compressive flexural subsidence and reversion, and differential subsidence of fault blocks ; while the formation of high frequency sequences was attributed to variation in lake level and sediment supply

    盆地規模的沉積旋迴多是盆地幕式裂陷、多幕擠壓撓曲沉降、多期構造反轉、斷塊差異沉降等構造作用的沉積回應;高頻層序單元的發育則主要與湖平面和沉積物供給量的變化有關。
  7. This paper analyzes detailedly the principles on distributed busbar protection - current instantaneous value differential method, impedance method, and put forward the new method of current fault component phase method, then compares with these methods

    本文詳細分析了分散式母線保護中的原理?瞬時值電流差動法、阻抗法,提出了電流故障分量相位法的新方法,將這幾種方法進行比較。
  8. Even if the fault spread from external fault zone to internal fault zone, the differential protection can avoid misoperation. main criterion of protection is composite - percentage current differential algorithm according to every sampled value, which can accelerate the protection ' s trip, reduce large amounts of calculation and have strong stability to ta saturation

    本文採用基於采樣值的比率制動式電流差動保護演算法作為保護的主判據,可以明顯提高保護動作速度和減少計算量;具有較強的抗ta飽和能力,在區內故障時無制動,區外故障時有極強的制動特性。
  9. Abstract : in this paper, the setting scheme of the current differential protection based on sampled values using fault component is investigated. the setting schemes of the resistance coefficient and the least trip differential current are discussed in detail. the probable protection setting values for the hv transmission lines are described. it testifies the feasibility for the applications of the protection to the hv transmission lines

    文摘:對基於故障分量的采樣值電流差動保護制動特性曲線的整定方法進行了研究,詳細討論了其制動系數和最小動作電流的整定方法,同時對該保護在輸電線路中的應用進行了初步的估算,說明了該保護的優異性能。
  10. Considering the characteristics of shunt reactors, this paper proposes an accurate fault location algorithm based on differential sequence component network, which only uses the currents at two terminals of a transmission line

    採用基於反序網的雙端量演算法進行故障測距,並根據並聯電抗器的特點消除其影響。
  11. In himalayan, the first era ( 45ma ) the basin is titled ; the second era ( 23ma ) it is differential uplift and denude ; the third era it is brittle defonnation. in eastern ore belt, ore - controlling is mainly strike - slip fault and fold ; but in western ore belt, it is block

    喜馬拉雅運動第一期45ma盆地掀斜;第二期23ma以差異隆升剝蝕為主;第三期4ma為脆性變形期,東礦帶近盆邊以走向斷裂及褶皺控礦為主,西礦帶為斷塊控礦。
  12. In order to improve the behavior of transformer protection that is incomplete at present in distinguishing magnetizing inrush current from fault current, the paper puts forward a kind of new principle of transformer differential protection after analyzing the characteristic of magnetizing inrush and active power consume of transformers. this protection uses differential protection based on positive sequence active power as a criterion to discriminate internal faults from magnetizing inrush, and ratio restraint differential current protection as a signal to touch off the protection

    針對當前電力系統中變壓器保護由於勵磁涌流鑒別理論不完善而導致的誤動率相對較高的問題,論文在分析了變壓器勵磁涌流特性和有功損耗的基礎上,提出了用變壓器正序有功功率差動作為區別勵磁涌流和故障電流的判據,並以成熟的比率制動差流保護作為內外部故障判據的變壓器主保護。
  13. With a differential accumulation analysis of the fault closeness and the difference of faulted reservoir in beitang depression, it is suggested that ( 1 ) an inactive fault in clastic sequence may mainly restrict hydrocarbon migration ; ( 2 ) undercompacted shales with overpressure can lead to strongly restricting hydrocarbon migration along faults ; ( 3 ) hydrocarbon segregation associated with fault traps more probably takes place in undercompacted zone with abnormal hydropressure

    通過黃驊坳陷北塘凹陷斷層的封閉性及斷層油氣藏差異聚集分析,表明斷層在活動停止期主要起封閉作用,但在正常壓實層序段仍有少量輕組分的烴類沿斷層發生運移而引起差異聚集;而在欠壓實帶,異常高孔隙流體壓力使斷層在縱向上具有很強的封閉性。
  14. The possibility of shaft damage led by coupled resonance is litter. useful information for fault diagnosis is provided by the coupled characteristics. the differential equations of coupled vibrations for rubbing rotor are established

    彎振和扭振通過質量偏心發生耦合,由彎扭耦合共振而導致轉子損壞的可能性很小,但這些耦合特徵為轉子的故障診斷提供了有益的信息。
  15. This paper offers a heuristic search algorithm which is relative reduce by differential matrix calculating. this algorithm can quickly reduce fault knowledge base to deduce the east decision rule

    摘要本文給出用差別矩陣計算相對約簡的一種啟發式搜索演算法,能快速約簡故障知識庫,導出最小決策規則。
  16. It is constructed that radial impact and rubbing dynamics differential equations of the rotor system having the nonlinear rigidity on the unsteady and non - linear oil film. the bifurcation and chaos behavior of impact and rubbing fault rotor system caused by the parameters of nonlinear rigidity, rotor rotating speed, eccentric mass is analyzed, in the numerical value analysis method. the bifurcation diagrams, maximum lyapunov exponent diagrams, poincar maps, phase plane portraits, trajectories of journal center, time - history curve, amplitude spectra diagrams of the rotor motion are used

    ( 2 )建立了具有非線性剛度的轉子系統在非穩態非線性油膜力作用下的徑向碰摩動力學微分方程,並應用含高階余項的非線性動力方程的線性化數值法研究了此類系統響應的復雜動力學行為,利用轉子響應的分岔圖、最大lyapunov指數曲線、 poincar截面映射、時域波形、相軌線、軸心軌跡、幅值譜等圖形分析了系統響應的周期運動、擬周期運動、倍周期分岔、混沌等運動形式的轉化與演變過程,重點研究了非線性剛度、轉子轉速、偏心質量等系統參數對碰摩故障轉子系統的分岔和混沌行為的影響。
  17. In fault state, a double circuit transmission line can he decoupled into common sequence component network and differential sequence component network

    由於並聯電抗器的安裝,直接測取雙回線兩端母線處的電壓及線路流過的電流進行測距,必然會引起誤差。
  18. The differential relay compares the currents and picks up when there is a difference in the two, which signifies a fault in the zone of protection

    差動繼電器對電流進行比較,如果存在不同則表示受保護區域內有故障存在。
  19. Block - fault differential uplift

    斷塊差異上升
分享友人