flow-after-flow test 中文意思是什麼

flow-after-flow test 解釋
流量調整試井
  • flow : vi 1 流,流動。2 (血液等)流通,循環。3 流過;川流不息;(時間)飛逝;(言語等)流暢。4 (衣服、...
  • after : adv 在後;繼后;后來。 follow after 跟著。 look before and after 瞻前顧后,前思後想。 soon after ...
  • test : n 1 檢驗,檢查;考查;測驗;考試;考驗。2 檢驗用品;試金石;【化學】試藥;(判斷的)標準。3 【化...
  1. Common test methods for insulating and sheathing materials of electric cables. part 4 : methods specific to polyethylene and polypropylene compounds. section one : resistance to environmental stress cracking - wrapping test after thermal ageing in air - measurement of the melt flow index - carbon black and or mineral filler content measurement in pe

    電纜絕緣和護套材料通用試驗方法第4部分:聚乙烯和聚丙烯混合料專用試驗方法第1節:耐環境應力開裂試驗-空氣熱老化后的卷繞試驗-熔體指數測量方法-聚乙烯中碳黑和或礦物質填料含量的測量方法
  2. Pilot - scale experimental results showed that, comparing to conventional gravity filtration, the up - flow filtration has greater capacity in containing removed suspended solid and producing filtrate under the test conditions. coarse media with particle diameter ranging 0. 63 - 2. 00mm were used in order to apply relatively higher backwash rate of 21 l / ( m2. s ) for achieving better media clean - up after a filtration run. under the test conditions, the media thickness ranging 82 - 85 iron, water temperature ranging 6 - 27, and influx turbidity of 30 ntu, it achieved the results of the average filtration rate ranging 16 - 18 m / h, the average effluent turbidity of 1 ntu, and action cycle ranging 14 - 24h

    中試研究結果表明,粗石英砂濾料上向流過濾比傳統的重力流過濾具有更大的含污能力和產水量,為適用較高的反沖洗強度( 21l ( m ~ 2 ? s ) )以便濾料清洗更干凈,採用粒徑范圍為0 . 63 2 . 00mm的粗石英砂濾料,濾層厚82 85cm ,水溫6 27 ,進水濁度為30ntu左右等情況下,能獲得平均濾速為16 18m h 、平均濾后水濁度為1ntu左右、周期達14 24小時的好效果。
  3. Productive durability test and oxygen transfer performance test in clean water per diffuser for seven kinds of diffusers were studied respectively in this paper, and serving diffusive area, air flow, varied resistance, varied resistance after stopping air flow, diffusive strength were also investigated in the productive testing period

    摘要對7種曝氣器產品分別進行了單盤耐用性生產試驗、單盤清水充氧性能試驗以及對在大生產試驗期間的服務面積、供氣量、阻力變化、停氣后阻力變化、曝氣強度等方面進行了測試對比工作。
  4. Common test methods for insulating and sheathing materials of electric cables - part 4 : methods specific to polyethylene and polypropylene compounds - section 1 : resistance to environmental stress cracking - wrapping test after thermal ageing in air - measurement of melt flow index - carbon black and or mineral filler content measurement in pe

    電纜絕緣和鎧裝材料通用試驗方法.第4部分:聚乙烯和聚丙烯復合物專用方法.第1節:耐環境應力裂化試驗.空氣中熱老化后的纏繞試驗.溶體流動指數的測量. pe中炭黑和或礦物填充料的含量測量
  5. Associated tightly with the stokes measured in small capacity current breaking and short - circuit breaking test duty t100a ( short arc, middle arc and long arc ), the electric field distributions 3 ms after current zero have been calculated. the cold gas flow field corresponding with small capacity current breaking is calculated. based on the results derived from one - dimensioned gas flow field simulation, the two - dimensioned gas flow fields corresponding with short - circuit breaking test duty t100a ( short arc and middle arc ) are calculated as well

    本文採用與試驗緊密結合的方法,在給定機械行程曲線的基礎上對三峽工程中採用的550kvsf6斷路器在開斷小電容電流、短路開斷方式5短、中、長燃弧電流過零后3ms內滅弧室二維靜電場分佈進行了分析計算;對該斷路器開斷小電容電流時近似的冷態場進行了二維模擬分析計算;在對短路開斷方式5短、中、長燃弧一維氣流場進行分析計算的基礎上進一步採用一維氣流場和二維氣流場相結合的方法,對該斷路器開斷方式5短燃弧和中燃弧對應的二維熱態場進行了分析計算。
  6. This test shows that after the 20 minutes of exposure of the human subject to the mobile phone radiation the blood flow pulsation “ jumped ” from the average range of 1 cm / sec ? 6. 6 cm / sec ( fig. 1 ) to the much higher average range of 0 cm / sec ? 14. 4 cm / sec ( fig. 2 )

    本試驗顯示人類實驗對象暴露在行動電話輻射20分鐘之後,血流脈動自1厘米秒66厘米秒(圖1 )之平均范圍比較跳到0厘米秒14 . 4厘米秒(圖2 )之平均范圍高。
  7. After deriving the governing equation of motion of these dampers and the theoretical model, we simulated the damping force of the dampers under different electric field strength conditions, and used an electrical hydraulic servo dynamic testing system to test flow mode er damper and mixed mode er damper

    在不同電場下,模擬阻尼器的阻尼力特性,並使用電液伺服動態測試系統測試流動模式電流變液阻尼器及混合模式電流變液阻尼器。
  8. About the problem of potential interference between wlan and medical devices, this paper provide a series of test methods, requirements, flow and the evaluation on medical devices working status, after analyzing related poten - tial interference factors, with the reference of international medical emc standards, and the experience of tests in the overseas hospitals

    關于無線局域網設備是否會對醫療設備產生不良干擾問題的測試研究方案,測試參考了國際上和醫療無線干擾相關的標準,並借鑒國外一些醫院的測試經驗,在分析了無線局域網路對醫療設備潛在干擾的相關因素基礎上,總結了一系列的測試方法和要求,並描述了測試流程及對醫療設備性能的評估。
分享友人