flow-test line 中文意思是什麼

flow-test line 解釋
測流管線
  • flow : vi 1 流,流動。2 (血液等)流通,循環。3 流過;川流不息;(時間)飛逝;(言語等)流暢。4 (衣服、...
  • test : n 1 檢驗,檢查;考查;測驗;考試;考驗。2 檢驗用品;試金石;【化學】試藥;(判斷的)標準。3 【化...
  • line : n 1 線;繩索;釣絲;測深度用繩,捲尺。 a fishing line 釣魚線。 be clever with rod and line 會釣魚...
  1. The author also uses the computation by tabulation to test the to all kind of possible planning schema of section station, and figure out the cost of transportation by the component of car flow from the viewpoint of economical evaluatioa at last, a feasible planning schema about section station of xiang - shi line is drawn

    並採用行車組織中慣用的表格計演算法分析驗證各種區段站設置方案的優劣,又從經濟評價的角度計算各種區段站設置方案條件下可能產生的有調中轉車流和無調中轉車流的數量,計算出各種方案的運輸成本費用,進一步論證襄石線區段站設置方案的可行性。
  2. This new technology changes from the traditional method by which the induced and compressor wheel separately are designed and produced to a new one by which the one - piece compressor is designed. on the basis of this new technology and the optimum blade profile, the performance of both the compressor and the turbocharger is largely improved. through the heating power calculation of the compressor, the analysis of the surge and the block of the compressor, the test - bed performance test of the turbocharger, the matching test of turbocharger and diesel engine, the propulsion test of the turbocharger on plateau condition, it is proved that the newly - designed compressor not only has high efficiency, but also improves the flow distribution in the high efficiency area so that the propulsion line can run through the high efficiency area

    主要內容包括:提出一種全新的壓氣機葉輪技術和概念,這種技術將傳統的導風輪和壓氣機分開設計、單獨加工改為整體設計、整體加工的單體葉輪;從增壓器與柴油機配機計算所得出的基本參數出發,通過對壓氣機進行熱力計算,確定壓氣機的基本結構參數;再對葉型以及葉輪輪廓與葉輪罩殼的配合間隙進行優化,對新設計的壓氣機進行喘振和堵塞分析;通過增壓器平臺性能試驗,驗證了新設計的壓氣機的性能水平得到了較大的提高,達到了提高增壓器的整體性能水平的目的;通過增壓器與柴油機配機試驗、以及增壓器用於高原條件下的牽引試驗,驗證了新設計的壓氣機不但具有高效率,還改善了高效率區的流量分佈,使牽引特性線貫穿高效率區。
  3. Abstract : this article lists some notices of the measurement points and their importance in cleanrooms, content focus on : indoor temperature measurement, humidity survey, exhaust air flow measurement, production line velocity measurement, inside and outside pure room differential pressure survey and the related test equipment for those measurement mentioned above

    本文主要介紹了潔凈室里需要注意的幾個測量點和它重要性,內容包括:室內的溫度測量、濕度測量、送風量和排風量的測量、成品生產線上的微風速測量、潔凈室內外壓差測量等,以及與之配套的測試儀器選擇方法。
  4. The prototype test results indicate : voltage mode and current mode ac - ac mode ac / ac converters with high frequency link have the advantages such as high frequency electrical isolation. simple topology, two - stage power conversions, high power density, bidirectional power flow, good line current waveform, no audio noise, high converting efficiency, and high input power factor etc. this kind of converter lay the key technical foundation on new type regulated sinusoidal ac power supply, electronic transformer, ac regulator, and wave converter etc

    試驗表明,這類變換器具有高頻電氣隔離、電路拓撲簡潔、兩級功率變換( lfac hfac lfac ) 、功率密度高、雙向功率流、無音頻噪音、變換效率高、網側功率因數高等優點。為新一代正弦交流穩壓器、電子變壓器、交流調壓器、同頻波形變換器的實現奠定了關鍵技術基礎。
  5. In the multiple - layered test for injection wells, a lot of pressure falloff curves in the single layers are hard to show a radial flow straight line due to the perturbative phenomena of multilayer reservoir, low permeability or short test time

    摘要在注水井分層測試中,由於油藏的低滲透性或者測試時間相對較短等原因,各層的壓力恢復曲線難以出現徑向流直線段。
  6. Network test shows that the flow line distribution are continuous and dense, so it is considered to be the reason that forged gears have higher strength and longer life

    網格試驗顯示,塑性加工的螺旋傘齒輪金屬纖維連續而緻密,揭示了塑性加工齒輪強度高和使用壽命長的原因。
  7. The national fire protection agency ( nfpa ) guidelines require a confirming flow test to be conducted whenever a " main line " valve such as the shutoff valves or a backflow assembly have been operated

    美國國家防火協會( nfpa )指導原則要求對于主管線上運行的閥門,如關閉閥或防迴流閥總成,必須進行流量測試。
  8. Fire protection system installations : the national fire protection agency ( nfpa ) guidelines require a confirming flow test be conducted whenever a " main line " valve such as the shutoff valves or a backflow assembly have been operated

    消防系統安裝:美國國家消防局( nfpa )指導原則要求只要是「主管線」上已經運行的閥門,如關閉閥或防迴流閥總成,都需要進行流量確認檢測。
  9. Fire protection system installations : the national fire protection agency ( nfpa ) guidelines require a confirming flow test be conducted by a certified tester whenever a " main line " valve is installed, such as a shut - off valve or a backflow preventer

    消防系統安裝:美國全國消防局( nfpa )指導方針要求在安裝「主管道」閥門時要由有資格證書的檢驗員對關閉閥或防迴流閥進行流量檢測。
  10. Its test results indicate : voltage mode inverters with high frequency link have the advantages such as high frequency electrical isolation, simple topology, two - stage power conversions, high power density, bidirectional power flow, good line current waveform, low audio noise, high converting efficiency, and high input power factor etc. this kind of converter lay the key technical foundation on new type high power density, high efficiency and low cost asi

    設計的1kva270v 10 % dc / 115v400hzac單極性移相控制雙向電壓源高頻環節逆變器原理試驗表明,這類逆變器具有高頻電氣隔離、電路拓撲簡潔、兩級功率變換( lfac / hfac / lfac ) 、功率密度高、雙向功率流、音頻噪音低、變換效率高、網側功率因數高等優點,為新一代高功率密度、高變換效率、低成本航空靜止變流器奠定了關鍵技術基礎。
分享友人