  1. In this paper, the application of centum cs1000 of yokogawa in the benzene chloride production is discussed. the system struct, software and hardware of the engineering workstation and human interface station, system configuration, safety property and grounding are also studied

    本文以實際工程為背景,論述了橫河的centumcs1000在氯化苯生產過程中的應用,對系統選型、工程師站和操作員站軟硬體配置、現場控制站配置、系統組態、安全性、接地等問題進行了一定的探討。
  2. For the instrument system, we introduce effective steps and technique of screen or grounding screen that can restrain the great mass of interference

    針對儀表系統,介紹了能有效抑制絕大部分類型干擾的屏蔽和屏蔽接地措施和技術。
  3. But when fault was occurred, sometimes there would be great loss. for the reason, the paper put forward a microcomputer bus protection scheme suit for mv or lv power system with low current grounding based on the great researching about the working theory of current bus protections and the characteristic of mv or lv system with low current grounding. based on it, the paper has designed the platform of the hardware and the software programs

    針對國內目前中、低壓電網大都未裝設母線保護裝置,發生故障不能及時切除時造成很大損失的狀況,本文在廣泛研究當前主流的母線保護動作原理並認真分析了中、低壓小電流接地系統特點的基礎上,提出了一套適合中、低壓微機母線保護裝置的研製方案,並據此選擇、搭建了硬體平臺,設計了軟體功能程序。
  4. An external lightning protection system ( lps ) means, to me, that lightning rods, related cabling and a building grounding method are already in place

    按我的理解,外部雷擊防護系統( lps )所指的是已經在位的避雷針、相關的引線導體及建築物的接地方式。
  5. Mjc : an external lightning protection system ( lps ) means, to me, that lightning rods, related cabling and a building grounding method are already in place

    按我的理解,外部雷擊防護系統( lps )所指的是已經在位的避雷針、相關的引線導體及建築物的接地方式。
  6. According to the quickly adjustable characteristic of the peterson coil grounding system, this dissertation proposes a new control strategy. when the system is in operation, the strategy can limit the series resonance over - voltage by using the off - resonance method. when fault occurs, the strategy can conveniently suppressing arc by rapidly adjusting the inductance value of the peterson coil to the point, which the resonance with grounding capacitance of the power network is occurred

    依據可控硅控制消弧線圈接地系統的快速可控性,一改傳統的電網正常運行時調節消弧線圈接近於全補償的預調諧方法,提出正常運行時採用脫諧方法抑制串聯諧振過電壓;故障時立即調節消弧線圈電感量達到與對地電容諧振,以利熄弧的新型調節原理和方法。
  7. New designed auto tracing arc eliminating device based on this technique contents more technology, which has sample circuit, wide tuning scope, quick response and low noise. this paper firstly introduces neutral grounding histroy. by analyzing the syntony grounding theory, the transient and stable process of one - phase grounding fault, the threaten to secure run of power system and the importance of exact compensation for capacitive current are cognized

    論文中首先介紹了中性點接地方式的發展過程,通過對諧振接地原理和單相接地故障的暫態、穩態分析,認識到接地故障對系統安全運行的危害,通過消弧線圈對接地電容電流的迅速準確補償是減小故障危害的最主要手段。
  8. The single - phase grounding fault frequently occurs in neutral ungrounded system, the fault line and fault location must be found to avoid a phase - to - phase short as soon as possible

    單相接地故障在小電流接地系統中出現的比較頻繁,此時必須盡快找到故障線路以及大致的故障點,以避免兩相對地短路。
  9. Grounding resistance is important technical parameter of grounding system

    接地電阻是發、變電站接地系統的重要技術指標。
  10. Application of signal injection method for fault line selection and fault point location in resonance grounding system

    選線定位原理在諧振接地電網中的應用
  11. The reasearch about both function device of compensate and line selection about single - phase grounding capacitire current for small current grounding system

    小電流接地系統單相接地電容電流補償與選線雙功能裝置的研究
  12. The results show that the vertical grounding electrodes can effectively decrease grounding resistance, step and touch voltages of the grounding system and reduce the influence of seasonal factors on the grounding system

    分析表明,增設垂直接地極能有效減低接地系統的接地電阻、減小發變電站的接觸電壓和跨步電壓、減小季節因素對地網安全性的影響。
  13. It includes four criterions of locating fault point ? “ transient zero sequence current amplitude law ”, “ stable base wave zero sequence current phase law ”, “ stable seventh harmonic zero sequence current phase law ” and “ s injection law ”. pointing out how the law locate the fault point to minimal fault section by applying these criterions gradually. the law will not only make up the blemishes existing in current methods for single - phase fault location in small current grounding system, but also locate the fault point to minimal fault isolating unit on fault line

    該方法通過將所包含的四個定位判據- 「暫態零序電流幅值法」 、 「穩態基波零序電流方向法」 、 「穩態7次諧波零序電流方向法」和「 s信號注入法」 -進行有選擇地遞進使用,不僅有效彌補了目前已有小電流接地系統單相接地故障選線的缺陷,更將故障定位在故障線路最小故障區段。
  14. Power supply : specialized in the design of h. t l. t substation and grounding system

    供電設計組:高低變配電站設計工程防雷系統。
  15. The research shows that the protection of the industrial control system are not only need the external lightning protection system such as air terminals, down conductors and grounding system, but also need the internal lightning protection system such as equipotential bonding, shielding and surge protection of information system and electrical system

    經研究,對工業控制系統的防雷保護不僅要做好接閃器,引下線,接地體等基本的外部防護,還要做好等電位聯結,屏蔽,信號系統和電源系統的電涌保護等相關內部防雷措施。
  16. However, the grounding system becomes saturated as more vertical grounding electrodes are arranged in a substation with a fixed size

    但在有限的地網面積范圍內布置過多的垂直接地極時,垂直接地極的效果將趨于飽和。
  17. Improvement of capacitance current and reformation of grounding system for mine 6kv electric network

    電網電容電流治理與接地系統改造
  18. Numerical simulation of grounding parameters in the substation grounding system

    變電站接地網數值計算
  19. The principle of the fault distance measurement for small current grounding system by injecting dual frequency signal are discussed from many aspects such as the method and the characteristic of the signal, the test of the signal, the method of the line select, the algorithm of the fault distance measurement, and the method of the fault location, etc. the task adopts this kind of principle, in which the signal injection is completed by the coupling between the power source and the pt

    在詳細地說明以上三種測距演算法的基本原理后,分析各種演算法的優缺點,從注入信號的方法、特徵,注入信號的檢測,接地選線的方法,故障測距的演算法,及故障定位的方法等多個方面,論述了本課題採用的應用於小電流接地系統的雙頻信號注入式測距原理。其中,信號的注入由功率源通過電壓互感器( pt )耦合來完成。
  20. The small current neutral grounding system is a kind of system without neutral grounding, in most of which the neutral point connects to ground through a reactor

    小電流接地系統是指中性點不直接接地系統,其中大多數採用中性點經消弧線圈接地方式。