heat input rate 中文意思是什麼

heat input rate 解釋
供熱率
  • heat : n 1 熱;熱力;熱度;熱量。2 體溫;發燒。3 (氣候的)高溫,暑氣。4 【冶金】熔煉的爐次;裝爐量;一...
  • input : n. 1. 【電學】【自動化】輸入;輸入端。2. 輸入電路,輸入信號,輸入功率[電壓]。3. 放入物,投入的資金。vt. ,vi. 把(數據等)輸入計算機。
  • rate : n 1 比率,率;速度,進度;程度;(鐘的快慢)差率。2 價格;行市,行情;估價,評價;費,費用,運費...
  1. It can be seen that fire growth and heat release rate curve can be obtained through the calculation of fire load and the estimation of fire spread, which can provide the input for the latter work and enhance the efficiency of fire protection analysis observably

    可以看出,根據火災荷載的計算和火災蔓延可能性的討論,得到火災發展的變化情況和熱釋放速率曲線,能夠為之後的工作做好前期準備,同時顯著提高這項工作的效率。
  2. This experiment include many contents, in a word, that is summer condition experiment, winter condition experiment > summer - winter transition condition experiment and winter - summer transition condition experiment, furthermore summer condition experiment still include flux changing experiment and winter condition experiment still include thermal balance experiment this article dealt with the data of the test, calculating out energy absorbing ( energy discharging ) of buried pipe in winter condition ( summer condition ), input power of heat pump x heat exchanging of piece buried pipe length x co - efficiency performance ? op ( energy efficiency rate ? er ) and average heat exchanging coefficient ; in additiont this article compares the inlet water temperature and outlet water temperature of underground the first layer and the second layer buried pipe when heat pump was running, the results are that the heat exchanging ability of the second layer buried pipe outgos the first layer buried pipe, and heat exchanging is more stable ; and still analyse earth temperature resuming in the transition season. the results are earth temperature resume fast in the first week when the heat pump runs off

    本文測試內容相當多,概括地說就是四個工況的測試,即夏季製冷工況的測試、冬季供熱工況的測試、夏?冬過渡季測試和冬?夏過渡季測試;另外在夏季工況的測試中還進行了變流量測試,在冬季工況的測試中還進行了熱平衡測試。本文對測試數據進行了處理,計算出了冬(夏)季工況埋管吸(放)熱量、熱泵空調器供熱量(製冷量) 、熱泵空調器輸入功率、埋管單位管長換熱量、供熱性能系數(製冷能效比)和平均傳熱系數等;另外,還比較了熱泵運行時地下一二層埋管進出水溫度變化情形,得出地下二層埋管換熱能力優于地下一層埋管,且換熱很穩定;並分析了過渡季地下一二層埋管溫度恢復情形,得出熱泵系統停機一周內地溫恢復特別快。
  3. Green " s theorem is employed to find the quantity relationship among the constraints of heating rate, dynamic pressure and lift in reentry flight. the paper deduced the approximate solution of the optimal aeroassisted coplanar trajectories under the three typical constraints. the performance index to be minimized are either heat input, the total dynamic pressure, time during the atmospheric flight, the time integral of the square of the path inclination ; or maximize the time of flight during the atmospheric portion of the trajetory. an important conclusion is firstly obtained : under the three constraints above, the optimal aeroassisted coplanar transfers with the first forth kinds payoffs have the same optimal control laws

    採用格林函數法,給出了同一平面氣動力輔助變軌飛行的3種過程約束(氣動加熱率、動壓、升力約束)條件之間關系的近似定量描述形成的飛行包絡線.由此求解了航天器同時受3種約束條件時,各種性能指標下的同一平面氣動力輔助變軌軌跡的近似解及相應的最優控制規律.文中對近似解與控制規律的內部結構作了細致的分析,得到了一些有益的結論
  4. The heat flux in gauss distribution heat input model employed in numerical simulation of line heating is determined by heating efficiency and heating radius that are determined by acetylene flow rate in turn

    摘要水火彎板數值計算所用高斯分佈的熱源模型中熱流密度由熱效率和熱源半徑決定,而熱效率和熱流密度主要取決于乙炔流量。
分享友人