line-to-neutral 中文意思是什麼

line-to-neutral 解釋
從導線到中性點的
  • line : n 1 線;繩索;釣絲;測深度用繩,捲尺。 a fishing line 釣魚線。 be clever with rod and line 會釣魚...
  • to : adv 到某種狀態;〈特指〉到停止狀態;關閉。 ★也常和動詞結合,略去其後賓語,而構成成語: The door i...
  • neutral : adj 1 中立的;中立國的。2 不偏不倚,公平的;中庸的;中間的;不倫不類的,不明確的;不鮮艷的,暗淡...
  1. The single - phase grounding fault frequently occurs in neutral ungrounded system, the fault line and fault location must be found to avoid a phase - to - phase short as soon as possible

    單相接地故障在小電流接地系統中出現的比較頻繁,此時必須盡快找到故障線路以及大致的故障點,以避免兩相對地短路。
  2. Through analysising the characteristics of the power system with floating neutral point deeply, the paper puts forward a new plan of single - phase to ground fault line selection on the base of s ' s signal injecton method and gives the hardware and software design. in this design, the high speed sampling and data processing is carried out through using dsp processor ; the large electrice current is drived through the application of a high - performance audio power amplifier and transformer ; the communication between host computer and detectors is realized through rs485 bus technology ; the difference multilevel frequency - selected amplifier is designed and the feeble signal of space is sampled on the base of the theory of magnetic induction ; the interface between dsp and exterior chip and rs485 interface logical is designed through using fpga ; the using of lcd module and keyboard interfacing chip makes the interface between human and machine ; the programme of host computer and detectors is designed through using blocking design method

    在本設計中,採用高速的dsp處理器,實現了對故障特徵信息的高速採集與處理;採用大功率的功放晶元與變壓器配合的方法,實現了大電流信號的驅動輸出;採用485總線技術,組建了裝置主機與多探測器之間的主從式通訊網路,實現了多干擾條件下裝置主機與多探測器的可靠通訊;設計了差分式多級選頻放大電路,採用磁感應的方法實現了對空間微弱信號的接收;利用fpga技術,實現了控制器與多外設的介面及數字信號的串並轉換;採用了先進的lcd液晶顯示模塊及鍵盤介面晶元,設計了人機信息交互的介面;採用了模塊化的軟體設計方法,開發了裝置主機及探測器的軟體程序。
  3. The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance

    爭議點主要是在10kv電網接地故障的形式、消弧線圈接地的應用范圍、兩種運行方式供電可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以電纜為主的城區10kv電網中性點接地方式的選擇問題進行研究。論文首先對10kv電網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變電站10kv電網的實際參數來建立數值計算模型,在考慮了電網接地電容電流變化、中性點電阻取值大小、接地點接地電阻值變化等多種影響因素的情況下,對中性點經消弧線圈接地和經小電阻接地方式下電網的過電壓水平和接地點短路電流大小進行了數值計算,其計算結果與電科院所作現場試驗進行了比較。
  4. Line - to - neutral voltage in a 3 - phase, 4 - wire, y - connected generator, line - to - neutral voltage is the voltage between a phase and the common neutral where the three phases are tied together

    相電壓在三相四線星形連接的發電機中,相電壓是指三相連接點與每相之間的電壓。
  5. Further, the methods are proposed to compare and summarize for choosing fault line and detecting distance in neutral ungrounded system. subsequently, the characteristics of zero sequence current and transient courses are introduced and analyzed

    接著對小電流接地系統單相接地故障時零序電流的暫態過程及特點做了介紹和分析。
  6. Since that the choosing line hardware for the neutral ungrounded system has just passed part of the dynamic simulative test, matlab software was chosen to do a lot of simulative tests on single phase - to - grounding fault. and the simulative sampling ratio is almost the same as the hardware ' s. because there is a low wave filter in the hardware, i choose the db15 wave - let to carry out the multidimensional decomposition on the sample by the method of one dimension discrete wavelet in order to obtain low frequency signal including the high frequency transient information on single phase - to - grounding fault

    鑒于實驗室已有的小電流接地系統選線硬體的研製只通過了實驗室里的動模試驗,故選用matlab軟體對小電流接地系統進行大量的單相接地故障模擬試驗,模擬的采樣率和硬體基本一致,由於硬體中帶有低通濾波器,故在進行采樣數據的morlet小波分析時先採用db15小波對采樣進行一維離散小波的多尺度分解,使得分解得到的低頻信號剛好包括了小電流接地系統單相接地故障時的暫態高頻信息,然後對這一信息再繼續進行小波演算法分析,分析結論表明利用變換后的實部、虛部和模值能夠較準確的實現單相接地故障時的故障選線和暫態高頻分量的提取。
  7. The single phase - to - grounding fault frequently occurs in neutral ungrounded system. the fault line must be found to avoid a phase - to - phase fault. in this paper, firstly, the condition on single phase - to - grounding fault occurring in neutral ungrounded system are discussed and then the main troubles in choosing fault line are pointed out

    本文首先分析了小電流接地系統發生單相接地故障時的情況,指出選線所遇到的主要困難,進而對小電流接地系統單相接地故障的選線及測距的方法做了比較和綜述。
  8. This paper analyses the transient character of line fault when the neutral point connects to ground in different ways. from the angle of signal processing, the wavelet packet analysis theory is introduced to selecting fault, in which the fault character is not the steady signal but the transient signal

    本文在中性點不同接地方式下,研究和分析了線路故障特徵量的暫態特點,主要從信號處理的角度,提出將小波包分析理論運用到故障選線。
  9. This paper analyses the steady and transient character of line fault when the neutral point connects to ground in different ways. from the angle of signal processing, the wavelet analysis theory and the artificial neural networks are introduced to fault location, in which the fault character is not the steady signal but the transient signal

    本文在中性點不同接地方式下,研究和分析了線路零序故障特徵量的穩態和暫態特點,主要從信號處理的角度,提出將小波分析理論和人工神經網路原理運用到故障定位,將基於穩態信號的定位原理轉移到基於故障特徵量暫態信號的定位原理。
  10. The generators are of three - phase four - wire type, making use of star connection with neutral point. the rated line voltage is 400v. phase voltage 230v. frequency 50hz, power factor 0. 8 ( lag ). it can provide 60hz and the other voltage ' s generator according to necessary

    本發電機為三相四線制,採用帶有中性點的星接法,額定電壓為400伏,相電壓為230伏,頻率50赫,功率因素0 . 8 (滯后)根據用戶需要,也可提供60赫及其它電壓值的發電機。
分享友人