open fault 中文意思是什麼

open fault 解釋
開口斷層
  • open : adj 1 開著的,開放的;可進入的,可分享的 (to); 無蓋的,敞口的;敞開的;展開的;開的;開闊的,開...
  • fault : n 1 過失,過錯;罪過,責任。2 缺點,缺陷,瑕疵。3 (獵狗的)失去嗅跡。4 【電學】故障,誤差;漏電...
  1. There is great change of negative current component when it happens the line - open fault. it is marked as the occurrence of the fault. and it can be concluded the phase characteristic of negative current in the line. in the transient course, there are plenty of harmonics in the fault line. through the transient analysis, it is drawed that the amplitude of each harmonic in fault phase is greater than other phases. harmonic current in fault line is far greater than other normal lines

    發生斷線故障以後,線路中會出現負序電流的突變,可以作為故障啟動判斷的標志,並且通過分析得出了故障時負序基波電流的相位特點。在故障暫態過程中,故障電流中含有大量豐富的諧波成分,各次諧波在故障期間有突變,並且衰減很快。
  2. Based on these research, we recovered the evolution history of overthrust faults vertical sealing ability and considered that there always have fracture activity ever since jidike formation deposition period. but this kind of activity is not always continuous. during moving period, fault is open

    在此基礎上對逆掩斷層垂向封閉性演化史進行了恢復,認為斷裂自吉迪克組沉積時期以來均有活動,但這種活動是間歇性的,活動時期斷層開啟,靜止時期斷層多是封閉的。
  3. We established geological and mathematic model for the relief of overthrust fault and earned out simulation computation after selecting factors. the result is that pressure can be released when fault is open. but ft will take a long time for the formation pressure to be relieved to normal formation pressure

    建立了逆掩斷層泄壓的地質模型和數學模型,選取參數后進行了模擬計算,結果表明逆掩斷層活動開啟釋放壓力,但要將地層壓力釋放到正常地層壓力需要時間較長,在斷裂活動時期不足以將圈閉中超壓釋放掉,這是庫車坳陷超壓能夠保存的另一主要原因。
  4. Through analyzing the two cases of protection malfunction due to incorrect connection of open - delta connection of busbar voltage transformer, the importance of correct connection of open - delta connection when earthing fault occurring in a power system was explained

    摘要通過分析兩起母線電壓互感器開口三角形接線錯誤引起的保護不正確動作,從而說明在系統發生接地故障時電壓互感器開口三角形接線正確的重要性。
  5. Analyzing the propagation behaviors for open and close crack, the author gain that normal fault is more dangerous to earthquake than reverse fault and glide fault. 3. appling fracture mechanics to discuss reservoir - induce earthquake mechanism, the author observes the characteristic of surface crack and gains the stress intensity factor induced by the pressure of rock, water and osmosis

    針對庫區斷層為表面裂紋這一特點,研究水庫地震的斷裂特點,得出地應力作用下的應力強度因子、庫水作用下的應力強度因子和滲壓作用下的應力強度因子以及它們的應力強度因子之合,並且合理的解釋了構造型水庫地震的誘發機理。
  6. Open networked manufacturing mode, networked real - time monitoring, nc equipment e - service system and framework and function of networked remote fault diagnosis as well as networked application in metalforming machinery have been described

    摘要闡述了開放式網路化製造模式、網路化實時監控、數控設備e -服務系統和網路化遠程故障診斷的構建與功能,以及鍛壓機械的網路化應用。
  7. A novel measurement and control system ( mcs ) used in hv flameproof switchgear has been established based on the 80c196kb single - chip microprocessor, by which electrical faults such as short circuit, over - load, over - voltage, open circuit, earth leakage and so on can be automatically distinguished and processed, and with the exception of this, the insulation degree of the double screen cables is monitored on - line. the operating condition and fault parameters can be displayed in turn with liquid crystal display

    該系統能自動判斷短路、過載、過壓、欠壓、漏電等故障,並對高壓電纜的絕緣水平進行實時監測,大屏幕液晶顯示器實現了電太原理工大學碩士學位論文網參數的輪流顯示,通過撥碼盤輸入系統各項整定參數,真正實現了保護系統數字化。
  8. In addition, the electromagnetic transients of normal operating - current state, primary side large current fault state and primary side open - circuit fault state are simulated

    對該電流互感器正常工作電流狀態、一次側大電流故障狀態及一次側開路故障狀態的電磁暫態過程進行了模擬。
  9. If wisdom is slow to open, could it be the fault of the " readers " - people who read extensively yet do not understand, always debating and arguing for the sole purpose of creating more conflict in the world. this is perhaps the message of the painting " argument ", which presents two enormous books opposing one another with the title " l " on their covers

    閱多而不解,又講出很多道理,只能給世界增加更多的沖突,這就是爭辯這幅畫里所體現出來的訊息,二大本書相對而立,封面上都寫著第一,畫的襯底是一張歪斜的深紫色的桌子,象徵著人類社會。
  10. One is hard fault, which means the stuck - open fault and the bridge fault ; another is soft fault, which refers to the component parameters going beyond the preassumed perfomance range. usually, these faults do not lead to a total failure of equipments

    一類稱之為硬故障,指元件的開路和短路失效故障,另一類稱之為軟故障,指元件的參數超出預定的容差范圍,一般它們均未使設備完全失效。
  11. Based on the model of the interconnect failure, taking the existence of defect into account, the influence of the open soft fault on the interconnect reliability is deeply studied, and a new lifetime model of interconnect is presented

    本文從互連線失效的電遷移模型出發,考慮到缺陷存在時,由局域缺陷導致的開路軟故障對互連線可靠性的作用,給出了缺陷統計分佈情況下新的互連線壽命模型。
  12. The minimum requirement for sensitivity shall be such that a succession of not less than 20 breakdowns of the spark gap shall cause the fault indicator to register neither more nor less than one cunt per breakdown when the spark gap is open and is of the length shown above, with the current limiting impedance in series with the gap

    在最底靈敏度測試的時候,應先接入上述要求的人工擊穿裝置,啟動人工擊穿裝置,使金屬板與金屬針間的火花間隙被連續擊穿20次,要求火花試驗機的擊穿計數器應記錄20次,對每次擊穿都應準確無誤地計數,不應多計也不應少計。
  13. The minimum requirement for sensitivity shall be such that a succession of not less than 20 breakdowns of the spark gap shall cause the fault indicator to register neither more nor less than one count per breakdown when the spark gap is open and of the length shown above, with the current limiting impedance in series with the gap

    在最底靈敏度測試的時候,應先接入上述要求的人工擊穿裝置, ,啟動人工擊穿裝置,使金屬板與金屬針間的火花間隙被連續擊穿20次,要求火花試驗機的擊穿計數器應記錄20次,對每次擊穿都應準確無誤地計數,不應多計也不應少計。
  14. For the convenience of test, varied circuit chip defects caused by the production process are abstracted as all kinds of models. at present the commonly used fault models mainly consist of stuck - at fault, stuck - open fault, bridge fault, store fault, delay fault, etc. testing methods based on voltage testing mainly aim at stuck - at fault model and have also obtained satisfactory result in research for many years. bridge fault is tested easily by quiescent power supply current ( iddq ) testing method. in regard to stuck - open fault that is difficult to testd by quiescent power supply current ( iddq ) and voltage testing, it can is tested by the dynamic current ( iddt ) testing

    為了便於測試,我們將生產過程中集成電路出現的多種多樣的缺陷抽象為各種模型。目前常用的故障模型主要有:固定故障,開路故障,橋接故障,存儲故障,時滯故障等。電壓測試主要針對固定型故障模型,多年的研究也取得了令人滿意的結果; cmos電路中的橋接故障則宜用穩態電流測試方法( iddq )測試;對于電壓和穩態電流難以測試的開路故障,可以使用瞬態電流測試( iddt )的方法進行測試。
  15. But, the alarm signals from scada have disadvantages as follows : ( 1 ) the open - air feeder terminal units ( ftu ) are interfered by strong electromagnetic and thunder. besides, the failure of relays and the fault of ftu can also lead to that fault information is interfered and aberrant. ( 2 ) in the process of transmission and commutation, the error in the communication equipment may result in the signals err or lose

    然而,現有的scada系統在配電網發生故障時提供給調度員的警報信息有如下局限性: ( 1 )面向現場的戶外饋線終端ftu運行環境惡劣,承受強的電磁、雷電干擾,並且由於繼電器節點故障、 ftu元器件損壞等因素的存在,使得配電網信息受干擾、畸變的可能性較高; ( 2 )在信號傳輸及變換過程中,通訊裝置的故障等原因,也可能導致信號出錯甚至丟失; ( 3 )保護裝置和斷路器本身也有可能誤動或拒動。
  16. It is the last day of 2006, it is the date that i open the blog of my own, it is the date i quit the qqgroup of wg. ( of curse, it is not their fault, for my fear, fear that my ignorance would cause something undesirable. ) in this blog, i may laugh, i may pretend to be thoughtful, and may cry after drinking

    今天是2006年的最後一天,卻是我個人博客的開張之時,也是今天我退出了烽火的qq群, (當然不是別人不好,而是自己多少覺得有點畏懼,畏懼的不是別人,而是畏懼自己的自以為是會帶給別人傷害)在這里似乎讓自己有了個可以宣洩情緒的角落,可以笑,可以故作深沉狀,也可以在酒後亢奮的那一瞬間痛哭流涕。
  17. In light of the system fault happened in shaoguan power plant, the electromagnetic process during the open - phase running of gate - out switch of generator - transformer unit is analyzed in detail with the measures to handle the failure included

    結合韶關發電廠曾發生的系統故障,詳細分析了發變組出口開關非全相運行時的電磁過程,提出了限制故障擴大的處理方法和故障發生時的安全處理措施。
  18. In the terms of the seriousness of consequences of a fault, short circuits are of far greater concern than open circuits, although some open circuits may present a potential hazard to personnel

    在一個錯誤的結果的嚴重性條款,雖然一些開路可以提出潛在的對人員的危害,但是與斷路相比短路具有巨大得多的關心。
  19. It include two children systems : the children system of stability analyses and the children system of control design. it can not only analysis the stability of slope and design the control design, but also have the capacity of fault - tolerant technique. it provide a quick and convenience measure for the west open development

    該軟體系統包括穩定性分析子系統和治理設計子系統兩大部分,既可以完成邊坡(滑坡)的穩定性分析和治理設計,同時軟體系統又具有較好的容錯性能,為西部大開發邊坡(滑坡)的治理設計提供了一套快速方便的有用工具。
  20. The stuck - open fault is simulated concurrently using iddt testing with the test pattern pairs generated above. through detaching a pattern pair into two independent patterns, the stuck - at fault are simulated concurrently. simulation results show better fault coverage. the

    最後,針對iddt測試的可行性,我們通過利用pspice軟體對s208電路中的一些故障做了模擬,這些故障包括開路故障和延時故障。
分享友人