original leakage 中文意思是什麼

original leakage 解釋
原有漏損
  • original : adj 1 原始的,固有的,本來的;最初的,初期的。2 原物的,原本的,原文的,原圖的。3 獨創的,創造性...
  • leakage : n. 1. 漏,漏出。2. 泄露。3. 漏出物,漏出量。4. 【商業】漏損率;漏損量。
  1. In this paper, according to the properties of secondary gas pools and the inclusion data, the secondary gas pools are though to be formed due to the leakage of the original gas pools penetratin through the regional caprock when the overpressures within lower overpressured strata release

    結合包里體測試計算,認為期形成原因主要是由於下部超壓地層進行超壓釋放,從而在區域性盈層內部形成一系列泄壓道,原生氣藏泄漏而形成的。
  2. The chemical grouting technique is widely applied in many kinds of engineerings, such as hydropower, tunnel, subway, mineral mountain, coal, transportation. . etc. the technique has characteristics of fleetness, economy, special and dependable etc. and develop its original effect well in civil engineering of waterproofing process, treatment to leakage, structural reinforcement

    化學灌漿技術在水電、隧道、地鐵、礦山、煤炭、交通等各個領域有很廣泛的應用。具有快速、經濟、獨特、可靠等特點,在土木工程的防滲、堵漏、補強、加固中充分發揮其獨到的效用。
  3. Ptfe is one of the most corrosion - resistant materials in the world. however it has defects such as the hot expansion and cold contraction rate is10 times larger than that of steel and the original cold fluidity ( creeping ) etc. therefore, as temperature increases, ptfe extends so excessively that it would collapse and then block the flow of media ; as temperature decreases, ptfe contracts so excessively that it would be ripped and then cause leakage

    Ptfe是當今最耐腐蝕的材料之一,可它被製造成襯里的時候,會存在熱脹冷縮比鋼鐵十多倍及固有的冷流性等缺陷,致使ptfe襯里管道、設備,在使用過程中,溫度高時, ptfe襯里層會伸長過多而內癟,阻塞了介質流通;溫度低時, ptfe層會收縮過大被拉裂而泄漏。
  4. Perforation of heat exchange tube, cracks on the jointing connection of heat exchange tube and tube bundle hoard result in the leakage of the tube bundle in sulfur condenser were analyzed, proposed precautions and countermeasures were derived from a combination of the plant operation conditions and equipment conditions, the original equipment with satisfactory outcome were revamped

    摘要分析了硫冷凝器換熱管穿孔及換熱管與管板連接焊接接頭出現裂紋導致管束泄漏的原因,結合實際工況提出了預防和處理措施,並對原設備進行了改造,效果良好。
  5. Add copper tape to the original transformer. they can reduce the ei type transformer leakage magnet

    原廠的ei變壓器為它加上隔磁環,以減少漏磁。
  6. It is proved that the improved structure has overcome original weakness of structure leakage uneven, raised the qualification rate of products, improved the technology of motor components, decreased the manufacturing cost, and will be more suitable for repetitive manufacture

    試驗證明改進后的結構克服了原結構內漏不均勻的弱點,提高了成品的合格率,改善了馬達零件的工藝性,降低了加工成本,更利於批量生產。
分享友人