phase measuring system 中文意思是什麼

phase measuring system 解釋
相位測量系統
  • phase : n 1 形勢,局面,狀態;階級。2 方面,側面。3 【天文學】(月等的)變相,盈虧;【物、天】相,周相,...
  • measuring : n. ,adj. 測量(的),測量用(的)。 remote measuring 遙測。
  • system : n 1 體系,系統;分類法;組織;設備,裝置。2 方式;方法;作業方法。3 制度;主義。4 次序,規律。5 ...
  1. It is necessary to control the mechanical stimuli precisely in the studies of cardiac mechano - electrical feedback ( mef ). in the present study a ventricular pressure - clamping system has been developed, which can be applied to isolated - perfused rabbit hearts. controlled by a computer, this system not only can make the left ventricle follow a command defining the same pressure wave as that during a beating cycle under physiological condition, but also deliver mechanical stimuli with a proper waveform to the ventricle at a particular time phase. this system integrates multiple functions, including perfusing, pacing, recording of electrocardiogram and monophasic action potentials, and clamping and measuring of ventricular pressures in isolated - perfused hearts. thus, it is a distinct system for investigating the phenomena and mechanisms of cardiac mef at organ level

    在心臟機械電反饋的研究中準確控制機械刺激是非常重要的.本研究室構建了一套適用於離體家兔心臟的心室壓力鉗系統.該系統通過計算機控制壓力鉗,不僅能模擬正常生理條件下左心室的壓力波形,還能在心室活動周期的特定時相、以適當波形對心室施加機械刺激.該系統集心臟灌流與起搏、表面心電圖記錄、單相動作電位記錄、心室壓力鉗制與測定等多種功能於一體,特別適用於器官水平上觀察機械電反饋現象並探討其機制
  2. Abstract : it is necessary to control the mechanical stimuli precisely in the studies of cardiac mechano - electrical feedback ( mef ). in the present study a ventricular pressure - clamping system has been developed, which can be applied to isolated - perfused rabbit hearts. controlled by a computer, this system not only can make the left ventricle follow a command defining the same pressure wave as that during a beating cycle under physiological condition, but also deliver mechanical stimuli with a proper waveform to the ventricle at a particular time phase. this system integrates multiple functions, including perfusing, pacing, recording of electrocardiogram and monophasic action potentials, and clamping and measuring of ventricular pressures in isolated - perfused hearts. thus, it is a distinct system for investigating the phenomena and mechanisms of cardiac mef at organ level

    文摘:在心臟機械電反饋的研究中準確控制機械刺激是非常重要的.本研究室構建了一套適用於離體家兔心臟的心室壓力鉗系統.該系統通過計算機控制壓力鉗,不僅能模擬正常生理條件下左心室的壓力波形,還能在心室活動周期的特定時相、以適當波形對心室施加機械刺激.該系統集心臟灌流與起搏、表面心電圖記錄、單相動作電位記錄、心室壓力鉗制與測定等多種功能於一體,特別適用於器官水平上觀察機械電反饋現象並探討其機制
  3. The short - baseline interferometer ’ s angle measurement accuracy is influenced by phase difference measuring accuracy, the base length measuring accuracy, the system operating wavelength ( frequency ) and so on, the article analyzes the existing theory, and emphatically analyzes the influence of base length measuring accuracy to the precision of angle measurement

    短基線干涉儀測角精度受相位差測量精度、基線長度測量精度、系統工作波長(頻率)測量精度等因素的影響,文中,在對原有理論進行分析的基礎上著重分析了基線長度測量精度對系統角度測量精度的影響。
  4. Therefore, the three fundamentals required to obtain high precise measurements are : 1 ) frequency stability and frequency difference stability of the double - frequency laser source as well as the stable equivalent length of bore ; 2 ) the measuring beam and the reference beam are placed very co - axially ; 3 ) capability of recording the sub - division of the period of phase change and a reversible counter system

    因而干涉儀系統達到高精度的基礎是:頻率及頻差穩定的雙頻激光源、穩定的等效腔長;測量光與參考光合光後有很高同軸度的光路結構;能可靠記錄相位差變化周期數的細分及可逆計數系統三部分。
  5. To the single pulse angle measuring, phase comparison and phase sum - difference angle measuring method are discussed and compared. sum - difference channel modeling and simulation are made. based on system research and signal processing discussed above, some basically jamming methods are discussed and simulated

    對于單脈沖測角方法,研究了相位比較法和相位和差單脈沖測角方法,對兩種方法進行了比較並給出了和差通道方向圖的模擬。
  6. This paper describes mainly system functions, measuring methods, circuit design, software program and errors analysis of a new type of measuring instrument. this instrument can measure and monitor electric parameters in single - phase circuits, three - phase ( three - wire or four - wire ) circuits. this system can be applied to electric devices and power plants, transformer substations with harmonic pollution. it can measure current, voltage, power, energy, frequence, power factor etc. it also can detect load quality, phase sequence, alarm, display and print results, as well as detect and dispose negative power

    該儀器適用於含有諧波污染情況下的機電設備現場、發電廠、供電局、企業變電所現場,可用來測量電流、電壓、有功功率、無功功率、視在功率、有功電能、無功電能、視在電能以及頻率和功率因數等電參數,並具有負載性質(感性、容性)判別,正、逆相序判別指示功能;超限報警功能;列印記錄功能和負功檢測及處理功能。
  7. At last, the testing experiments are done to check out the testing system. the result of the experiments indicates that the measuring accuracy grade is b to the gjb3370 - 98 standard. and the non - repeatability errors of the amplitude wide and the phase wide are both less than 10 %

    分析結果表明:測試系統達到gjb3370 - 98的測量精度b級要求;動態性能測試中幅頻寬和相頻寬的測量不重復性誤差小於10 % ,滿足測試系統提出的要求。
  8. 3. design and develop the device of motorcycle engine valve phase measuring system

    3 、摩托車發動機氣門相位測量裝置的設計開發。
  9. 2. analyze and compute the theory of motorcycle engine valve phase and compression ratio measuring system

    2 、對氣門相位、壓縮比測量的理論分析和方法計算。
  10. This paper presents the establish process of motorcycle valve phase and compression ratio measuring system during the development of motorcycle engine for the jia ling industry group

    本文介紹了嘉陵工業集團摩托車發動機開發中,氣門相位和壓縮比測量系統的建立過程。
  11. This thesis, with the distributed space - borne insar height measuring system as its background technology, is mainly about the systematic research the phase unwrapping, a key step in data processing of insar, especially the method of it on multi - baseline condition

    本文以分散式星載insar測高系統為背景,系統地研究insar數據處理中的相位解纏這一關鍵步驟,分析在多基線情況下的相位解纏方法。
  12. 2. firstly this paper introduce the whole machine balancing principle and method for dual - rotor systems with little rotating speed difference firstly, then discuss key points such as picking up base signal, picking up " pai " signal, measuring rotor speed, capturing the value of wave crest and through, calculating the phase values of unbalanced weight, processing odd phases and finding each rotor ' s amplitude. on the foundation of above theories, using signal process technique and chip microprocessors technique, we developed a portable intellectual instrument, the first domestic device. which can balance dual - rotor system with little rotating speed difference quickly and accurately

    本文從不解拍整機動平衡原理出發,在詳細討論基準信號、拍振信號的提取;轉速的測量;拍峰、拍谷的捕捉:不平衡相位的求法、特殊相位角的處理;內、外轉子幅值的確定等關鍵問題的基礎上,應用信號處理技術和單片機技術研製成功國內第一臺性能穩定、操作簡單、成本低廉且平衡速度快,平衡精度高的便攜式微速差雙轉子現場整機智能動平衡儀。
  13. Angle measuring precision phase sum / difference mono - pulse radar receiver is not only related to accurate strike to target, but also the base of successful penetration of interceptor missile for tbm anti - guidance system using two point sources of correlation, which is one of radar angle fraud technologies. thus, research on technical criteria influencing angle measuring precision of receiver is meaningful

    相位和差單脈沖雷達接收機的測角精度,不僅關繫到是否能精確地打擊目標,而且是tbm反制導系統利用相干兩點源雷達角欺騙技術,成功突防攔截導彈的基礎,所以對影響測角精度的接收機各項技術指標進行研究具有重要意義。
  14. The signal generator of sweep frequency is based on dds device ad9954, the signal measuring circuit is based on gain and phase detector ad8302, the real - time control and deal circuit is based on tms320vc5409, and the periphery interface circuit is based on at89s52. the system can generate sweep frequency signal with the frequency range from 100khz to 150mhz, and with the power range from - 45dbm to + 18dbm. it can measure the gain and phase of the network, display the measure data by liquid crystal displayed and print it by the printer

    該測試儀以dds晶元ad9954為核心構成掃頻信號源電路,以增益相位檢測器ad8302為核心構成檢測電路,以dsp晶元tms320vc5409為核心構成控制與運算電路,以及以at89s52為核心構成外圍介面電路。該測試儀能產生頻率范圍達100k ~ 100mhz ,功率范圍為- 45dbm ~ + 18dbm的掃頻信號,能對被測網路的頻率特性進行測量,並留有豐富的外圍介面,可以將測量數據繪圖通過lcd顯示或者由印表機列印輸出。
  15. In the paper, the design of the real - time test system for crystal parameters is presented. the signal generator of sweep frequency based on dds device ad9852, the signal measuring circuit based on gain and phase detector ad8302, and the real - time control and deal circuit based on tms320vc5416 and the design of high - speed printed digital & analog circuit board are discussed in details

    本文闡述了晶振實時測量系統的設計,介紹了以dds晶元ad9852為核心的掃頻信號源電路,以增益相位檢測器ad8302為核心的信號檢測電路,以dsp晶元tms320vc5416為核心的實時控制與運算電路,以及高速數模混合電路板的設計方法。
  16. A gis pd measuring system is established, including a conventional pd measurement system, uhf detecting system and a pd spectrum system. we can obtain pd signal characters by this system, such as uhf transient signal waveforms, uhf demodulating signal waveforms, the pd phase angle in ac, pd spectrum, and discharge quantities

    建立了gis局部放電測量系統,其中包括:常規局部放電測量系統、超高頻檢波測量系統和放電頻譜測量系統等,通過測量系統得到了gis內局部放電的超高頻暫態信號波形、檢波信號波形、工頻相位分佈、頻譜特徵以及常規視在放電量等特徵。
  17. The experience results indicated the reliability of this kind of thermostatic control system. the analysis and compare about modern dielectric loss measuring methods are presented on chapter 3, and the zero - crossing testing phase discrimination method is adapted as the measuring method of this measuring system. furthermore, applied high frequency pulse technique, channel self - correction technique, anti - harmonic technique are used to increase accuracy and reliability of measurement

    本文對現代介質損耗測量技術進行了分析與比較,採用過零鑒相比較法作為介質損耗測量方法,並結合外施高頻脈沖技術、通道自校正技術、抗諧波技術,設計了高精度介質損耗測量電路,有效提高了介質損耗測量的精度,減小了測量誤差。
  18. Is selected as the core processor and a high quality intelligent three - phase signal generator as well as a measuring system is included in this system

    該系統同時具備高質量智能化的三相諧波信號源與電參量測量功能。
  19. Phase difference measuring system based on virtual instrument

    基於虛擬儀器的相位差測量系統
  20. In chapter three, the importance of maintaining the equal optical path between measuring beam and reference beam in measuring horizontal and vertical vibration table are analyzed, and the factors having effect on contrast degree of interference fringe are introduced. for improving the accuracy of laser - vibration - measuring - system, the phase - modulation - multi - period - average method and the vibration isolated of system are analyzed

    第三章分析了光路設計中的等光程問題的重要性,以及影響干涉條紋對比度的相關因素;並從提高測量精度的角度分析了調相多周期平均法和系統的隔振。
分享友人