plasma analyzer 中文意思是什麼

plasma analyzer 解釋
等離子體分析儀
  • plasma : n. 1. 【生理】血漿;淋巴液。2. 【生物學】原生質。3. (做藥膏用的)膏漿。4. 【礦物】半透明的綠玉髓。5. 【物理學】等離子(體);等離子區。
  • analyzer : 測定器
  1. Objective to study acute myocardial ischemia, 70 rats had been used to produce myocardial ischemia. nitric oxide ( no ) had been measured in plasma. endothelin ( et ) and nitric oxide synthase ( nos ) had been studied with immuno - histochemical technique and an image analyzer, we wish to find sensitive methods for forensic identification of acute myocardial ischemia

    目的觀察大鼠急性心肌缺血模型早期正常區、交界區和缺血區心肌的病理改變, et和nos的表達和血漿no濃度的變化,試圖為急性心肌缺血猝死的法醫病理學鑒定提供客觀的形態學依據。
  2. Anqing diamond is well - equipped with alloy cast iron production line, ductile cast iron production line, stall band oil rings line and surface treatment line. our company has compound chrome plating, gas nit riding, salt nit riding, ceramics penetration, nana - meter technique, plasma spraying etc., advanced surface treatment and equipment. it is also equipped with light score analyzer, outline analyzer, pattern analyzer, metallograplry analyzer etc., and japanese germany examine instrument and technique

    帝邁德公司裝備精良,現有高合金鑄鐵球墨鑄鐵毛坯鑄造和加工生產線,鋼帶組合油環生產線,表面處理生產線,車柴環生產線,擁有復合鍍氣體氮化鹽浴氮化滲陶納米技術噴鉬等高新表面處理裝備及技術,配備光譜分析儀輪廓儀投影儀金相分析儀等先進的德日檢測儀器和檢測設備。
  3. ( 3 ) chapter v. plasma characteristics of rf ion source is investigated. a zero - dimensional numerical dynamic colisional radiative atomic and molecular ( cram ) model is suggested to simulate the microphysical process. all species " population number densities in plasma are calculated in non - thermodynamics equilibrium condition, and proton content in extracted ion current are measured with 60 ? magnetic analyzer

    ( 3 )提出了高頻離子源等離子體的零維cram模型( collisionalradiativeatomicandmolecularmodel ) ,計算了非平衡態( nte )下等離子體中分子、電子、離子、基態原子、激發態原子等粒子濃度,並在zf - 200kev中子發生器上,用60磁分析器實驗測定了引出束流的質子比。
  4. Plasma characteristics of a rf ion source are investigated by emission spectroscopy. the spatiotemporal spectral line intensities of the first three atomic lines in hydrogen bahner series ( = 656. 28, 486. 13, 434. 05nm ) of rf ion source plasma, are measured with calibrated optical multichannel analyzer ( oma ). some plasma parameters, including electron temperature, hydrogen atom density and hydrogen ion density, are calculated and analyzed using partial local thermodynamic equilibrium ( plte ) theory and abel transform

    實驗採用絕對定標后的光學多道分析系統( oma )測定了離子源等離子體不同時間和空間位置的氫原子巴耳末譜線系中前三條譜線( = 656 . 28 , 486 . 13 , 434 . 05nm )的強度,並採用plte的理論和abel變換方法,計算出了高頻離子源等離子體的電子溫度、氫原子濃度、氫離子濃度等參數在放電的不同階段和徑向分佈情況,並進行了簡要分析。
  5. An ion implanter without ion mass analyzer was applied to simulate the phi procedure to fabricate soi materials by implantation of water plasma ions. thin soi structure was successfully fabricated by the implanter using 50 ~ 90kev water plasma ion implantation with the dose ranging from 2 - 6. 5 + 017cm - 2 and, subsequently, the high temperature annealing

    我們使用無質量分析器的離子注入機,模擬等離子體離子注入過程,成功地在該注入機上用水等離子體離子注入制備出了界面陡峭、平整,表層硅單晶質量好,埋層厚度均勻的薄型soi材料。
分享友人