pseudo-static test 中文意思是什麼

pseudo-static test 解釋
偽靜力試驗
  • pseudo : adj. 〈口語〉假,偽,冒充的。
  • static : adj 1 靜止的,靜態的,靜力的。2 【物理學】天電的,靜電的。3 【無線電】靜態特性。4 固定的,不活潑...
  • test : n 1 檢驗,檢查;考查;測驗;考試;考驗。2 檢驗用品;試金石;【化學】試藥;(判斷的)標準。3 【化...
  1. The shear mechanism, failure mode, deformation capacity, bearing capacity and the reliability of the anchored angle steels of the wrapped steel concrete cast - in - site frame typical story exterior joints under the middle and high axial compression ratio ( n = 0. 3, 0. 5, 0. 6 ), the working performance, failure mode, and the shear capacity of top story joints under the crack moment, the hysteresis characteristic and the dissipation energy capacity of the test joints are all analysed based on the 1 / 4 model pseudo - static tests of five specimens of wrapped steel concrete cast - in - site frame exterior joints, which varied in axial compression ratio, distribution of the beam angle steels and the stirrup ratio

    基於上述分析,本次試驗通過五個外包鋼混凝土邊節點1 4比例模型的偽靜力試驗,以柱的軸壓比、梁角鋼布置形式、配箍率等為主要參數,分析外包鋼混凝土現澆框架一般層邊節點在中高軸壓比( n = 0 . 3 、 0 . 5 、 0 . 6 )條件下,節點的抗剪機理、破壞模式、變形能力、承載能力和角鋼錨固的可靠性;分析了頂層邊節點在張開彎矩作用下的工作性能、破壞模式和抗剪承載力;分析了試驗節點的滯回性能和耗能能力。
  2. To meet the demands for large space and flexible compartmentation of buildings, laminated vierendeel trusses are adopted in high - position transfer story structures. first the bearing characteristics are analyzed, in which reasonable stiffness ratio of the upper chord, middle chord, and lower chord is derived. then combined with an actual engineering model ( 1 8 similar ratio ), the static loading and pseudo - dynamic tests of two models for laminated vierendeel truss used in transfer story structures are conducted, in which one model adopts reinforced concrete, and the other adopts prestressed concrete and shape steel concrete. seismic behaviors are analyzed, including inter - story displacement, base shear - displacement skeleton curves, and equivalent viscosity - damping curves. a program is programmed to carry out the elasto - plastic dynamic analysis, and displacement time - history curves of the two models are derived. the test and analysis results show that the laminated vierendeel truss with prestressed concrete and shape steel concrete has excellent seismic behaviors. it can solve the disadvantages of laminated vierendeel trusses used in transfer story structures. finally, some design suggestions are put forward, which can be referenced by similar engineering

    為滿足建築物大空間和靈活隔斷要求,在高位轉換層結構中採用迭層空腹桁架結構.首先分析了其受力性能,得出了空腹桁架各構件合理的截面剛度以及布局形式.然後結合一實際工程,進行了兩榀迭層空腹桁架轉換結構模型( 1 : 8相似比)的豎向荷載下靜力試驗以及擬動力試驗.其中一榀為普通混凝土迭層空腹桁架,另一榀配置了預應力和鋼骨混凝土,對比分析了兩模型的層間位移比、骨架曲線以及等效粘質阻力系數等抗震性能的比較,並進行了彈塑性動力分析.試驗和分析結果表明,配置預應力和型鋼混凝土的迭層空腹桁架轉換結構具有良好的抗震性能,可以成功地解決迭層空腹桁架作為轉換層結構所產生的弊端問題,最後對這類轉換層結構提出了相應的設計建議
  3. The seismic behavior of longitudinal middling - high r. c shear wall with frame column is discussed through model experimentations and finite element methods in this paper, after taking frame - shear wall structure of a main factory building of the large capacity power plant as experimentative prototype. the major work as follow : in order to appliance pseudo static test, the longitudinal middling - high r. c shear wall with frame column in the large capacity power plant ' s main factory building has been simulated to a model structure with 1 / 15 reduced - scale. the contents of study are process of cracking, course of damage, skeleton curve, rigidity degradation, ductility characteristic etc. that the seismic behavior of this kind of middling - high r. c shear wall is excellent has been proved by chubby hysteretic curve and fine capacity of energy dissipation

    本文以某大型火電廠主廠房縱向框架一剪力墻結構為原型,通過模型試驗和有限元分析,研究了縱向帶邊框柱中高剪力墻結構的抗震性能問題,主要內容有:選用1 15縮尺比把某大型火電廠主廠房縱向帶邊框柱剪力墻原型結構模擬為一個模型結構,並進行了偽靜力試驗,研究了這類縱向帶邊框柱中高剪力墻結構的開裂與破壞過程、骨架曲線、剛度退化、延性性能等問題,試驗滯回曲線飽滿,消能能力強,說明此類中高剪力墻的抗震性能較好。
  4. The major contents are as following : through a test of 1 / 15 - scaled model, the shear wall of a longitudinal frame - shear wall structure main factory building of the large power plant is modeled as testing model structure, and is tested by pseudo static test. this paper mainly investigates the loading behavior, failure proceeding, strength, rigidity, deformation, ductility and energy dissipation capacity of the model structure

    主要內容如下:採用1 15縮尺比,把某大型火電廠主廠房縱向框架?剪力墻原型結構中的剪力墻模擬為試驗模型結構,並對其進行偽靜力加載試驗,研究了此類結構的受力特點、開裂與破壞過程、承載力、剛度、變形、延性及耗能性能等問題。
  5. Abstract : the general testing scheme of large - scale bridge model including static test, dynamic test and pseudo dynamic test are presented briefly in this paper

    文摘:主要概述大型橋梁模型試驗的總體試驗方案,包括靜力試驗、動力特性試驗和擬動力試驗;介紹了試驗的實施情況。
  6. Based on the pseudo - static experimental results of nine specimens 1 / 5 - scale specimens and failure characteristic in the structural test, the damage mechanism and the failure of abnormal joints under the shear force is analyzed. the paper discusses the possible affections of stirrup ratio, the changes of beam or column sections and initial eccentricity on carrying capacity of abnormal joints. according to experimental data, the formula for calculation of the shear - bearing capacity of abnormal joints is given

    針對該類框排架結構中通常存在異型節點的實際,在9 (其中邊節點4個、中節點5個)個1 5的偽靜力試件試驗研究及整體結構模型中該類節點破損特點的基礎上,提出了異型中節點和邊節點的破壞機理,針對異型中節點和邊節點的受力特點給出了該類異型節點的抗剪承載力計算公式和節點區的加強構造措施。
  7. Seismic design concept from a pseudo - static test of steel reinforced concrete frame - core wall structure model with transfer floor

    核心筒結構模型擬靜力試驗對抗震設計的啟示
  8. Structure will be a kind of ductile structure with advanced seismic behavior. based on the tests of 25 elements of hollow shear wall r. c. structure and 16 hollow shear wall, we had accomplished pseudo - dynamic tests which employed el - centro wave with different input peak acceleration and pseudo - static test of 1 / 2. 8 scale model 10 - story building

    在已完成了25個基本空心剪力墻試件和16個墻片的試驗基礎上,進行了空心剪力墻結構十層樓房1 2 . 8的模型擬動力、擬靜力試驗,擬動力實驗採用不同輸入峰值加速度的el - centro ( ns )波。
  9. Though the pseudo - static test of three prototype - modal sandwich wall with angled - steel column, seismic behavior are discussed. based on the concrete nonlinear analyzing theory, this paper constructed the finite element modal by ansys program and proved the modal by test result. designed & further improved methods are presented on the conclusion of tests and calculations

    本文通過對三個角鋼邊框復合剪力墻板的原型擬靜力試驗,研究了角鋼邊框復合剪力墻的抗震性能,同時在現有混凝土非線型分析理論的基礎上,採用ansys有限元分析程序建立了墻板的有限元模型,結合試驗數據對模型進行了驗證。
  10. The paper probed the applying of multi - ribbed slab with outer light frame structure ( mrsolfs ) to the upper structure of buildings with commodious space at the bottom and the feasibility of replacing lfswsums with frame - supported multi - ribbed composite slab structure ( fsmrcss ). firstly, the paper carried out test study base on the pseudo - static test under horizontal loads on four two - spanned model members of fsmrcss, including three 1 / 2 - scaled two - storeyed models and one 1 / 3 - scaled three - storeyed model. by the test study, the paper analyzed the test results, including analysis on mechanical property of the constructure under vertical loads, and failure mode, deformation capacity, aseismic performance under horizontal loads and constant vertical loads

    本文首先對三個兩跨兩層和一個兩跨三層的底部大空間框支密肋復合墻結構的1 2和1 3比例模型進行偽靜力試驗研究,通過對底部大空間框支密肋復合墻結構在豎向荷載及與水平低周反復荷載共同作用下的受力性能的試驗研究,探討了結構的變形性能、滯回耗能和破壞形態,並與框支砌體結構進行對比分析。
分享友人