  1. The way of taking one nth out of capacitor ' s the first harmonic capacitive reactance as its nth harmonic impedance is verified whit the data from tang7c. according to the approximately estimating method, the first harmonic impedance of 220kv system is calculated. on the basis of the models, this paper gives the harmonic equivalent circuit of substation and gives the b ( n ) function of the harmonic time n. when the capacitors has different combination, b ( n ) ' s value will also change, with the inputting local measurement data, the paper studies the series and parallel resonance at the substation, and deduces that the reason the capacitor ' s fuse of tang6c is frequently interrupted is that its capacitor current contains a large number of 5th harmonics, and that the reason the discharging pt of tang7c capacitor being exploded is also that the 7th and 9th harmonic currents are amplified

    據此,對該站進行了串聯諧振分析和並聯諧振分析,並結合測試數據和有關變電站的運行記錄,指出了導致該站電容器湯6c頻繁燒保險的主要原因是5次諧波電流含量偏高,引起湯7c放電pt爆炸也是因為7次和9次諧波電流被放大。針對這些導致湯陰變電站補償電容器故障的原因,提出了相應的諧波治理措施,包括針對湯6c電容器5次諧波電流含量偏高的原因,提出了停運湯6c電容器或者通過把湯sc電容器的部分容量併入湯6c電容器(湯sc其餘部分停運)以增加湯6c諧波承受能力的措施;針對# 2變低壓側7次和9次諧波電流被放大的現象,提出了在湯7c電容器上加裝一定百分比的串聯電抗器的措施。
  2. 3. we do short circuit analysis upon multiple magnetic circuit transformers by use of steady non - linear analysis and get the leakage reactance respectively between high voltage and high voltage 、 high voltage and low voltage 、 two high voltage and low voltage 、 low voltage and high voltage and low voltage and two high voltage. what ’ s more, we do finite element analysis upon the temperature field of transformers and according to its distribution we get the wind speed to forced air cooling

    3 、採用穩態非線性分析法對多磁路變壓器進行短路阻抗計算,利用能量法計算出變壓器高壓與高壓、高壓與低壓、兩高壓與低壓、低壓與高壓以及低壓與兩高壓之間的漏感;對變壓器的溫度場進行有限元分析,確定溫度場分佈情況。
  3. The post research and statistics indicate that measuring the short - circuit reactance of power transformer is an effective method to estimate transformer winding deformation

    實踐證明,通過測量變壓器繞組短路電抗來判斷變壓器繞組是否變形是一種有效的方法。
  4. The low voltage impulse method, frequency response analysis method and short - circuit reactance method, which can be used to measure and diagnose the deformation of power transformer winding, are introduced in the paper

    目前,監測變壓器繞組變形的方法主要有低壓脈沖分析法( lvi ) ,頻率響應分析法( fra )和阻抗分析法。這些方法都需使變壓器退出運行,在變壓器離線情況下對變壓器繞組變形進行測量的。
  5. These tubes have a thickness not exceeding 15mm because of skin effect. the connection between transformer and cables can include the closing of the transformer delta, and its layout wil aim at optimising and balanching the circuit reactance

    因集膚效應,管厚要求不超過15毫米.變壓器和電纜的連接可形成一個三角形的閉合形變壓器,這種設計旨在優化和分流電抗
  6. Then the operation principle of the device is introduced to the readers and the definition of the limiting rate of the fault current and the compensation degree of the series reactance is done. in this section, the author designs the snubber circuit and the gate drive circuit of the gto

    首先,在總結前人研究成果的基礎上,提出了pwm - fcl的拓撲結構,並對其工作原理進行了闡述,給出了限流度以及補償度的定義,並針對gto的特性,設計了其緩沖保護電路和門極驅動電路。
  7. The author introduces in detail the affection of adding magnetism, subtract magnetism of permanent magnet to reactance measurement, as well as the circuit and experiment condition under the influence of the cross saturation effect

    詳細介紹了電壓積分法中電抗參數受永磁體增磁、去磁效應影響以及受交叉飽和效應影響時的測量電路和試驗條件。