row of holes 中文意思是什麼

row of holes 解釋
炮孔排
  • row : n 1 (一)排,(一)行;一排(座位);行列,橫列。2 (兩旁或一旁有房屋的)路,街〈英國常用作某種...
  • of : OF =Old French 古法語。
  • holes : 安裝孔
  1. The thermal visualizations of jet impingement cooling with single or double row holes inside semi - enclosed channel are measured by using infrared camera and then the impingement cooling heat transfer coefficients are deduced. the effects of flow and geometry parameters on convective heat coefficients are obtained. the results show that : for a single row normal impingement, the impingement cooling effectiveness is enhanced with the increase of impinging reynolds number or the decrease of hole space to diameter ratio, and the best effectiveness is achieved under the jet - to - surface spacing equals to 2 ; when the jet is oblique to the confined wall, the cooling effectiveness is weaken especially under the jet - to - surface spacing ratio is greater than 2 ; for double rows normal impingement cooling, the cooling effectiveness of rear row jet is weaker than the front row under lower impinging reynolds number or bigger jet - to - surface spacing

    對于單排垂直射流,沖擊冷卻效果隨射流雷諾數的增加、孔間距與直徑比的減小而得到提高,沖擊間距比為2時換熱效果最好;沖擊孔中心線向通道封閉一側傾斜后,射流沖擊冷卻的范圍變窄,當沖擊間距比大於2時駐點區的對流換熱能力明顯降低;對于雙排沖擊射流,孔排間距與直徑比的增加使沖擊冷卻范圍變大,但在兩排孔之間區域的對流換熱系數有所下降;在較小的沖擊射流雷諾數和較大的沖擊間距比下,後排射流的沖擊換熱效果要遜於前排射流。
  2. The cooling effectiveness of effusion cooling in the regions with holes and downstream the last row of holes on hot side is much higher than that of conventionary film cooling with the same operation conditions

    在熱側面上的氣膜孔區及其下游區,緻密多孔壁的冷卻效果都非常好,比同等條件下常規氣膜冷卻的效果好得多。
  3. ( 2 ) on the leading edge, the film cooling effectiveness at the zone immediately downstream of the cooling holes is affected by blowing ratio and mainstream reynolds number, while the effects are not important in the downstream zone far from the cooling holes. ( 3 ) on the front half of pressure surface, the effectiveness increases with decreasing blowing ratio at the downstream near the cooling row and it is contrary at the downstream far from the cooling row. ( 4 ) on the rear pare of the pressure surface, the effectiveness decreases with increasing blowing ratio and does not vary so much downstream in the cases of higher blowing ratio

    研究結果表明葉片吸力面端壁附近區域壓力系數分佈呈現出較強的三維特性,動葉吸力面尤其明顯;氣膜孔流量系數隨吹風比的增加而增大,在高吹風比情況下,流量系數逐漸趨于常數;在不同型面區域,冷卻效率分佈有較大的差異,而且吹風比與主流雷諾數的影響程度也不盡相同;低吹風比下,孔出口下游附近可以得到較好的冷卻,中、高吹風比下,冷氣射流在加速流動主流的作用下返回壁面進行二次冷卻,孔下游較遠區域可以得到較好的冷氣覆蓋。
  4. Then the thermal visualizations of jet impingement cooling with single or double row holes inside semi - enclosed ribbed channel are measured by using infrared camera and the effects of flow and geometry parameters on convective heat coefficients are obtained. the results show that : the impingement cooling effectiveness of ribbed surface is affected greatly by the jet - to - surface spacing, and the best effectiveness is achieved under the jet - to - surface spacing equals to 1. the correlation formulas of impingement heat transfer characteristics to the parameters are finally concluded and in good agree with the experiment data

    最後,對單排、雙排沖擊孔試驗板在半封閉通道展開了流量系數的研究,在變化各種幾何因素及流動因素的情況下由實驗得出了沖擊孔流量系數值,討論並分析了各種因素對流量系數的影響程度,建立了沖擊孔流量系數的準則關系式,與實驗結果對比表明:該準則關系式與實驗實測數據吻合較好,精度較高,有較高的工程應用價值。