safety grounding 中文意思是什麼

safety grounding 解釋
安全接地
  • safety : n. 1. 安全;平安,穩安,保險。2. (槍等的)保險器,安全瓣;〈口語〉低座腳踏車[自行車] (=safety-bicycle)。3. 安全設備,保險裝置。4. 【棒球】安全打。
  • grounding : n. 1. (畫、刺繡等的)底子。2. 基礎訓練;初步。3. 【航海】擱淺。4. 【電學】接地,通地。
  1. In this paper, the application of centum cs1000 of yokogawa in the benzene chloride production is discussed. the system struct, software and hardware of the engineering workstation and human interface station, system configuration, safety property and grounding are also studied

    本文以實際工程為背景,論述了橫河的centumcs1000在氯化苯生產過程中的應用,對系統選型、工程師站和操作員站軟硬體配置、現場控制站配置、系統組態、安全性、接地等問題進行了一定的探討。
  2. Fzn25 and fzrn25 series has mutual - linkage grounding valve of grounding swith between static contact and moving electric torch, so it can make sure safety and convenient maintenance

    Fzrn25在靜頭與動導電筒之間有接地開關互為聯動的接地活門,既保證了安全又方便檢修。
  3. The grounding grid is vital to the safety of the substation

    接地網對保證變電站安全運行至關重要。
  4. The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance

    爭議點主要是在10kv電網接地故障的形式、消弧線圈接地的應用范圍、兩種運行方式供電可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以電纜為主的城區10kv電網中性點接地方式的選擇問題進行研究。論文首先對10kv電網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變電站10kv電網的實際參數來建立數值計算模型,在考慮了電網接地電容電流變化、中性點電阻取值大小、接地點接地電阻值變化等多種影響因素的情況下,對中性點經消弧線圈接地和經小電阻接地方式下電網的過電壓水平和接地點短路電流大小進行了數值計算,其計算結果與電科院所作現場試驗進行了比較。
  5. In the present grounding measurements in substations, the large electric current method is used to raise the ratio of signal to noise, but this method does not obviously decrease the measurement error. the test instruments are unwieldy, and it is easy to threaten personal safety

    在現有變電站接地網接地測量中,採用大電流測試法來減小測量誤差,其消除干擾的效果並不理想,且此方法測量設備笨重,還可能危及人身安全。
  6. The first part of the paper is designing the testing project for grounding resistance and insulation resistance in a new way. using 16bits ad converter with programmable control amplifier replaced the way which used changing resistance to change measure range. lt is not only improved testing precision and develop the system expediently, but also reduced the area of the circuit boardwith the new way. in order to make the electric implement safety testing system have upstanding expansibility, the software and hardware of the system adopted the modularization design. adopted mcu atmegal28 as a master mcu which control mmi, realtime clock and communication with slaver mcu. atemga8 as the slaver mcu to realize testing function. so it is easy to add or reduce the testing project. the testing implement system has been developed successfully, and the comments for the system is that it has high precision, high expansibility and easy maintain. but considering the electric implement system should have intelligence and humanity abi lity. so this paper bring forward a scheme of electric equipment safety testing embedded system with speech control. after introduce the basic theory of speech recognition, the paper expatiate the characters of this system. the system is a noise conditon, not special people, small glossary, insulation word system. with these characters design the speech recognition as fellow. utilizing cross zero ratio and short energy to ensure jumping - off point and end point ; adopting mfcc as the character parameters of speech recognition ; the character parameters than be recognized by dtw. in order to ensure the credibility of this project, first realized by matlab in computer

    在介紹了語音識別的基本原理后,闡述了本系統的特點:本系統是一個噪聲環境下非特定人、小詞匯量、孤立詞的語音識別系統。根據本系統的這些特點設計了如下語音識別方案:利用過零率和短時能量相結合的方式確定語音端點;採用mel頻率倒譜系數( mfcc )作為語音識別的特徵參數;得到的特徵參數最後通過動態時間規整( dtw )的模式識別方法進行識別。為了確保本系統實現方案的可靠性,首先通過計算機利用matlab軟體來模擬,在演算法模擬實現后又進一步增加環境的復雜性:加上較大的環境噪聲、突發性的噪聲等,再通過修改參數、修改參考模板、兩級識別等各種提高語音識別精度的方法來提廣東工業大學工學碩士學位論文高識別率。
  7. Guide for measurement of impedance and safety characteristics of large, extended or interconnected grounding systems

    大型,擴展或互連接地系統阻抗及安全特性測量指南
  8. It is important to ensure the safety of microcomputers and its operators by reducing the environmental resistor of grounding body, and thus it is required to adjust and choose the resistor decreasing environment according to different edatopes

    針對不同的土壤環境,進行必要的調整和選擇,降低接地體的環境電阻,保障微機及操作人員的安全,具有重要意義。
  9. Guide for safety in ac substation grounding

    交流變電站接地安全指南
  10. Ac substation grounding, safety in

    交流變電站接地安全性
  11. This course provides the background knowledge : safety of passengers, action for collision or grounding and search and rescue to support the tasks, duties and responsibilities in response to navigational emergencies

    此課程提供足以勝任應急措施工作與職責之旅客安全、碰撞或擱淺后之行動與搜索與救助知識。
  12. Universal ac power supply voltage ac100 240v without grounding safe - ss save safety terminals

    國際通用ac電源電壓ac100 240v無需接地採用安全型ss save safety端子。