secondary switching 中文意思是什麼

secondary switching 解釋
次級接續
  • secondary : adj 1 第二(位)的,第二次的;中級的 (opp primary)。2 副(的);從屬的;附屬的;輔助的;補充的...
  • switching : 變換
  1. By compared with the simulation results and the experiment results, we come to the conclusions that : ( 1 ) circuit with assistant network can widen soft - switching extent in lagging arm, reduces duty - cycle loss on the secondary, diminishes switching dissipation of inverter spot - welding power source. ( 2 ) the range of resonant capacitor, the important factor to soft - switching process, not only affects zero - voltage turn - off of power switches, but also affects the range of zero - voltage turn - on of power switches. so resonant capacitors must be considered according to many aspects ; ( 3 ) it easily fulfils soft - switching condition in lagging arm as leakage inductance of power transformer increases, but bigger leakage inductance of power transformer increases opening dissipation of transformer and decreases efficiency of soft - switching inverter power source

    通過模擬結果與軟開關點焊逆變器試驗結果的對比分析,得到了如下主要結論:採用輔助網路可以完全拓寬全橋軟開關逆變器的滯后橋臂軟開關范圍,減小了次級占空比丟失,降低了逆變電阻點焊電源的開關損耗;諧振電容是影響軟開關工作狀態的重要因素,其大小不僅影響開關管的零電壓關斷,同時也影響開關管的零電壓開通范圍,因此,諧振電容應該綜合考慮;功率變壓器漏感越大,越容易滿足滯后橋臂的軟開關條件,但是大的漏感也使變壓器的通態損耗增加,降低了軟開關逆變器的效率。
  2. Secondary air switching valve

    二次空氣轉換閥
  3. In this thesis, the tradition phase - shift full - bridge zvs dc / dc converter are analyzed, and then a new dc / dc full - bridge converter employing switches clamping in secondary side of transformer is proposed, and the converter employing saturable inductor clamping are studied, and zvs ( zero - voltage - switching ) can be easily achieve by experiment validate

    本文分析了一些傳統的移相全橋軟開關變換器,提出了開關管箝位dc dc全橋變換器拓撲方案,並對飽和電感器箝位dc dc全橋變換器進行了研究,並進行實驗驗證,從而解決了開關管的零電壓開關問題。
  4. It emphases the selection of secondary voltage of the step - down transformer, the control and protection of thyristor, the calculation of compensation capability and group capability, the technique of cross - zero switched on / off capacitors or reactor, the solution of avoiding possible resonance in switching on / off groups of capacitors or reactor and the measure of the best time to switch ( including the design of the computer survey and control system, instrument deliver system, delay operate and protect system ). although thyristor as a no - contact switch can avoid almost the problem of contact switch with contact, it can not solve the over - voltage, over - current and transient process itself as switching on / off capacitors or reactor. so we must develop a set of thyristor - switched control and protect system with great reliability so that it can realize of cross - zero switching on / off capacitors or reactor at any time

    晶閘管具有過零、動作快速的特點,本研究以晶閘管為電容器和電抗器的分組投切開關,重點研究了協調變壓器二次電壓的選擇、晶閘管觸發控制及保護、動態補償容量及分組容量的計算確定、過零投切電容器和電抗器技術的實現、以及分組投切電容器和電抗器可能發生諧振的處理計算方法,給出實現最佳補償投切選擇方法(測控系統、儀表變送系統、操作和保護系統的設計步驟) ,研製了一套高可靠性晶閘管觸發控制及保護系統,實現對無功的靜止可調補償。
  5. Having all files in place simplifies switching to the secondary server

    使所有文件保持位置不變可簡化切換到輔助服務器的過程。
  6. Representatives of the kowloon - canton railway corporation, parknshop, caf de coral holdings limited, the university of hong kong, hong kong subsidized secondary schools council, hong kong association of property management companies ltd. and various taxi and minibus associations also attended the ceremony to pledge their support for setting the air - conditioning room temperatures at 25. 5c and switching off idling engines

    九廣鐵路公司百佳超級市場大家樂集團有限公司香港大學香港津貼中學議會香港物業管理公司協會以及多個的士及小巴團體亦派出代表出席是次活動,表示對推行適當空調室溫25 . 5度或停車熄匙的支持。
分享友人