sensitivity response 中文意思是什麼

sensitivity response 解釋
靈敏度響應
  • sensitivity : n. 1. 敏感(性);感受性。2. (儀器等的)靈敏性。3. 【攝影】感光度。
  • response : n. 1. 回答,答復。2. 【宗教】應唱聖歌。3. (因刺激等引起的)感應,反應,反響;應驗;【物理學】響應;【無線電】靈敏度,感擾性;特性曲線。
  1. A novel protein immobilization approach for piezoelectric immunosensors based on the sam of derivative aa has been proposed, which is formed by coupling merca ptoprorionic acid ( mpa ) to alginic acid sodium salt via edc and nhs. ( 1 ) the tr antibody is immobilized via edc and nhs. comparing with the mpa sam method, this new approach shows greater frequency response and high sensitivity

    應用edc和nhs使褐藻酸鈉與胱胺偶合形成衍生褐藻酸鈉作新的自組裝材料,用於蛋白固定,應用這一新方法, ( 1 )實現了轉鐵蛋白抗體分子的固定,並對轉鐵蛋白參考血清進行了測定,該方法可在0 . 08 25 . 7 g / ml范圍內對轉鐵蛋白進行測定。
  2. Piezoelectric immunosensing technique incorporates the high sensitivity of piezoelectric quartz crystal microbalance and high specificity of antibody - antigen immunoreaction, presenting some outstanding advantages including desirable simplicity, rapid response, and so on, which make it showing an attractive future of potential applications in the biochemical diagnosis of clinical diseases

    壓電免疫傳感技術結合了壓電石英晶體高靈敏性和免疫反應的高特異性,具有測定過程簡便、快速等特點,在生物分析中具有廣闊的應用前景。
  3. 4 - vp - co - buma quaternized with octyl bromide were found to be humi - sensitive material with good linearity, high sensitivity, fast response, high stability at high humidities

    以溴代正辛烷季胺化4vp - co - nbuma為濕敏材料,制備濕敏元件,其具有響應線性度好、靈敏度高、響應快、高濕穩定性好等優點。
  4. Based on the analysis of the dynamic behavior of nanning bridge by means of spatial finite element models, the nonlinear dynamic time history method is used to conduct the sensitivity analysis of the parameters of viscous dampers ( damping constant c and damping exponent ? ) of the bridge and the laws of influence of the parameters on the seismic response thereof have been obtained

    摘要在來用空間有限元模型對南寧大橋動力特性分析的基礎上,採用非線性動力時程分析方法,對南寧大橋粘滯阻尼器參數(阻尼常數c 、阻尼指數? )進行敏感性分析,得出粘滯阻尼器參數對南寧大橋地震響應的影響規律。
  5. This sensor has higher sensitivity and excellent stability, in the detection of gas oxygen and dissolved oxygen, the response time were 5. 57s and 14. 625s

    實驗結果證明,測定膽固醇用的熒光式光纖生物傳感裝置具有較高的靈敏性和優良的穩定性,其測定氣體氧和溶解氧的響應時間分別為5 . 57s和14 . 125s 。
  6. Meba - co - si was found to be humi - sensitive material with good linearity, high in abstract sensitivity and fast response

    其具有響應線性度好、靈敏度高、響應快等優點。
  7. When the antigen ( brief named ag ) invaded into the organism, and the body can produce a kind of material ( high molecular weight protein, named antibody, brief named ab ) that can distinguish this antigen and evacuate it, the antigen and antibody take place the immuno - reaction. using their highly sensitivity to response mass change and specificity, it can be fabricated a piezoelectric immunnosensors

    當異種蛋白(稱為抗原, antigen ,簡稱ag )侵入生物體內時,體內能產生識別此類異物並將其排出的物質(大分子量蛋白質,稱抗體antibody ,簡稱ab ) ,抗原與抗體發生免疫反應,利用抗體(或抗原)對抗原(或抗體)的特異性識別功能和壓電晶體的高靈敏質量響應可製成壓電免疫傳感器。
  8. A new enzymatic electrode for glucose determination was developed by codepositing glucose oxidase into the polymer from electrochemical oxidation of dopamine ( da ) on a pt - modified 8b pencil lead electrode, followed by electrochemically depositing an outer poly ( o - aminophenol ) film, which exhibited very good performance, such as fast current response, high sensitivity, broad linear range, excellent stability and good anti - interferent ability for ascorbic acid and uric acid

    摘要市售8b鉛筆芯經鍍鉑處理后,將葡萄糖氧化酶共沉積到新型多巴胺電氧化聚合膜中,最外層再修飾聚鄰氨基酚薄膜,研製出新型葡萄糖氧化酶修飾電極用於葡萄糖檢測。
  9. New tracers and their analysis methods, new developments on the interpretation of tracer response and new concepts & methods contributed on tracer methodology. since 1980s, interwell radiotracer test has gained rapid development. the main reasons are radiotracers has the advancetages of high sensitivity, wide selectivity and no chemical contamination on the reservoir

    自上世紀八十年代以來,放射性井間示蹤測試在國際上得到了很大的發展,主要是因為放射性示蹤劑具有種類多、檢測靈敏度高、並且對油藏不產生化學污染等優點。
  10. The bleaching experiment of loess by iodine tungsten lamp and the equivalent dose ( de ) of loess estimated by sar from the earth ' s surface indicate that loess can be easily bleached by sunlight, and osl is suitable for the dating of loess. 2. equivalent dose estimated by sar, when each natural or regenerated dose osl measurement is corrected for changes in sensitivity using the osl response to a subsequent test dose and the recycling ratio is around 1, implies that sensitivity changes have been properly corrected

    用單片再生劑量法( sar )測定黃土樣品的d _ e值時,用固定的實驗劑量釋光信號校正後,再循環比( recyclingratio )都在1左右,說明對釋光靈敏度的變化起到了很好地校正作用;校正後, ogy再生劑量釋光信號與自然信號的比率都在5以下,信號的回復可以忽略不計。
  11. The dynamic equation for analyzing torsional vibration of the vehicle drivetrain is established based on analyzing the jointing process of frictional clutches, and the inherent frequency, the response of torsional vibration and the sensitivity of rigidity parameters to inherent frequency are studied

    摘要文章在分析車輛最常用的膜片彈簧摩擦離合器接合過程的基礎上,建立汽車傳動系的扭轉振動的力學分析方程;結合實際車型,分析了車輛的固有頻率、扭振響應、剛度參數對固有頻率的靈敏度。
  12. Two random response models in problematic investigation of quantitative character sensitivity

    數量特徵敏感性問題調查的兩個隨機化回答模型
  13. The results show the model has greatest sensitivity to the soil texture variation, but has little response to soil color

    敏感試驗結果表明,模式對土壤顏色的敏感性不強,對土壤質地比較敏感。
  14. Dna electrochemical biosensors have received much attention due to the high sensitivity, specific, rapid response, easy handling, compatibility with miniaturization technology, and low cost

    Dna電化學生物傳感器具有dna雜交反應高度的特異性,又具有電化學傳感器靈敏度高、響應快、操作簡便、微型化、價格低廉等顯著優點,成為近年國內外研究熱點。
  15. Frequency response, quantization noise, reconstruction error and its sensitivity to mismatch among adcs are studied at length in prqmf banks adc system, and the theoretic results include : ( 1 ) the distortion / aliasing functions of hybrid filter banks adc system is similar with that of switch capacitor filter banks adc system ; ( 2 ) for wide or narrow band input signal, the effective resolution of the two adc systems is 0. 51og2m bits higher than their adc ; ( 3 ) reconstruction error ' s sensitivity to mismatch among adcs of the two adc systems is reduced effectively than time interleaved adc system

    2對prqmf濾波器組adc系統的頻響、量化噪聲特性、重建誤差特性以及重建誤差對adc間的失配敏感性進行了理論分析研究,所得到的理論結果為: ( 1 )混合濾波器組adc系統與開關電容濾波器組adc系統的失真/混迭函數一致; ( 2 )無論輸入寬帶還是窄帶信號,這兩種adc系統的有效解析度均比其adc提高了0 . 5log _ 2m比特; ( 3 )這兩種adc系統的重建誤差對其adc間的失配敏感性均明顯低於時間交織adc系統。
  16. After measuring dark current, photocurrent and response to x pulse of gaas detector before and after 1. 7 mev electronic radiation, the response tune, fall time of trailing edge, full width of half maximum ( fwhm ), sensitivity, carrier life, mobility are researched and contrasted. the result shows that the response speed of detector, time resolution ratio and nonlinear of back edge of output signal have been improved greatly after electronic radiation. though sensitivity of the detector reduces, its measuring range can be widened

    為了使探測器的性能得到進一步的提高,我們對其進行了電子輻照改性,並測量了本徵砷化鎵探測器和經過1 . 7mev電子輻照的探測器的暗電流、光電流及對x射線的脈沖響應,並對其響應時間,后沿下降時間,半高寬( fwhm ) ,載流子壽命,靈敏度進行對比,研究,結果顯示經電子輻照后的探測器的性能得到了改善,使響應速度,分辯率進一步提高,並消除了探測器輸出信號后沿的非線性,雖靈敏度有所降低,反而使其測量范圍得以拓寬。
  17. Studies on piezoelectric immunosensors based on plasma - polymerized film. ( abstract ) the piezoelectric immunosensors posses high sensitivity of response to mass and high specificity of bio - chemical reaction as well

    壓電免疫傳感器具有壓電質量響應的高靈敏性和生化反應的高特異性,在生物傳感器的研究中日益受到重視。
  18. Piezoelectric sensing technique has been applied to many fields, including analytical chemistry, life science, environmental monitoring and surface sciences because of it ' s small size, high sensitivity, simplicity, low power consumption and broad sensing spectrum. piezoelectric immunosensors possess high selectivity provided by antibodies or antigens and sensitivity response directly to the mass change of proteins. immobilization technologies of biomolecules are of paramount importance in order to preserve their biological activity

    壓電免疫傳感技術利用壓電晶體與抗原抗體特異性免疫反應結合的特徵,通常在壓電石英晶體表面先固定抗原(抗體) ,響應溶液中抗體(抗原)引起的質量、密度和粘度等性質的變化,它兼具有壓電質量響應的高靈敏性和生物化學反應的高特異性。
  19. Surface plasmon resonance immunosensor is a relatively new immunoassay technique and has been receiving more and more attention in recent years. however, a major disadvantage of spr for bioanalytical applications is that low concentration or low molecular mass analytes could not be detected directly. therefore, it is a challenging task to develop strategies for improving the detection limit sensitivity of spr. in this paper, authors present a novel strategy for improving the sensitivity of spr immunosensing using streptavidinbiotinylated antibody complex. it is proven that the amplification strategy causes a dramatic improvement of the detection sensitivity. this amplification strategy is based on the construction of a molecular complex between streptavidin and biotin labeled protein. the complex can be formed in a crosslinking network of molecules so that the amplification of response signal will be realized due to the big molecular size of complex

    將鏈霉親和素-生物素系統用於表面等離子體共振免疫傳感的信號放大,實時檢測了人免疫球蛋白g higg的蛋白濃度。發生免疫反應的傳感片和生物素化抗體反應后,傳感片表面的一層生物素分子隨后與鏈霉親和素-生物素化抗體復合物中的鏈霉親和素的活性位點發生親和反應,從而使傳感片表面特異健合的物質質量顯著增加,大大提高了免疫檢測的靈敏度和檢測限。免疫反應經放大后,可檢測0 . 00510g ml濃度區間內的higg 。
  20. Experiment indicates that the sensor has a series of virtues, such as high sensitivity to aldehyde, good selectivity and reappearance, very short response time and stable performance, compared with ib processed before, it is easier to regenerate and has much longer lifetime

    該qcm傳感器,在液相中都表現出了對甲酸良好的響應敏感特性,在線性度、靈敏度、穩定性與重現性等方面均優良。有望用於對甲酸的在線檢測。
分享友人