  1. Abstract : there are only two set values ( 30, 45 ) for interior angle of the stimulated directional power relay as the protection in phase to phase short circuit fault. an accurate setting formula for interior angle of the microprocessor - based directional power relay as the protection in phase to phase short - circuit fault is proposed and analyzed, users can set as a calculation value or at least an optimum in the formula. therefore the operation sensitivity and reliability of the directional relay would be improved greatly. the opinion is new and practical

    文摘:保護相間短路的模擬式功率方向繼電器內角的整定值只有兩個( 30 、 45 ) ,用戶只能在這兩個值中選其一;分析並提出了保護相間短路的微機型功率方向繼電器內角的準確整定計算公式,用戶可以整定為該公式的計算值或至少為最合理的值,從而能顯著提高方向繼電器的動作靈敏度及可靠性,具有新見解及應用價值。
  2. In verifying of relay protection sensitivities, a network portioning method combining with graphic interface is proposed. it can online track the varieties of network, accordingly it can satisfy real - time and emulation analysis of topological configuration. with the real - time network configuration and nodal admittance matrix analyzed, the short - circuit calculation is carried out ; by means of an expert system, the verification of protection sensitivities has been achieved

    在網路拓撲在線快速跟蹤基礎上,進行實時結線分析並形成導納矩陣,同時將短路計算的理論運用於在線,將獲得的在線短路計算的結果同專家系統相結合進行保護靈敏度的在線校驗,最後通過友好的人機交互界面提供整個城市電網全部投運保護裝置的保護靈敏度狀況。
  3. This machine adopt the high - quality relay and the fleetness rectifier tube, the full - automatic short - circuit protection implement, operation nimble, use safety simplely reliably

    本機採用高品質繼電器及快速整流管,全自動短路保護器,操作簡單靈活,使用安全可靠。
  4. 6 ) the imitative exploration and analysis that wind - electricity field short circuit is how to influence the relay equipment of electricity net

    ( 6 )風電場短路電流對電網繼電保護影響的初步分析。
  5. So relay protection ca n ' t detect fault. this is likely to burn transformer if do n ' t take any measures after turn to turn short - circuit

    繞組匝間短路后仍然能帶滿負荷繼續運行,但是如果不採取相應的措施,故障將會進一步擴大,嚴重者至燒毀變壓器,造成巨大的經濟損失。
  6. To the exploration, the author studies sailimu and buerjin wind - electricity field. the study shows the short circuit proportion supplied by wind - electricity is very high, so the wind - generator can " t be treated as a simple equipment that assumes energy, nor a simultaneous generator, if as an unsimultaneous generator, the short circuit will be different when the capacity changes, as a sequence, the relay will be influence too

    以上研究結果表明:風力發電機提供的短路電流在短路電流中占相當大的比例,因此不能將風力發電機作為簡單負荷處理,也不能視為同步機處理,即使作為異步機處理,當採用容量不同時,短路電流大小也有變化,因此,也就直接影響繼電保護的整定計算。