  1. Then the paper uses the same typical four network operating conditions as the primary given conditions and when adding one set of the parallel capacitor bank, changing the 330 / 220kv transformer tap changer position step by step to change the transformer ration, through this study methods this paper found out all the optimized combination of the tap changer position and the amount of input reactive power, also obtained four sets of the 330kv, 220kv and hokv s / s bus voltage and the active and reactive power losses changing curves. through analyzing the optimized combination control curve and the network power flow, the paper generalizes the rules as following : the chief measure of coordinative control is inputting shunt reactor in chengxian s / s in winter time both in the planning year of 2010 & 2005 ; in summer time in planning year of 2010 the chief measure is to input proper shunt capacitor

    本研究通過分析所獲得的最優綜合控制組合曲線及電網潮流,總結出了如下規則:隴南電網在2005年及2010年冬大、以及2005年夏小運行方式下,綜合控制應以成縣變投入適量並聯補償電抗器作為主要措施;在2010年夏小運行方式下則投入適量並聯補償電容器作為主要措施,再輔助以選擇合適的主變有載調壓分接頭來調節,達到控制網內無功潮流分佈合理、各變電站母線電壓在理想的范圍內時電網有功損耗最小,從而也提高了電網安全運行水平及供電質量。
  2. The study bases on the four operating conditions of which the longnan network will be implemented in the year of 2005 and 2010. first, this paper calculates the power flow distribution that including the line charging reactive power and input of the low - voltage shunt reactor in chengxian s / s. assumed that the bus voltage of tianshui s / s and bikou power plant to be constant, the study count the voltage level of the 330kv and 220kv bus - bar when the 330 / 220kv transformer in standard tap changer position. in order to set control rules

    本文基於隴南電網在規劃發展水平年2005年及2010年的四種可能的運行方式下及潮流條件,計算出了計入線路充電無功及投入成縣變低壓並聯電抗器后的潮流分佈,在設定甘肅大網側及碧口電廠側母線電壓恆定條件下,計算了330kv及220kv主變在有載調壓標準分接頭變比下的330kv及220kv母線電壓水平。
  3. In order to ensure the whole system operate economically, power department equip transformer with onload tap changer and shunt capacitors for most distribution substations, according to the operating condition, adjusting the position of transformer taps and capacitors can control the variation of voltage and reactive power exchanger of distribution substations and power system in certain extent

    為確保整個系統運行經濟性,降低網損,電力部門在大多數變電站配置了有載調壓變壓器和並聯補償電容器組,根據運行情況適當調節變壓器分接頭的位置和投切並聯補償電容器組,可以降低電壓變化和變電站與系統的無功交換控制在一定的范圍內,確保供電質量和電網運行的經濟性。
  4. This paper mainly discusses a control method of substation voltage and reactive power. in order to get suitable decision for one day 24 hours tap - transformer ' s step switch and shunt capacitor switch, an approach of substation voltage and reactive power control on the basis of the combination of artificial neural network ( ann ) reactive power forecasting and evolutionary programming optimal decision - making is put forward

    論文主要研究變電站的電壓/無功控制決策問題,為了確定一天24小時內合適的有載調壓變壓器分接頭位置和並聯電容器投切狀態,提出一種基於人工神經網路的無功負荷預測和進化規劃優化決策相結合的變電站電壓和無功的綜合控制決策。
  5. Through analyzing the mathematical model of two winding transformer, the effect after on - load tap changing on voltage and reactive power balance at each side, effect of shunt capacitor compensation on voltage and reactive power balance in substation the relation between transformer tap adjusting and shunt capacitor switching in practical grid operation were discussed

    摘要通過對兩卷變壓器的數學模型進行分析,討論了兩卷變壓器抽頭調整后,變電站各側電壓及無功功率的變化;無功補償對變電站各側電壓及無功功率的影響;實際電網生產運行中,無功補償與變壓器抽頭的配合調整。