spectral calibration 中文意思是什麼

spectral calibration 解釋
光譜校準
  • spectral : adj. 1. 鬼的;鬼怪(似)的。2. 【物理學】光譜的。
  • calibration : n. 1. 測定口徑。2. 刻度,標度,劃度數。3. 校準;標準化。
  1. In the regions of astrodome physics, solid physics, photochemistry and medicine, measurement and calibration of spectral irradiance of ultraviolet and vacuum ultra - violet have become more and more important research means and instrument

    紫外和真空紫外光譜輻照度的測量和定標,在天體物理、固體物理、光化學及醫藥學等領域中已成為越來越重要的研究手段和工具。
  2. Calibration for relative spectral responsivity of multichannel radiometer

    通道式輻射計的相對光譜響應率定標
  3. First, the apparatus of spectral irradiance calibration is set up, and ultraviolet spectrum band uses a standard lamp offered by standard metrological institute of china, while vacuum ultraviolet spectrum uses a deuterium transfer lamp

    地面輻射定標分為光譜輻照度定標和光譜輻亮度定標。光譜輻照度定標中選用了鹵鎢燈作為250nm 400nm標準光源,氘燈作為200nm 300nm的傳遞光源。
  4. There are three mathematical models of multi - spectral thermometry based on calibration factor, brightness temperature and reference temperature respectively

    多光譜輻射測溫法的數學模型有基於檢定常數的數學模型、基於亮度溫度的數學模型和基於參考溫度的數學模型。
  5. The spectral calibration of the small spectrometer has been completed and resolution, wavelength precision and bandwidth of it are all determined

    進行相關的光譜測量實驗,完成了光譜儀的光譜標定及解析度、波長精度和帶寬等性能指標的測定。
  6. For the spectral radiance calibration of solar ultraviolet spectrum monitor, a basc > 4 diffuser is used, and a more accurate calculation for spectral radiance response is given by a integral formula. process of download signal data from solar ultraviolet spectrum monitor on spaceship obtains measurement results of solar ultraviolet spectral irradiance and solar backscatter spectral radiance

    根據太陽紫外光譜監視器的地面標定結果,對從神舟三號上下載的測量數據進行處理獲得了地外太陽紫外光譜輻照度和地球大氣後向散射光譜輻亮度,與國際上的測量結果對比相對誤差在10 %以內。
  7. Graphically - oriented local multivariate calibration modeling procedures called interval partial least - squares ( ipls ) was applied to select the efficient spectral regions that provided the lowest prediction error

    本研究提出一種間隔偏最小二乘法的農產品近紅外光譜譜區選擇方法,並將其應用於建立蘋果糖度近紅外光譜模型。
  8. Standard lamp and diffusers are very important calibration elements, in chapter three, first uv and vuv radiometric standard for calibration are introduced. then the fabrication and characteristics of baso4 diffuser and alminium diffuser are researched, the baso4 diffuser ' s hemispheric reflectance and bi - directional reflectance distribution function were measured and compared with lambtian surface, and the deviation from that of lambtian surface is given. in the experiment, al diffuser ' s brdf is researched, obtain the change of spectral characteristic of al diffuser, compare al diffuser ' s brdf before and after coated with al + mgf2, and different al diffusers with different surface roughness

    鋁漫反射板作為一個漫反射光學元件安裝在太陽紫外光譜監視器的入射狹縫前,太陽紫外光譜監視器在軌測量時,太陽輻射入射到鋁漫反射板后進入入射狹縫,光譜輻照度的角度是變化的,本章測量了鋁漫反射的相對雙向反射分佈函數,研究了鍍膜( al + mgf _ 2 )前後光譜反射率的變化,漫反射的光譜特性及漫反射板表面粗糙度對相對雙向反射分佈函數的影響,使得測量數據反演成為可能。
  9. Standard practice for monitoring the calibration of ultraviolet - visible spectrophotometers whose spectral slit width does not exceed 2 nm

    光譜狹縫寬度不超過2nm的紫外線-可見光分光光度計的校準監測的標準實施規程
  10. In the dissertation, an in - depth study is carried out by the author by synthesizing multi - disciplinary knowledge on the following topics : the abstraction of weak spectral signal, the optimal pathlength measurement condition, the optimization of regression method, the enhancement of multivariate calibration model robustness and the physical explanation of measurement results are studied

    本論文綜合多學科的知識深入研究了從重疊復雜的光譜中提取微弱的化學成份信息的方法,最佳測量條件的設計,建模方法的優化,校正模型穩健性的提高以及測量結果的物理解釋等關鍵技術基礎問題。
分享友人