  1. This article has studied the deficiency and shortcoming of various kinds of methods of the parameter measurement of transmission line at present, proposed the measurement under operation on the basis of gps, researched gps application way and error that may appear in the power system synchronal sampling, put forward the parameter computing technology based on the information of both sides of transmission line, which solved some problems that exist in the parameter measurement, especially the problem that exist in the zero - sequence parameter measurement of transmission line with mutual inductance

    本文研究了目前輸電線路參數測量的各種方法,分析了其中存在的不足和缺點,提出了基於gps的輸電線路參數在線測量方法,研究分析了gps在電力系統同步采樣中的應用方式以及可能出現的誤差,在同步采樣的基礎上提出了基於雙端信息的線路參數計算方法,較好地解決了輸電線路參數測量中存在的一些問題,尤其是多回互感線路零序參數測量困難的問題。
  2. The development of a visual short circuit software under ptcad2000 is presented in this paper, as well as the system structure, the definition of the data structure, the interface to ptcad2000, the conversion of the original wiring diagram of power network to calculable power network, the implement of three sequence network, the implement of impendence matrix and admittance matrix of power network considering the zero sequence mutual inductances among lines, and the implement of short circuit calculation by using computer

    本文介紹了在ptcad2000平臺下短路電流可視化計算軟體的開發。介紹了軟體的系統結構、數據結構定義、與ptcad2000平臺的介面、電力系統原始接線圖轉成等值可計算網路、序網的生成、考慮零序互感線路阻抗時電網導納矩陣和阻抗矩陣的生成,以及故障點短路電流計算的計算機實現。
  3. It includes four criterions of locating fault point ? “ transient zero sequence current amplitude law ”, “ stable base wave zero sequence current phase law ”, “ stable seventh harmonic zero sequence current phase law ” and “ s injection law ”. pointing out how the law locate the fault point to minimal fault section by applying these criterions gradually. the law will not only make up the blemishes existing in current methods for single - phase fault location in small current grounding system, but also locate the fault point to minimal fault isolating unit on fault line

    該方法通過將所包含的四個定位判據- 「暫態零序電流幅值法」 、 「穩態基波零序電流方向法」 、 「穩態7次諧波零序電流方向法」和「 s信號注入法」 -進行有選擇地遞進使用,不僅有效彌補了目前已有小電流接地系統單相接地故障選線的缺陷,更將故障定位在故障線路最小故障區段。
  4. Unified power flow controller ( upfc ) is one of the most powerful and most promising controllers of facts. if we use upfc to control the transmission parameters, terminal voltage, line impedance and phase angle in normal situation and use it to compensate zero sequence and negative sequence currents when one of transmission lines is cut off, we can implement two phases operating in high voltage transmission lines, which can improve stability and reliability for the transmission system

    統一潮流控制器( upfc )是功能最強、最具發展潛力的靈活交流輸電系統( facts )控制器之一,如果在常規條件下,用upfc實現輸電線路的電壓調節、移相、潮流控制、阻尼振蕩等功能,在發生單相永久性接地或單相斷路故障時,由傳統的三相跳閘改為單相跳閘,用upfc的並補來濾除兩端系統的零序和負序電流,用upfc的串補來提高輸電線的傳輸功率,以實現兩相長期運行,那麼輸電系統的穩定性、可靠性將大大提高。
  5. Abstract : zero sequence directional power protection is widely used in neutral directly grounded system

    文摘:在大電流接地系統中廣泛採用著零序功率方向保護。
  6. Firstly, we analyze the transient and steady character of single phase high - impedance grounding fault. secondly, based on wavelet analysis on checking mutational signal and direction high frequency protection theory, utilizing zero sequence current and module current, this paper provides a new scheme including fault starting element, fault phase selection element, directional element and main criterion. this scheme can bear high impedance and is immune to system surge and frequency warp, which gets over the shortcoming of the lack of sensitivity

    由於現有的保護方案無法快速有效地切除此類故障,本文在詳細分析了單相高阻接地故障的穩態和暫態特性的基礎上,從小波分析原理出發,利用小波變換檢測突變信號的原理,以零序電流、模電流等為研究對象,結合方向高頻保護的原理,設計了一套包含啟動元件、選相元件、方向元件、主保護的保護新方案。
  7. According to zero sequence voltage distribution from system zero sequence impedance to shunt reactor zero sequence in zero sequence circuit, the zero sequence voltage at the terminal of shunt reactor and the zero sequence compensating voltage at neutral are compared in the scheme

    即根據零序網路中零序電壓在系統零序阻抗和電抗器零序阻抗上的分佈情況,通過直接比較電抗器首端零序電壓與補償到電抗器末端中性點的零序補償電壓的幅值大小,來判別電抗器匝間故障。
  8. It has the characteristics of fault component relays such as being immune to the load and the system operating mode and the zero sequence components required by the relay can he easily acquired and available for a long time

    由於採用零序電量作為判斷依據,新方法具有受兩側電源角度的影響小,且受負荷、系統運行方式的因素影響小的特點。
  9. In this thesis, the zero correlation zone ( zcz ) or generalized orthogonal ( go ) sequences are applied to direct - sequence cdma ( ds - cdma ) systems, and the corresponding system performance are analysed. topics on the correlation property analysis of hadamard walsh ( wh ) sequences, go sequences, and loosely synchronous ( ls ) sequences are performed, and the system model and performance evaluation of single - cell and multi - cell synchronous cdma ( s - cdma ) systems employing go sequences, and the applications of go sequences in quasi - synchronous cdma ( qs - cdma ) systems are elaborated

    本文研究了零相關區( zcz )或廣義正交( go )序列在直接序列碼分多址( ds - cdma )系統中的應用並給出了系統性能分析結果,包括hadamardwalsh ( wh )序列集、廣義正交序列集與鬆散同步( ls )序列集相關特性分析,採用廣義正交序列的單小區與多小區同步cdma ( s - cdma )系統模型與性能分析,以及廣義正交序列在準同步cdma ( qs - cdma )系統中的應用等問題。
  10. Further, the methods are proposed to compare and summarize for choosing fault line and detecting distance in neutral ungrounded system. subsequently, the characteristics of zero sequence current and transient courses are introduced and analyzed

    接著對小電流接地系統單相接地故障時零序電流的暫態過程及特點做了介紹和分析。
  11. Within the specified time limit, the strategy determines and implements an optimal feed - forward control sequence to the system, swings up the double inverted pendulum from its hanging position, and achieves zero speed state at the upright position

    該策略通過在規定的時間內向系統施加一前饋控制序列,使上、下擺桿從自然懸垂位置擺到倒立點位置並使速度為零。
  12. According to the present actual underground power system which neutral point is grounded through arc suppression coil in many supper big shaft, the development history and present situation of synthetic protection system used in hv flameproof switchgear are reviewed, and on the basis of analyzing the problems existed in high voltage flameproof switchgear, the selective leakage protective method based on the detecting harmonic direction of zero sequence current as well as the value of zero sequence voltage is proposed in this paper, and at the same time, harmonics extracting schematic and transforming circuit are also designed

    本文深入系統地研究了基於intel80c196kb單片機控制的6kv防爆開關綜合保護系統,主要內容如下:針對大型及特大型礦井供電系統中性點普遍採用消弧線圈接地方式的現狀,回顧了國內外礦用高壓防爆開關保護系統的發展歷史,分析了目前國內高壓饋電開關保護系統所存在的問題,提出了「基於零序電壓基波啟動,五次諧波功率方向比較」的選擇性漏電保護原理,設計了相應的五次諧波提取電路和功率方向鑒別電路。
  13. But due to the existence of the fault resistance, the branch current, the zero sequence mutual coupling and so on, the apparent impedances and protection scope of distance protection will change, thereby affecting the performance of distance protection and the safety operation of power system

    然而,由於過渡電阻、分支電流和零序互感等因素的影響,會改變距離保護測量阻抗的大小,造成距離保護動作范圍的擴大與縮小,從而影響距離保護的性能,威脅電力系統的安全運行。
  14. This paper brings forward that asvg is capable of compensating harmonic, negative sequence and zero sequence currents. so asvg can synchronously compensate the reactive current and harmful currents in three - phase four - wire unbalanced system

    本文提出靜止無功發生器還具有抑制諧波和濾除負序、零序電流的能力,從而可以用於對三相四線制不平衡系統同時進行無功補償和有害電流濾除。
  15. In the electric power system of neutral point effectively, if parameter is not symmetric, the zero - phase - sequence current will appear

    在中性點有效接地系統中,如果參數不對稱就會產生零序電流。