匝間試驗 的英文怎麼說

中文拼音 [jiānshìyàn]
匝間試驗 英文
interturn test
  • : [書面語]Ⅰ量詞(周; 圈) circle; circumference; turn; loop; wrap Ⅱ動詞(環繞) surround; circleⅢ形...
  • : 間Ⅰ名詞1 (中間) between; among 2 (一定的空間或時間里) with a definite time or space 3 (一間...
  • : 名詞(古代占卜用的器具) astrolabe
  • : 動詞1. (察看; 查考) examine; check; test 2. (產生預期的效果) prove effective; produce the expected result
  • 試驗 : trial; experiment; test
  1. There are over 80 sets test apparatus in tech - innovation centre, including : anechoic chamber, vibration tester, vibration measurement analysis, impact instrument, constant temperature and humidity facilities. salt spary test case, circle insulation withstand voltage tester, insulation resistance tester, withstand voltage tester, electric lead tester, electrical leakage tester, earth resistance tester, chassis dynamometer, chassis dynamometer control system, high stability dc resistance tester, electrical capacity tester, temperature rise test system

    中心擁有各類分析測儀器和裝置80餘臺套,包括:消音室振動臺噪聲振動測分析系統沖擊儀恆溫恆濕實儀鹽霧耐壓分析儀絕緣電阻分析儀對地耐壓分析儀泄露電流測儀對地電阻測儀測功機測功機控制系統高精度直流電阻測儀電參數測儀帶電溫升測儀復合式三坐標測量儀萬分投影儀及電功測分析系統等。
  2. Test specification of the interture insulation on armature winding for dc machines

    直流電機電樞繞組絕緣規范
  3. The analytical results show : the turn - to - turn protection with integrated circuit for geheyan hydropower plant can not wholly avoid misoperation in the system ' s oscillation process in accordance with its principle ; for the turn - to - turn protection with microcomputer of the gaobazhou hydropower plant, there also exists some problem in accordance with dynamic model test and theoretical analysis

    通過分析指出,對于隔河巖水電廠的積體電路型保護,在系統振蕩過程中該保護裝置在原理實現上就不能避免誤動發生;對于高壩洲水電廠的微機型保護,通過動模和理論分析,同樣發現其存在一定問題,不能完全滿足現場要求。
  4. Guide for testing turn insulation of form - wound stator coils for alternating - current electric machines

    交流電機模繞定子線圈絕緣的指南
  5. Guide for testing turn - to - turn insulation on form - wound stator coils for alternating - current rotating electric machines

    交流旋轉電機用模繞定子線圈的絕緣指南
  6. Turn to turn test

    絕緣
  7. Test limits of the interturn insulation on random wound winding for ac low - voltage machines

    交流低壓電機散嵌繞組絕緣.限值
  8. Test methods of the interturn insulation on random wound winding for ac low - voltage machines

    交流低壓電機散嵌繞組絕緣.方法
  9. Taking the geheyan and gaobazhou hydropower plants for examples, the problem of turn - to - turn protection of generators is discussed and analyzed by combining with the implementation scheme of principle, actual operation situation and situation of dynamic model test

    摘要以隔河巖水電廠和高壩洲水電廠為例,結合原理實現方式、實際運行情況、動模情況,對發電機保護進行了較為深入的分析探討。
  10. Power utility local test indicate that new characteristic is effective to monitoring transformer especially transformer windings

    結果表明,該特徵量對監測變壓器繞組故障特別是短路故障是行之有效的。