接地故障 的英文怎麼說

中文拼音 [jiēdezhàng]
接地故障 英文
earth crepe
  • : Ⅰ動詞1 (靠近;接觸) come into contact with; come close to 2 (連接; 使連接) connect; join; put ...
  • : Ⅰ名詞1 (事故) event; incident; happening; accident 2 (原因) cause; reason 3 (朋友; 友情) fr...
  • : Ⅰ動詞(阻隔; 遮擋) block; hinder; obstruct Ⅱ名詞(遮擋物) barrier; block; obstacle
  • 接地 : [電學] landing; body; ground connection; electrical grounding; grounding; earthing; earth; ground...
  • 故障 : hitch; breakdown; stoppage; fault; faulting; accident; blunder; bug; conk; failure; impairment; i...
  1. The two - point to earth short fault may cause short currents whic h can lead to serious accident. so it is necessary to monitor the state of field windings of turbo - generator and detect the kind of fault and predict its inclination. thus the security level of power system will be improved

    由於發電機轉子兩點接地故障時會產生較大的短路電流,導致惡性事的發生,因此對發電機轉子繞組進行狀態監測,判斷短路的形式和趨勢是十分必要,有助於提高系統安全運行水平。
  2. Numerous preprogrammed and user - defined time current curves for sensing phase or ground faults. - three independent recloser interval times

    對于相間和接地故障,有很多條預定義的或者用戶可定義的時間電流曲線可供選擇。
  3. On dealing with earth fault of stator windings in generators

    發電機定子繞組接地故障處理
  4. New designed auto tracing arc eliminating device based on this technique contents more technology, which has sample circuit, wide tuning scope, quick response and low noise. this paper firstly introduces neutral grounding histroy. by analyzing the syntony grounding theory, the transient and stable process of one - phase grounding fault, the threaten to secure run of power system and the importance of exact compensation for capacitive current are cognized

    論文中首先介紹了中性點方式的發展過程,通過對諧振原理和單相接地故障的暫態、穩態分析,認識到接地故障對系統安全運行的危害,通過消弧線圈對電容電流的迅速準確補償是減小危害的最主要手段。
  5. The single - phase grounding fault frequently occurs in neutral ungrounded system, the fault line and fault location must be found to avoid a phase - to - phase short as soon as possible

    單相接地故障在小電流系統中出現的比較頻繁,此時必須盡快找到線路以及大致的點,以避免兩相對短路。
  6. The second class cable ? suitable for more the earthing ? block time and more better insulated performa

    第二類? ?用於接地故障時間更長的系統及對電纜絕緣性能要求較高的場合。
  7. Ground - fault circuit interrupters

    接地故障電路斷路器
  8. Ground fault protection

    接地故障保護
  9. Ground fault protection this function trips ( opens ) a circuit breaker or sounds an alarm in the event that there is an electrical fault between one or more of the phase conductors and ground ( earth )

    接地故障保護當一個或多個相導線與之間出現電氣時,接地故障保護通過跳脫斷路器或報警來示警。
  10. To resolve the situation that the sensitivity of present ground fault protection schemes is low for the large - sized hydro - generators, a kind of protection scheme based on the fault component of third - harmonic voltage and two kinds of protection scheme based on the fault component of zero - sequence voltage at the terminals and neutral are developed, and they can obtain higher sensitivity and reliability and provide 100 % protection for the stator windings. the influence of noise on the stator ground fault protection based on the local modulus maximum of wavelet transform is analyzed

    針對目前大型水輪發電機定子繞組單相保護靈敏度偏低的問題,通過分析單相接地故障后機端和中性點零序電壓的變化特點,提出了一種基於機端和中性點三次諧波電壓分量和兩種基於機端和中性點零序電壓分量的高靈敏度、高可靠性保護方案,並實現定子繞組的100 %保護。
  11. The ground faults in the generator stator are by far common faults to which generators are subjected. internal short - circuit faults, which may immediately damage generator, are always preceded by the ground faults. the possibility of internal fault and damages caused by it can be decreased largely if the stator ground fault protection reliably and sensitively operates

    定子繞組單相接地故障是發電機最常見的一種,而且往往是更為嚴重的繞組內部短路發生的先兆,定子繞組單相保護的可靠與靈敏動作可以大大降低內部短路的發生幾率,減少造成的損失。
  12. The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance

    爭議點主要是在10kv電網接地故障的形式、消弧線圈的應用范圍、兩種運行方式供電可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以電纜為主的城區10kv電網中性點方式的選擇問題進行研究。論文首先對10kv電網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變電站10kv電網的實際參數來建立數值計算模型,在考慮了電網電容電流變化、中性點電阻取值大小、電阻值變化等多種影響因素的情況下,對中性點經消弧線圈和經小電阻方式下電網的過電壓水平和點短路電流大小進行了數值計算,其計算結果與電科院所作現場試驗進行了比較。
  13. Location using one - terminal data for double phase - to - earth fault on non - direct ground neutral system

    非直系統兩相接地故障的單端測距
  14. In this paper, the meaning of research and development status of the small current grounded line detection devices. the current measurement principles, the relevant structures and reasons for their success or failure of the devices in lining power network are analyzed. then, the principles of wavelet analysis, resonance wavelet analysis and energy analysis are detailedly introduced

    本文簡述了小電流選線研究的重要意義,介紹了小電流系統單相接地故障選線的發展狀況,及濟寧電網現有選線裝置的測量原理和結構,分析了各種選線模式成功與失敗的原因。
  15. The searching and repairing methods for high for high speed grounding accident of rotor winding in generator no, 5 have been briefly described

    摘要簡述了5號發電機轉子高速接地故障的查找和檢修處理方法。
  16. Specification for non - incendive low voltage control interlock and low voltage earth fault monitoring circuits for use in mines

    礦用非激勵低壓控制聯鎖電路和低壓接地故障監控電路規范
  17. The fault line selection matter in such system is one of the problems, which have not solved successfully for many years

    小電流系統單相接地故障選線是多年來一直未能很好解決的一個難題。
  18. Then the idea of integral control of automatic resonance and single - phase earth faulted line selection was put forward

    並在此基礎上給出了補償電網中消弧線圈自動調諧與單相接地故障選線一體化的綜合控制思路。
  19. This paper researches the non - direct - grounded system fault detection from software arithmetic view, whose main content is as follows : the paper analyses the system running characters before and after fault. and the paper analyses the fault transient signal and fault steady signal and all parts in fault steady signal after the single line - to - earth fault occurs, and discovers the fault laws and appearance of fault signal. the analyzing of the fault laws and fault phenomenon of non - direct - grounded system all above is the base of analyzing arithmetic

    本文針對小電流系統選線的問題,從軟體演算法的角度進行了研究,主要內容如下:對小電流系統前和后系統的運行特點進行了分析,並且對小電流系統發生單相接地故障后,暫態信號、穩態信號以及穩態信號的各種成分進行了深入的分析,找到了的規律以及其信號的表現形式,為對各種演算法的分析比較打下了基礎。
  20. Line - to - ground fault location maintains unresolved to power distribution networks for a long time

    而配電網的單相接地故障定位長期以來是難以解決的課題。