接地電壓 的英文怎麼說
中文拼音 [jiēdediànyā]
接地電壓
英文
voltage to ground- 接 : Ⅰ動詞1 (靠近;接觸) come into contact with; come close to 2 (連接; 使連接) connect; join; put ...
- 電 : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
- 壓 : 壓構詞成分。
- 接地 : [電學] landing; body; ground connection; electrical grounding; grounding; earthing; earth; ground...
- 電壓 : voltage; electric tension; electric voltage
-
Seven test points enable a check of the output voltages and currents, by supplying proportional voltages relative to gnd
七個測試點通過對地的比例電壓能夠間接測量出輸出的電壓和電流。But when fault was occurred, sometimes there would be great loss. for the reason, the paper put forward a microcomputer bus protection scheme suit for mv or lv power system with low current grounding based on the great researching about the working theory of current bus protections and the characteristic of mv or lv system with low current grounding. based on it, the paper has designed the platform of the hardware and the software programs
針對國內目前中、低壓電網大都未裝設母線保護裝置,發生故障不能及時切除時造成很大損失的狀況,本文在廣泛研究當前主流的母線保護動作原理並認真分析了中、低壓小電流接地系統特點的基礎上,提出了一套適合中、低壓微機母線保護裝置的研製方案,並據此選擇、搭建了硬體平臺,設計了軟體功能程序。The products is of high water hydrophobe device usedin suitable and has the characteristics of aging resistance, resistance, tracking resistance, and corrosive resistance. it can withstand high bent load, strong impact force fn12 - 12 series indoor use high voltage load switch fn12 - 12 and fn12 - 12r is of three phases indoor use ac high voltage load switch for breaking and making the circuit of 50hz, 12kv system under rated loading
Fn12 - 12和fn12 - 12r組合電器是額定電壓12kv額定頻率50hz的三相高壓開關設備用於分合負荷電流閉環電流空載變壓器和電纜充電電流關合短路電流配裝接地開關的負荷開關,可以承受短路電流On the other side, measuring errors of grounding resistance and solution of current voltage electrodes reversing has been compared with horizontal two layers and vertical delaminating ( three layers soil )
比較分析了電流電壓極反向布置、在水平雙層和垂直分層或三層土壤結構中接地電阻測量的誤差和解決辦法。The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance
爭議點主要是在10kv電網接地故障的形式、消弧線圈接地的應用范圍、兩種運行方式供電可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以電纜為主的城區10kv電網中性點接地方式的選擇問題進行研究。論文首先對10kv電網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變電站10kv電網的實際參數來建立數值計算模型,在考慮了電網接地電容電流變化、中性點電阻取值大小、接地點接地電阻值變化等多種影響因素的情況下,對中性點經消弧線圈接地和經小電阻接地方式下電網的過電壓水平和接地點短路電流大小進行了數值計算,其計算結果與電科院所作現場試驗進行了比較。The influences of vertical grounding electrodes on grounding resistance, step and touch voltages were analyzed numerically
採用數值計算方法分析了垂直接地極對接地系統的接地電阻、接觸電壓及跨步電壓等的影響。It creates the model of layer soil by using the cdegs software, analyses the resistance error which is measured by traditional three - poles way, measures the grounding grids resistance and soil resistance rate of hejin power plant, creates the electromagnetic model of layer soil and grounding grids model of hejin power plant, calculates the step voltage > touch voltage n voltage distribution of earth surface in fault of hejin power plant. in the end, it compares the measuring value and calculating value of grounding grids resistance in hejin power plant
本文利用cdegs軟體建立分層土壤接地模型,對傳統三極法測量接地電阻誤差進行分析;對河津電廠接地網接地電阻和土壤電阻率進行測量;建立河津電廠分層土壤電磁模型和接地網模型;計算河津電廠接地網電阻和事故狀態下跨步電壓、接觸電壓和地表電位分佈;最後對河津電廠接地網電阻實測值與計算值進行比較分析。Electronic co., ltd., a private hi - tech company, professionally makes and markets electronic instruments and gauges, such as digital torque tester, bottle cap torque tester, voltage resistance tester, grounding resistance tester, leakage current tester, insulation resistance tester and etc. lankers quality instruments and gauges are characterized by well - designed structure, high reliability and stability and outstanding performance and are well sold to users in the industries of home appliances, motorcycle, automobile, motor and pharmaceutical
市藍光電子有限公司是一家集科研生產銷售於一體的高科技民營企業,公司擁有雄厚的技術實力,以卓越的設計能力,完備的工藝控制和完善可靠的檢測手段,向用戶提供高性價比的電子測量儀器。主要產品有:數字扭力測試儀系列瓶蓋扭力測試儀系列耐電壓測試儀,接地電阻測試儀,泄漏電流測試儀,絕緣電阻測試儀等安規測試儀系列。The model considers peak value of lightning current, tower grounding resistance, tower style, line surge impedance, power frequency voltage and distance between towers
模型中考慮了雷電流幅值、桿塔沖擊接地電阻、桿塔具體形狀、尺寸、桿塔波阻抗、工頻電壓及檔距等因素的影響。The results show that the vertical grounding electrodes can effectively decrease grounding resistance, step and touch voltages of the grounding system and reduce the influence of seasonal factors on the grounding system
分析表明,增設垂直接地極能有效減低接地系統的接地電阻、減小發變電站的接觸電壓和跨步電壓、減小季節因素對地網安全性的影響。Leeec may produce the special transformer according to the clients requirements including : commutate transformer ; furnace transfo - rmer ; earthing transformer ; isolation transformer
遼寧易發式電氣設備有限公司可根據客戶需要,生產各種電壓等級特種變壓器,主要有整流變壓器電爐變壓器接地變壓器隔離變壓器等。The calculation of the selection of the neutral - point earthing - transformer of the generator shows that the selection of its parameters should be matched with one - point earthing protection of the stator of its generator
對發電機中性點接地變壓器的選型計算表明,其參數選擇必須與發電機定子一點接地保護相配合。Firstly, the paper introduced the commonly hardware configure of microcomputer relaying and the function of every module of industry controlling computer std90386. secondly, the paper introduced several types busbarprotection which was commonly installed on electric power system and the characteristic of mv or lv system with low current grounding. based on it, the paper put forwards the theory of percentage - restraint differential relay. after that, in the discussing every problems of the relaying working the paper put the emphasis on the negative effect of the ct saturation and countermeasure
本文首先介紹了微機保護裝置的一般硬體配置以及作為裝置硬體平臺的std90386工控機各組件模板的功能,然後分析了目前電網系統裝設的母線保護的各種類型以及中、低壓小電流接地電網的特點,在此基礎上分析、介紹了作為本保護動作原理的「比率制動式差動保護」原理。In the 3 ~ 35kv power supply system of our country, the large part is the not solidly earthed neutral system. when the single - phase earthed phenomena happens in this system, this electric power network can run with failure. and in this way the operated cost can reduce greadty. and at the same time the power supply systemic dependability can be improved. but when the single - phase earthed current is large, this electric power system can engender easily arc earthed overvoltage and interphase short circuit by this means
在我國10 35kv供電系統中,主要為中性點非直接接地系統,這種系統在發生單相接地時,電網仍可帶故障運行,這樣可以大大降低運行成本,提高供電系統的可靠性,但這種供電方式在單相接地電容電流較大時容易產生弧光接地過電壓和相間短路,給供電設備造成了極大的危害。By analyzing the refraction 、 reflection process of fault transient current traveling wave of high voltage and characteristics of refraction 、 reflection coefficient systematically, a new fault location method of single ended traveling wave is presented. it can not only identify the reflection wave for fault location efficiently, but also not be affected by the structure and length of line. fault earthed resistance 、 fault type 、 system impedance and can locate fault in adjacent areas accurately
論文深入地分析了高壓線路故障暫態電流行波的波折、反射過程以及折、反射系數的特點,提出了新的單端行波故障測距方法,它不僅能夠有效地識別出測距所用的反射波,而且幾乎不受線路結構、長短、故障接地電阻、故障類型、系統阻抗的影響,在近區仍可以準確地進行測距;同時模擬阻波器的特徵,設計了低通數字濾波器,對通過了低通數字濾波器的暫態故障電流行波再次進行小波分析,並利用本文提出的單端行波故障測距方法進行故障定位,結論是所提出的測距方法在實際應用中仍是有效的。Electrical safety in low voltage distribution systems up to 1 kv a. c. and 1, 5 kv d. c. equipment for testing, measuring or monitoring of protective measures. part 5 : resistance to earth
最高可達1 kv交流電和1 . 5 kv直流電的低壓配電系統中的電氣安全性.試驗測量或保護測量監測用設備.第5部分:接地電阻If you were to leave a grounded cable stationary in an energized high - frequency electrode for a while, you would notice that the insulation is noticeably warmer where it made contact with the corona field
如果我們將一根接地電纜穩定放在施以高頻電極電壓的電極中一會兒?你將注意到與電暈有接觸的絕緣部分有明顯的變熱。Recurring to rnathematic figure and examples and aiming at such questions as unbalanced current and induced voltage and high frequency interference, this paper has not only researched anti - jamming ability and measuring process of both three - electrode method and four - electrode method which are combined with reverse phase method, but also summarized actual measuring experiences
通過數學推導和實例,圍繞消除地網不平衡電流、電壓極電流極引線問互感電壓、高頻干擾等問題,分析了三極法、四極法結合倒相法測量接地電阻的抗干擾能力和測量過程,並總結了實際測試經驗。Besides, it has been proved that four - electrode method is suitable for measurement of grounding resistance, which disposes current electrode and voltage electrode according to triangle. finally this paper has corrected one wrong parlance that inherent error exists in four - electrode method
通過理論和實踐證明了四極法適用於電流、電壓極按三角布置測量接地電阻,並糾正了其他文獻關於四極法存在固有誤差的問題,得出四極法的固有誤差和三極法一致的結論。The voltage of power supply is different depending on the country. please buy an ac power adaptor in the country / region where the radio is to be used
因為各國的電壓不同,故須在收聽廣播的國家/地區采購適于當地電壓的ac電源轉接器使用。分享友人