接地電流 的英文怎麼說

中文拼音 [jiēdediànliú]
接地電流 英文
earth current
  • : Ⅰ動詞1 (靠近;接觸) come into contact with; come close to 2 (連接; 使連接) connect; join; put ...
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : Ⅰ動1 (液體移動; 流動) flow 2 (移動不定) drift; move; wander 3 (流傳; 傳播) spread 4 (向壞...
  • 接地 : [電學] landing; body; ground connection; electrical grounding; grounding; earthing; earth; ground...
  • 電流 : current; galvanic current; electric current; electricity; current flow電流保護裝置 current protec...
  1. Single - phase earthed capacitance current automatism compensate device of 6kv electricity - net

    網單相的自動補償裝置
  2. New designed auto tracing arc eliminating device based on this technique contents more technology, which has sample circuit, wide tuning scope, quick response and low noise. this paper firstly introduces neutral grounding histroy. by analyzing the syntony grounding theory, the transient and stable process of one - phase grounding fault, the threaten to secure run of power system and the importance of exact compensation for capacitive current are cognized

    論文中首先介紹了中性點方式的發展過程,通過對諧振原理和單相故障的暫態、穩態分析,認識到故障對系統安全運行的危害,通過消弧線圈對的迅速準確補償是減小故障危害的最主要手段。
  3. Analysis of ungrounded neutral ac electric network insulation fault

    中性點不網絕緣故障分析
  4. On the other side, measuring errors of grounding resistance and solution of current voltage electrodes reversing has been compared with horizontal two layers and vertical delaminating ( three layers soil )

    比較分析了壓極反向布置、在水平雙層和垂直分層或三層土壤結構中阻測量的誤差和解決辦法。
  5. Harm of sing - phase grounding current and compensate method

    單相接地電流的危害及補償方法
  6. An integrative device of single - phase grounding line selection and grounding current compensation in distribution network

    網單相選線和接地電流補償一體化裝置
  7. The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance

    爭議點主要是在10kv故障的形式、消弧線圈的應用范圍、兩種運行方式供可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以纜為主的城區10kv網中性點方式的選擇問題進行研究。論文首先對10kv網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變站10kv網的實際參數來建立數值計算模型,在考慮了變化、中性點阻取值大小、阻值變化等多種影響因素的情況下,對中性點經消弧線圈和經小方式下網的過壓水平和點短路大小進行了數值計算,其計算結果與科院所作現場試驗進行了比較。
  8. Electronic co., ltd., a private hi - tech company, professionally makes and markets electronic instruments and gauges, such as digital torque tester, bottle cap torque tester, voltage resistance tester, grounding resistance tester, leakage current tester, insulation resistance tester and etc. lankers quality instruments and gauges are characterized by well - designed structure, high reliability and stability and outstanding performance and are well sold to users in the industries of home appliances, motorcycle, automobile, motor and pharmaceutical

    市藍光子有限公司是一家集科研生產銷售於一體的高科技民營企業,公司擁有雄厚的技術實力,以卓越的設計能力,完備的工藝控制和完善可靠的檢測手段,向用戶提供高性價比的子測量儀器。主要產品有:數字扭力測試儀系列瓶蓋扭力測試儀系列耐壓測試儀,阻測試儀,泄漏測試儀,絕緣阻測試儀等安規測試儀系列。
  9. The model considers peak value of lightning current, tower grounding resistance, tower style, line surge impedance, power frequency voltage and distance between towers

    模型中考慮了雷幅值、桿塔沖擊阻、桿塔具體形狀、尺寸、桿塔波阻抗、工頻壓及檔距等因素的影響。
  10. The reasearch about both function device of compensate and line selection about single - phase grounding capacitire current for small current grounding system

    系統單相補償與選線雙功能裝置的研究
  11. Small earthing neutral grouding power system

    網單相故障選線的新方法
  12. Specification of single phase earthed relay in non - effective earthed power system

    接地電流系統單相保護裝置
  13. This paper is focused on the operation of single - phase earthprotection for little earth current system. based on the analyses for several kinds of ground protections, one ground protection with the functions of line selection and ground positioning is proposed for the complex automatic and mordern management for the electric substation. by this means, the economic, reliability, safty and stable operation for the grid can be achieved

    針對小接地電流系統單相保護的運行進行了論述,並分析比較了幾種目前採用的小接地電流系統單相保護的功能及優缺點,建議採用一種既能選線又能定位的小接地電流系統單相保護裝置,以適應綜合自動化和現代化管理的需要,確保系統經濟、可靠、安全、穩定運行。
  14. Sy - kang shen, bor - chyun wang, ching - yin lee and tsung - chih lin, “ a modified qft design method for a cascaded multiple loop system and application in idle speed control ”, 1999 international symposium on quantitative feedback theory and robust frequency domain methods, pp. 25 ~ 41, university of natal, durban, south africa, august, ( 1999 )

    [ 22古碧源,李清吟,顏坤鴻,楊仲健,林春福, "二極體捷運直系統之位與雜散, "第十九屆力工程研討會論文集,第677至681頁, ( 1998 )
  15. Under the conditions of high safe coefficient of insulated electrical strength of the stator winding of the generator, the selection of earthing resistance value should meet the needs of matching one - point earthing protection of the stator and limiting the fault current

    在發機定子繞組絕緣氣強度有較高的安全系數的情況下,阻值的選取應主要服從與定子一點保護的配合及限制故障的需要。
  16. Firstly, the paper introduced the commonly hardware configure of microcomputer relaying and the function of every module of industry controlling computer std90386. secondly, the paper introduced several types busbarprotection which was commonly installed on electric power system and the characteristic of mv or lv system with low current grounding. based on it, the paper put forwards the theory of percentage - restraint differential relay. after that, in the discussing every problems of the relaying working the paper put the emphasis on the negative effect of the ct saturation and countermeasure

    本文首先介紹了微機保護裝置的一般硬體配置以及作為裝置硬體平臺的std90386工控機各組件模板的功能,然後分析了目前網系統裝設的母線保護的各種類型以及中、低壓小網的特點,在此基礎上分析、介紹了作為本保護動作原理的「比率制動式差動保護」原理。
  17. In the 3 ~ 35kv power supply system of our country, the large part is the not solidly earthed neutral system. when the single - phase earthed phenomena happens in this system, this electric power network can run with failure. and in this way the operated cost can reduce greadty. and at the same time the power supply systemic dependability can be improved. but when the single - phase earthed current is large, this electric power system can engender easily arc earthed overvoltage and interphase short circuit by this means

    在我國10 35kv供系統中,主要為中性點非直系統,這種系統在發生單相時,網仍可帶故障運行,這樣可以大大降低運行成本,提高供系統的可靠性,但這種供方式在單相較大時容易產生弧光壓和相間短路,給供設備造成了極大的危害。
  18. A kind of auto - compensation single - phase earthing current device of electric power system

    力系統單相接地電流自動補償裝置
  19. Test and control of single - phase grounding electric current in 6kv power network in mines

    網單相接地電流的測試與治理
  20. Measurement and treatment of 6kv power net single - phase earth - connecting current in coal mine

    網單相接地電流的測試與治理
分享友人