接收透鏡系統 的英文怎麼說

中文拼音 [jiēshōutòujìngtǒng]
接收透鏡系統 英文
receiving lens system
  • : Ⅰ動詞1 (靠近;接觸) come into contact with; come close to 2 (連接; 使連接) connect; join; put ...
  • : Ⅰ動詞1 (把攤開的或分散的事物聚集、合攏) put away; take in 2 (收取) collect 3 (收割) harvest...
  • : Ⅰ動詞1 (滲透; 穿透) penetrate; pass [seep] through 2 (暗地裡告訴) tell secretly; let out; lea...
  • : Ⅰ名詞1 (鏡子) looking glass; mirror 2 (幫助視力或做光學實驗的器具) lens; glass 3 (姓氏) a s...
  • : 系動詞(打結; 扣) tie; fasten; do up; button up
  • : Ⅰ名詞1 (事物間連續的關系) interconnected system 2 (衣服等的筒狀部分) any tube shaped part of ...
  • 接收 : 1 (收受) receive; reception; accept; [電學] receipt; receiving 2 (接管) take over; expropriat...
  • 透鏡 : [物理學] lens; optical lens
  • 系統 : 1. (按一定關系組成的同類事物) system 2. (有條理的;有系統的) systematic
  1. Compared with current instruments, the setup can decrease disturbance of disorder radiation by using double layer refractive index sample matching vessel, and it can increase collecting and transmitting efficiency of radiation by adopting single mode fiber with gradient refractive index lens. with a low power laser, the sample has a low scathe, and the laser and the measurement system can be integrated conveniently

    與現有的同類型儀器相比,該儀器採用雙層折射率樣品匹配池減少了雜散光的干擾;採用帶梯度折射率的單模光纖、傳輸散射光信號提高了散射光的集傳輸效率;用低強度的激光避免了對樣品的輻射損傷,同時可以使激光器和集成在一起,整個小型實用。
  2. On the base of studying imaging theory of lens, the imaging theory of laser confocal scanning microscopy was analyzed in detail in this paper, and the advancement of that the optical fiber was applied to the system was described ; on the base of completed the demonstration for whole project, the experiment scheme was designed ; the relationship between the main parameters of key devices and the resolution was deduced, and the requirements of coupling efficiency and vignetting effects to optical system was analyzed ; the design of optical system and the planar scanning controlling circuit was completed ; a new method was put forward to resolved the inherent non - liner scanning problem of the galvanometer scanner by using software liner controlling in circuit design, and the perfect planar scanning was realized ; at last the low noise, high multiple and non - distortion amplify circuit of photoelectric detector was completed

    本文在成像理論的基礎上,、深入地分析了共焦掃描顯微成像的機理,論述了應用單模光纖的激光共焦掃描顯微成像的優點;進行了總體方案的論證,並設計確定了單模光纖激光共焦掃描顯微成像的總體方案;從理論上推導分析了解析度要求與試驗中相關器件主要參數之間的關,分析了耦合效率和漸暈現象對光學的設計要求;完成了方案中光學和二維掃描控制電路的設計,並在電路設計中採用了用軟體解決檢流計式光學掃描器(振)非線性問題的新方法,能夠實現較為理想的二維模擬掃描;完成了高增益、低噪聲和低失真的探測的設計和調試。
  3. According to the principle of correlation detection, an automatic measurement system for extinction ratio of polarizer consisted of monochromator and dsp lock - in amplifier and compurer is designed not only to eliminate the influence on measurement accuracy caused by drift of intensity of light source but also to obatain approximate extinction spectrum

    摘要基於相干檢測原理設計了一套由單色儀、數字鎖相放大器和計算機聯合使用的射式偏光消光比智能化測試實驗,採用雙頻雙光路分光單探測器鎖相放大器分離信號比對法進行源補償測量,克服了光源光強漂移所帶來的影響;實現了可見光區消光比的精確自動測量,而且可以測得近似的消光光譜。
分享友人