推斷的接觸帶 的英文怎麼說
中文拼音 [tuīduàndejiēchùdài]
推斷的接觸帶
英文
inferred contact- 推 : 動詞1 (向外用力使物體移動) push; shove 2 (磨或碾) turn a mill or grindstone; grind 3 (剪或削...
- 斷 : Ⅰ動詞1 (分成段) break; snap 2 (斷絕;隔斷) break off; cut off; stop 3 (戒除) give up; abstai...
- 的 : 4次方是 The fourth power of 2 is direction
- 接 : Ⅰ動詞1 (靠近;接觸) come into contact with; come close to 2 (連接; 使連接) connect; join; put ...
- 觸 : Ⅰ動詞1 (接觸) touch; contact 2 (碰; 撞) strike; hit 3 (觸動) touch 4 (感動) move sb ; sti...
- 推斷 : infer; deduce; deduction
- 接觸 : 1. (交往) come into contact with; get in touch with 2. (沖突) engage 3. (挨上; 碰著) contact; touch
-
On - line monitoring of hvcb is the precondition of predicting maintenance, is the key element of reliable run, and is the important supplement to the traditional off - line preventive maintenance in fact, the faults are made by hvcb, no matter in number or in times, is over 60 % of total faults so it has determinative importance for improving the reliability of power supply and this can greatly decrease the capital waste used by - dating overhaul in this paper, the inspecting way of hvcb mechanism characteristic is discussed the concept of sub - circuit protector is presented, the scheme that we offered has been combined with sub - circuit integrality monitoring theory, to ensure that it has the two functions as a whole according the shut - off times at rated short circuit given by hvcb manufacturer, the electricity longevity loss can be calculated in each operation, and the remained longevity can be forecast too an indirect way for calculating main touch ' s temperature by using breaker shell temperature, air circumference temperature and breaker ' s heat resistance is improved in this paper, and main touch resistance can be calculated if providing the load current msp430, a new single chip microcomputer made by ti company, is engaged to develop the hardware system of the on - line monitoring device, and special problem brought by the lower supply voltage range of this chip is considered fully
高壓斷路器所造成的事故無論是在次數,還是在事故所造成的停電時間上都占據總量60以上。因此,及時了解斷路器的工作狀態對提高供電可靠性有決定性意義;並可以大大減少盲目定期檢修帶來的資金浪費。本文論述了斷路器機械特性參數監測方法;提出了二次迴路保護器的概念,並將跳、合閘線圈完整性監視和二次迴路保護結合起來,給出具有完整性監視功能的二次迴路保護器實現方案;根據斷路器生產廠家提供的斷路器額定短路電流分斷次數,計算每次分閘對應的觸頭電壽命損耗,預測觸頭電壽命;提出根據斷路器殼體溫度和斷路器周圍空氣溫度結合斷路器熱阻來計算斷路器主觸頭穩態溫升的方法,並根據此時的負荷電流間接計算主觸頭迴路的電阻;在硬體電路設計上,採用美國ti公司最新推出的一種功能強大的單片機msp430 ,並充分考慮該晶元的適用電壓范圍給設計帶來的特殊問題;在通信模塊的設計中,解決了不同工作電壓晶元之間的介面問題,並給出了直接聯接的接線方案。It is concluded that the thrust structure formed in late - jurassic. faults with high angles appeared in hengshanbu structure part which is also developed in late - jurassic deduced by strata contact relationship. middle district includes two parts which
橫山堡構造帶發育由東向西逆沖的高角度斷裂,根據地層接觸關系,推斷該構造帶的逆沖活動發生於晚侏羅世。( 5 ) according to the study on seismicic data, sedimentary characteristics, contact relations, incision relation of the faults and strata related to the folds which are associated with the faults, this paper reached the conclusions : the oblique - thrusting structure of sertengshan - xitieshan in northern qaidam basin was formed in middle jurassic and the left - thrusting fault zone was established in the late pliocene of neogene
( 5 )根據地震質料、沉積特徵、地層的沉積接觸關系、斷裂切割地層關系以及與斷裂相關的褶皺捲入地層的研究,認為柴達木盆地北緣的賽什騰? ?錫鐵山逆沖推覆構造形成於中侏羅世,而左行逆沖斷裂帶定型于新第三紀上新世末。
分享友人