推斷的接觸帶 的英文怎麼說

中文拼音 [tuīduàndejiēchùdài]
推斷的接觸帶 英文
inferred contact
  • : 動詞1 (向外用力使物體移動) push; shove 2 (磨或碾) turn a mill or grindstone; grind 3 (剪或削...
  • : Ⅰ動詞1 (分成段) break; snap 2 (斷絕;隔斷) break off; cut off; stop 3 (戒除) give up; abstai...
  • : 4次方是 The fourth power of 2 is direction
  • : Ⅰ動詞1 (靠近;接觸) come into contact with; come close to 2 (連接; 使連接) connect; join; put ...
  • : Ⅰ動詞1 (接觸) touch; contact 2 (碰; 撞) strike; hit 3 (觸動) touch 4 (感動) move sb ; sti...
  • 推斷 : infer; deduce; deduction
  • 接觸 : 1. (交往) come into contact with; get in touch with 2. (沖突) engage 3. (挨上; 碰著) contact; touch
  1. On - line monitoring of hvcb is the precondition of predicting maintenance, is the key element of reliable run, and is the important supplement to the traditional off - line preventive maintenance in fact, the faults are made by hvcb, no matter in number or in times, is over 60 % of total faults so it has determinative importance for improving the reliability of power supply and this can greatly decrease the capital waste used by - dating overhaul in this paper, the inspecting way of hvcb mechanism characteristic is discussed the concept of sub - circuit protector is presented, the scheme that we offered has been combined with sub - circuit integrality monitoring theory, to ensure that it has the two functions as a whole according the shut - off times at rated short circuit given by hvcb manufacturer, the electricity longevity loss can be calculated in each operation, and the remained longevity can be forecast too an indirect way for calculating main touch ' s temperature by using breaker shell temperature, air circumference temperature and breaker ' s heat resistance is improved in this paper, and main touch resistance can be calculated if providing the load current msp430, a new single chip microcomputer made by ti company, is engaged to develop the hardware system of the on - line monitoring device, and special problem brought by the lower supply voltage range of this chip is considered fully

    高壓路器所造成事故無論是在次數,還是在事故所造成停電時間上都占據總量60以上。因此,及時了解路器工作狀態對提高供電可靠性有決定性意義;並可以大大減少盲目定期檢修資金浪費。本文論述了路器機械特性參數監測方法;提出了二次迴路保護器概念,並將跳、合閘線圈完整性監視和二次迴路保護結合起來,給出具有完整性監視功能二次迴路保護器實現方案;根據路器生產廠家提供路器額定短路電流分次數,計算每次分閘對應頭電壽命損耗,預測頭電壽命;提出根據路器殼體溫度和路器周圍空氣溫度結合路器熱阻來計算路器主頭穩態溫升方法,並根據此時負荷電流間計算主頭迴路電阻;在硬體電路設計上,採用美國ti公司最新一種功能強大單片機msp430 ,並充分考慮該晶元適用電壓范圍給設計特殊問題;在通信模塊設計中,解決了不同工作電壓晶元之間介面問題,並給出了直線方案。
  2. It is concluded that the thrust structure formed in late - jurassic. faults with high angles appeared in hengshanbu structure part which is also developed in late - jurassic deduced by strata contact relationship. middle district includes two parts which

    橫山堡構造發育由東向西逆沖高角度裂,根據地層關系,該構造逆沖活動發生於晚侏羅世。
  3. ( 5 ) according to the study on seismicic data, sedimentary characteristics, contact relations, incision relation of the faults and strata related to the folds which are associated with the faults, this paper reached the conclusions : the oblique - thrusting structure of sertengshan - xitieshan in northern qaidam basin was formed in middle jurassic and the left - thrusting fault zone was established in the late pliocene of neogene

    ( 5 )根據地震質料、沉積特徵、地層沉積關系、裂切割地層關系以及與裂相關褶皺捲入地層研究,認為柴達木盆地北緣賽什騰? ?錫鐵山逆沖覆構造形成於中侏羅世,而左行逆沖定型于新第三紀上新世末。
分享友人