散流器 的英文怎麼說

中文拼音 [sǎnliú]
散流器 英文
diffuser air su ly
  • : 散動詞1. (由聚集而分離) break up; disperse 2. (散布) distribute; disseminate; give out 3. (排除) dispel; let out
  • : Ⅰ動1 (液體移動; 流動) flow 2 (移動不定) drift; move; wander 3 (流傳; 傳播) spread 4 (向壞...
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  1. Heating radiator. steel finned - tube convector

    採暖.鋼制翅片管對
  2. Radiators and convectors - part 3 : evaluation of conformity

    和換.第3部分:合格評定
  3. Specification for radiators and convectors - evaluation of conformity

    和對規范.合格評價
  4. Radiators and convectors - part 2 : test methods and rating

    和對.第2部分:試驗方法和定級
  5. Radiators and convectors. part 2 : test methods and rating

    和換.第2部分:測試方法和額定值
  6. Radiators and convectors. part 1 : technical specifications and requirements

    和換.第1部分:技術規范和要求
  7. Radiators and convectors - part 1 : technical specifications and requirements

    和對.第1部分:技術規范和要求
  8. Specification for radiators and convectors - test methods and rating

    和熱空氣循環對加熱規范.試驗方法和級別
  9. Testing methods for diffusive flow through membrane filters

    薄膜濾量的測試方法
  10. Through the research work of this article, it is shown that cfd technology can efficeintly instruct the design of indoor air distribution and evaluate indoor air quality and ventilating effect ; the distribution of heat sources have great impact on indoor air distribution ; under variable air volume condition, the indoor temperature and velocity fields are quite even and the thermo - environment is relatively good when using diffusers with coanda effect such as square diffuser and slot diffuser to supply air

    經過本文研究發現,利用cfd技術可以有效地對空調室內氣組織設計進行指導,全面對室內空氣品質和通風效果進行評價。熱源分佈對于空調室內的氣組織具有極其重大的影響。在變風量條件下,利用具有良好貼附效應的送風口如方型散流器和條縫風口送風,空調室內的溫度場和速度場較均勻,室內的熱環境良好。
  11. And contracts the temperature field by shutter air supply and diffuser air supply. above the conclusions, in some degree, have an instructive and directive significance to actual object practice

    並西安建築科技大學碩士學位論文且通過工程改進性實測,對單層百葉風口上送風和散流器送風的溫度場進行了比較。
  12. In this article, simulations of air distribution in the vav air - conditioned office are carried out in the cases of different air - supplying diffusers including slot diffuser, sqaure grille, bar grille and square diffuser to supply air, the standard three - dimensional k - ? two - equation turbulence model with correctional item of buoyancy effect and simple algorithm are adopted, and wall function method is used to handle boundary conditions

    本文採用經過浮升力項修正的-兩方程模型和simple演算法,應用壁面函數法處理邊界條件,對利用包括條縫風口、方型百葉風口、長條型百葉風口和方型散流器不同型式送風口送風的變風量空調房間內的氣組織進行了模擬。
  13. Analyses the key issues in selecting air - cooled water chillers, adopting fan coil unit and diffuser to supply air and designing of smoke extract fans

    摘要分析了風冷冷水機組選型、用風機盤管接散流器送風、排煙風機控制設計應注意的問題。
  14. The application and research of cold - air diffusers

    低溫送風散流器的應用研究
  15. Evaluation of performance of cold air distribution diffuser

    低溫送風系統散流器的性能評價
  16. In the paper, we made initial studies on whether square diffuser could be used in variables air volume in a cooling mode

    本文對方形散流器是否可用於變風量系統進行了初步研究。
  17. The proper selection of air diffusers will help to ensure that variable air volume will operate over a range of air volumes well

    送風散流器的合適選擇有助於確保變風量系統在較大的風量范圍內運行良好。
  18. Further improvements occurred once the outfall was replaced by a new one utilising more effective diffusers in 2003, at which time other enhancements to the treatment works were also made

    2003年,該廠裝置了設有強效散流器的新型排污渠,同時又改良了多項其它設施,使長洲的水質進一步改善。
  19. As air distributor in a variable air volume system, the performance of slot diffuser is the best one, but the type of diffuser is too expensive, so at home many firms try to choose square diffuser

    條縫形散流器作為變風量系統的空氣分佈其性能是最好的,但這種條縫形散流器過于昂貴,故國內許多公司選擇採用方形散流器
  20. Through thorough analysis, we finally drew that on condition of experiment, square diffuser could ensure good air distribution when air supply volumes ranged from 40 to 50 percent or 80 to 100 percent of the maximum air supply volumes. when air supply volumes ranged from 50 to 80 percent of the maximum air supply volumes, square diffuser could not be very ideal with a variable air volume in a cooling mode

    經過全面分析,最後得出主要結論:在實驗條件下,當送風量處于最大送風量的40 50或80 100范圍內時,方形散流器可滿足室內氣分佈的要求;當送風量處于最大送風量的50 80范圍內時,方形散流器用於變風量系統供冷工況不理想。
分享友人