暫時電流 的英文怎麼說

中文拼音 [zhànshídiànliú]
暫時電流 英文
contra flow
  • : Ⅰ形容詞(時間短) short; momentary Ⅱ副詞(暫時) temporarily; for the moment; for the time being
  • : shí]Ⅰ名1 (比較長的一段時間)time; times; days:當時at that time; in those days; 古時 ancient tim...
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : Ⅰ動1 (液體移動; 流動) flow 2 (移動不定) drift; move; wander 3 (流傳; 傳播) spread 4 (向壞...
  • 暫時 : temporary; transient; for the time being
  • 電流 : current; galvanic current; electric current; electricity; current flow電流保護裝置 current protec...
  1. Electric currents persisted only for a moment.

    動只持續短間。
  2. There is great change of negative current component when it happens the line - open fault. it is marked as the occurrence of the fault. and it can be concluded the phase characteristic of negative current in the line. in the transient course, there are plenty of harmonics in the fault line. through the transient analysis, it is drawed that the amplitude of each harmonic in fault phase is greater than other phases. harmonic current in fault line is far greater than other normal lines

    發生斷線故障以後,線路中會出現負序的突變,可以作為故障啟動判斷的標志,並且通過分析得出了故障負序基波的相位特點。在故障態過程中,故障中含有大量豐富的諧波成分,各次諧波在故障期間有突變,並且衰減很快。
  3. Promethean ' s disfigurements become briefly visible to mortals when the promethean spends pyros points or uses electrical current to heal wounds

    當活屍耗用聖火或使用療傷,會短地現出原貌。
  4. For the severe limitation that the selectivity of transient current protection will lose when the fault with small resistance or without resistance takes place at the end of transmission line, the basic reason for the selectivity loss of transient current protection was investigated

    摘要針對保護出口處發生金屬性或小阻短路故障保護完全失去選擇性的嚴重缺陷,利用域分析方法,進行了詳細的故障態分析和模擬研究。
  5. The hardware circuit design include : industrial control computer configuration, selection of industrial control board type, design of the power supply and monitoring interface circuit, design of signal processing interface circuit ( the constant current source circuit, the time base signal processing circuit, the processing circuit for the signal to be measured ), design of panel control circuit, design of the system self - checking circuit, and etc. the program flow hart include : main program flow chart, system boot - strap self - checking program flow chart, manual static testing program flow chart, semiautomatic static testing program flow chart, automatic static testing program flow chart, dynamic testing program flow chart, transient testing program flow chart, source voltage and current monitor program flow chart, investigate function testing program flow chart, and etc. the measure system offers six working power supplies, the signal of time base, the signal of constant current source, sine wave signal and step to leap signal, and measures the frequency of the output pulse signal of the wide range pulse convert circuit accurately under three kinds of different test state ( static form, dynamic form and transient form )

    硬體路設計包括:工控機配置、工控板卡選型、產品源及監控介面路設計、信號處理介面路(恆路、基信號處理路、被測信號處理路)設計、面板控制路設計、系統自檢路設計等。程序程圖包括:主程序程圖、系統開機自檢程序程圖、手動靜態測試程序程圖、半自動靜態測試程序程圖、自動靜態測試程序程圖、動態測試程序程圖、態測試程序程圖、壓和監控程序程圖、研究功能測試程序程圖等。測試系統提供六路工作源、基信號、恆源信號、正弦波信號和階躍信號,並對三種不同測試狀態(靜態、動態、態)下大量程脈沖變換路輸出脈沖信號的頻率進行精確測量。
  6. Because there is direct relation ship with fault currents and transient and dynamic voltages, in theory or practice, it is so complicated that the selection of generator neutral grounding model will affect or determine the generator protection scheme

    由於態過壓、接地故障等都直接與發機接地方式有關,同還影響或決定著發機的保護形式,所以接地方式的選擇在理論和實踐上都是一個復雜的問題。
  7. The contents are using fault locating algorithm based on measurement impedance to determine a fault zone of transmission line, then use wavelet transform fault locating algorithm based on current traveling wave to fix the fault position. in order to ensure both results are valid, gps is used to synchronize their hardware. 2

    其主要內容是:利用所記錄的工頻故障信息和阻抗法粗略計算故障位置,再利用所記錄的態行波精確定位故障點,二者通過gps間同步單元進行間同步,從根本上解決輸線路故障測距問題。
  8. In the experiment of testing instantaneous characteristics for circuit breaker, the transient current exists in the experimental circuit because of the closing making angle, which has serious influence on the testing precision

    斷路器進行瞬動特性試驗,由於合閘相角的原因,試驗路中會產生的存在對試驗精度產生嚴重的影響。
  9. When the voltage exceeds the breakdown strength for a given insulation system, undesirable conduction paths will be created and the system will be either temporarily or permanently disabled

    壓超過確定絕緣系統的擊穿值,將出現預料之外的路徑而且這個絕緣系統將或永久地停止作用了。
  10. According to the actuality of the present research on ct, this paper introduces the measurement principle of rogowski coil and analyzes the factor that influence the precision of measurement, we bring forward a new design scheme based on the rogowski coil

    本文首先介紹了國內外互感器發展現狀,重點對rogowski線圈測量原理進行分析,研究了線圈的穩態測量誤差以及幅頻特性、相頻特性、間響應特性,論證了羅氏線圈作為傳感器單元所具有的優良特性。
  11. By analyzing the refraction 、 reflection process of fault transient current traveling wave of high voltage and characteristics of refraction 、 reflection coefficient systematically, a new fault location method of single ended traveling wave is presented. it can not only identify the reflection wave for fault location efficiently, but also not be affected by the structure and length of line. fault earthed resistance 、 fault type 、 system impedance and can locate fault in adjacent areas accurately

    論文深入地分析了高壓線路故障行波的波折、反射過程以及折、反射系數的特點,提出了新的單端行波故障測距方法,它不僅能夠有效地識別出測距所用的反射波,而且幾乎不受線路結構、長短、故障接地阻、故障類型、系統阻抗的影響,在近區仍可以準確地進行測距;同模擬阻波器的特徵,設計了低通數字濾波器,對通過了低通數字濾波器的態故障行波再次進行小波分析,並利用本文提出的單端行波故障測距方法進行故障定位,結論是所提出的測距方法在實際應用中仍是有效的。
  12. By using high - speed data acquisitioning unit designed specially to capture travelling waves of transient current, using global positioning system ( gps ) to supply high precise time tagging for both ends, using wavelet transform theories to identify the head of the travelling waves, the fault locator can realize high precise double - ended travelling waves location

    該測距裝置採用專門設計的高速采樣單元捕獲行波信號,用全球定位系統( gps )為線路兩端提供精度高達1 s的統一標,用小波變換理論識別行波波頭信息,從而可以實現高精度的雙端行波法測距( 150m ) 。
  13. Judging by the different magnitude and direction of the wavelet packet coefficient modular maximum, we can select the single phase - to - earth line. the method using wavelet singularity detection theory to extract the fault time is discussed. a fault distance measurement algorithm combining wavelet analysis used for separating the character from the transient fault signal with artificial neural networks used for the nonlinear approximation from the transient character to fault distance is presented

    論文提出利用各個出線零序在頻帶上小波包系數模極大值的方向和大小的不同來實現故障選線,討論了利用小波分析的奇異性來判斷故障啟動刻,提出將小波分析和人工神經網路結合,利用人工神經網路的非線性逼近能力,實現故障態量到故障距離的非線性映射,完成測距。
  14. Reactive power are calculated using the new algorithm. on the basis of analyzing different kinds of control strategies of var compensation, the paper applies the criterion of voltage and var to control switching and illustrates a improved mode of switching capacitor which can prevent the switched - capacitor from the impacting of instantaneous rush currents by means of zero - crossing triggering of scr components, and can realize auto - tracking var and auto - switching shunt capacitor bank. initial operating parameters are stored in information flash memory of the mcu using flash self - programming technique in order to decrease complexity of the circuit and improve stability

    高壓智能無功補償控制器以flash型16位單片機msp430f149為控制核心,採用了一種相角實測量的新演算法,並在此基礎上計算出了功率因數、有功和無功,減少了運算量提高了精度;在分析了各種無功補償控制策略的基礎上,以母線壓和無功功率復合判據控制投切,並提出一種改進的容器投切方式? ?態投切控制晶閘管過零觸發,避免了容器投切沖擊;穩態運行接觸器替代晶閘管,實現無功補償的自動跟蹤和容器的自動投切,解決了投切沖擊和穩態可靠運行的難題;控制器的原始運行參數採用flash自編程技術,將其保存在msp430f149片內的信息flash中,簡化了硬體路,大大提高了系統的可靠性。
  15. Further, the methods are proposed to compare and summarize for choosing fault line and detecting distance in neutral ungrounded system. subsequently, the characteristics of zero sequence current and transient courses are introduced and analyzed

    接著對小接地系統單相接地故障零序態過程及特點做了介紹和分析。
  16. Since that the choosing line hardware for the neutral ungrounded system has just passed part of the dynamic simulative test, matlab software was chosen to do a lot of simulative tests on single phase - to - grounding fault. and the simulative sampling ratio is almost the same as the hardware ' s. because there is a low wave filter in the hardware, i choose the db15 wave - let to carry out the multidimensional decomposition on the sample by the method of one dimension discrete wavelet in order to obtain low frequency signal including the high frequency transient information on single phase - to - grounding fault

    鑒于實驗室已有的小接地系統選線硬體的研製只通過了實驗室里的動模試驗,故選用matlab軟體對小接地系統進行大量的單相接地故障模擬試驗,模擬的采樣率和硬體基本一致,由於硬體中帶有低通濾波器,故在進行采樣數據的morlet小波分析先採用db15小波對采樣進行一維離散小波的多尺度分解,使得分解得到的低頻信號剛好包括了小接地系統單相接地故障態高頻信息,然後對這一信息再繼續進行小波演算法分析,分析結論表明利用變換后的實部、虛部和模值能夠較準確的實現單相接地故障的故障選線和態高頻分量的提取。
  17. The transient solution obtained from the multi - loop mathematical model are in agreement with experiment results approximately under the conditions that saturation is not severe. though the errors of currents in some non - fault branch seem a little large, the fundamental components of the simulation current are accurate

    結果表明,多迴路數學模型在機飽和不嚴重的情況下,態模擬結果與實驗結果大致吻合,雖然有非故障分支與實驗結果的差異比較大,但基波分量還比較準確,基本可以滿足保護方案的靈敏度校驗等工程需要。
  18. Subsequently, the transient course and characteristics of zero sequence capacitive current are introduced and analyzed

    然後對小接地系統單相接地零序態過程及特點做了介紹和分析。
  19. Based on the tsc reactive compensation equipment, a new low - voltage intelligent controller is designed, which can slove switched - capacitor without instantaneous rush current by means of zero - crossing triggering of scr components, and can realize auto - tracking reactive power, compensating and auto - switching scb. msp430f149 mcu is used as its core controller. it is shown that the algorithm in hand has the vantage of decreasing power loss and lowers of voltage and increasing the distribution system efficiency, for example power factor

    該控制器以msp430f149為控制核心,態投切控制晶閘管過零觸發,避免了容器投切沖擊;穩態運行接觸器替代晶閘管,實現了無功補償的自動跟蹤和容器的自動投切,解決了投切沖擊和穩態可靠運行的難題。
  20. The transient analysis and simulation studies in time - domain showed that the transient capacitance current of busbar is unable to be caught due to the limitation of the given sampling frequency, therefore the transient current singularity of the fault line and the non - fault line will approximate, which prevents to identify the fault line with the criterion calculation result of transient current protection

    研究結果表明,線路出口故障保護完全失去選擇性的根本原因是,在給定的采樣頻率的限制下,難以捕捉到過渡過程中極其短的母線分佈容中的,從而故障線路與非故障線路波形的奇異性相近,根據故障線路和非故障線路的態保護判據計算結果不能正確識別故障線路。
分享友人