校正脈沖 的英文怎麼說

中文拼音 [jiàozhēngmàichōng]
校正脈沖 英文
correcting pulse
  • : 校名詞1. (學校) school 2. (校官) field officer3. (姓氏) a surname
  • : 正名詞(正月) the first month of the lunar year; the first moon
  • : 脈名詞1. (動脈和靜脈的統稱) arteries and veins2. (脈搏的簡稱) pulse 3. (像血管的組織; 連貫成系統的東西) vein
  • 校正 : check; correction; adjust; revise; proofread and correct; rectify; calibrate; make true; master c...
  1. This paper starts the research of the liquid floated pendulous accelerometer testing system according to the engineering. at first, this paper gives the brief introduction of the history and present status of accelerometer and its testing technology, the working principium and math model of the liquid floated pendu - lous accelerometer, and then, decides the binary width pulse force retrim loop as the design proposal of testing system, researches the transfer function of every part in the system emphasizly, analyses the stability of the whole accelerometer testing system from the angle of control theoretics by the open loop transfer function of system, and designed the correcting net, analyses the basal problems such as resolution, sampling restraint, precision and so on, designs the hardware testing circuits such as preamplification, band - pass filter, alternating amplifier, phase sensitive demodulatorn, pulse - width modulation, frequency scale circuit, moment current generator. finally, using the graphics program language labv - iew which is designed for testing field especially by ni accomplishes the solfware design of testing system, realized the testing functions

    首先對加速度計及其測試技術的發展歷史和現狀,液浮擺式加速度計的工作原理和數學模型等作了簡要的介紹,然後確定了以二元調寬再平衡測試迴路為設計方案,並從控制理論的角度進行了分析,著重研究了系統中各部分的傳遞函數,利用系統開環傳遞函數分析了系統的穩定性,同時設計了系統的網路;分析了二元調寬再平衡測試迴路的解析度、采樣約束以及測試精度等基本問題,並按照系統分析的結果設計了包括前置放大、帶通濾波、交流放大、相敏解調、寬調制、頻標電路以及力矩電流發生器等測試系統各部分硬體電路,驗證了電路的確性,最後按照測試系統的要求,採用了美國ni公司專為測試領域所開發的虛擬儀器工具? ? labview作為測試軟體開發工具,利用該圖形化編程語言完成了測試系統軟體部分的設計,實現了測試功能。
  2. The spectrum evolution of the femtosecond laser pulse in a three - level organic molecular medium ( 4, 4 ' - bis ( dimethylamino ) stilbene ) is studied theoretically by solving the maxwell - bloch equations using an iterative predictor - corrector finite - difference time - domain method

    摘要通過採用預估的時域有限差分法求解麥克斯韋布洛赫方程,我們研究了飛秒激光在三能級有機分子( 4 , 4 ' -二甲氨基二苯乙烯分子)介質中傳播時的頻譜演化情況。
  3. The standard suspensions to be used for the calibration are run in order, and median pulse voltages for each are determined

    依照進行的標準粒子的順序依次得出相應的中值電壓。
  4. The calibrating technology is mainly divided into two groups : the off - line ones and the on - line ones. the former one is now widely used in the monopulse system to calibrate the amplitude and phase imbalances between the sum and difference channels by injecting test signals

    離線的方法是現階段單雷達系統進行和差通道幅相採用的主要方法,它通過注入測試信號的方法來得到對誤差接收通道幅相特性的估計。
  5. Firstly, the principle of high resolution sar and theoretical imaging model were concisely introduced. pulse compression for line frequency modulation pulse signal, resolution of range direction and azimuth direction, and doppler history were discussed subsequently. in accordance with sar signal processing, range immigration was also involved

    本文首先分析了合成孔徑雷達高分辯力成像機理和sar成像理論模型,討論了線性調頻信號的匹配濾波(壓縮) 、 sar距離特性、方位特性和多普勒歷史,同時針對sar成像信號處理,分析了成像處理的基本原理和成像處理中的距離遷移等關鍵問題。
  6. When pulse width is long enough to above 2. 5ms, the corrected direction of laser hammering is away from the laser head, which may be the reason for weld bath being fatal destroyed

    寬度超過2 . 5ms時,由於熔池發生了復雜的變化,有可能使激光錘方向相反從而難以預測。
  7. The experience results indicated the reliability of this kind of thermostatic control system. the analysis and compare about modern dielectric loss measuring methods are presented on chapter 3, and the zero - crossing testing phase discrimination method is adapted as the measuring method of this measuring system. furthermore, applied high frequency pulse technique, channel self - correction technique, anti - harmonic technique are used to increase accuracy and reliability of measurement

    本文對現代介質損耗測量技術進行了分析與比較,採用過零鑒相比較法作為介質損耗測量方法,並結合外施高頻技術、通道自技術、抗諧波技術,設計了高精度介質損耗測量電路,有效提高了介質損耗測量的精度,減小了測量誤差。
  8. Electronic method ? using a multichannel peak height analyzer determine the center channel of the particle counter pulse response for each standard suspension

    電子?使用多通道峰高分析儀,測量出每種標準粒子的粒子計數器響應的中心通道。
分享友人