校準基準 的英文怎麼說

中文拼音 [jiàozhǔnzhǔn]
校準基準 英文
calibration reference
  • : 校名詞1. (學校) school 2. (校官) field officer3. (姓氏) a surname
  • : Ⅰ名詞1 (標準) standard; guideline; criterion; norm 2 (目標) aim; target Ⅱ動詞1 (依據; 依照)...
  1. Calibration specification for base circle pitch comparator

    圓齒距比較儀規范
  2. The assembly language program collects and processes the data real time. comparing kinds of method of filter and arithmetic of fft, the author select the fir filter to realize pretreatment of signal and radix - 2 fft to distill the characters of librations

    通過對各種濾波方法和fft演算法進行比較,本套數據檢測和處理系統採用fir濾波對採集到的信號進行預處理,利用2fft演算法來提取信號的頻率特徵。
  3. Basing on the analysis about the reason that how the superabundant torque appears, direct torque control strategy is used to realize the servo control of two asynchronous motors and load system ' s simulation. the measure method of superabundant torque of the system, the valid method of static state torque and the benchmark of dynamic torque are given by testifying the system ' s speediness through experiments

    在具體分析加載系統中多餘力產生原因的礎上,採用直接轉矩控制策略,實現了兩臺異步電動機伺服控制和加載系統的負載模擬實驗,通過實驗驗證了系統的快速性;給出了系統多餘轉動慣量的測量、靜態轉矩的驗和動態轉矩的實驗的本方案。
  4. All scales used must be calibrated on a regular, defined basis to a traceable international standard

    使用的計量必須依照國際標進行
  5. Acoustics - reference zero for the calibration of audiometric equipment - reference equivalent threshold sound pressure levels for pure tones and circumaural earphones

    聲學.正聽力設備的零級.純音和環繞耳機的等效閾聲壓級
  6. Acoustics - reference zero for the calibration of audiometric equipment - part 8 : reference equivalent threshold sound pressure levels for pure tones and circumaural earphones

    聲學.正聽力設備的零級.第8部分:純音和環繞耳機的等效閾聲壓級
  7. Acoustics - reference zero for the calibration of audiometric equipment - part 8 : reference equivalent threshold sound pressure levels for pure tones and circumaural earphones iso 389 - 8 : 2004 ; german version en iso 389 - 8 : 2004

    聲學.聽力設備的零級.第8部分:純音和環繞式
  8. The wave - equation - datuming ( wed ) technique is a necessary alternative to the conventional static corrections when the surface - consistent assumption is invalid

    摘要波動方程正處理被認為是當地表高程變化劇烈、地表一致性假設又不成立的情況下對于常規高程正的必要替代。
  9. According to characteristics of the seismic data from the low snr region with complex surface, this paper is started from solving the static correction problem and reasonable eliminating all kinds of disturbance in the seismic data from the low snr region with complex surface. through the whole process of seismic data processing which includes a series of processing methods that are suitable for the low snr region, namely, from the choosing of the floating base - level, the static correction in the field and indoors, the eliminating of all kinds of noise before and after stacking, the velocity analysis with high - resolution, the reasonable techniques of deconvolution before stacking and wavelet processing after stacking, to the method choosing of the high - resolution stacking and the reasonable and accurate offset imaging, a set of the complete and effective flow for processing seismic data from the low snr region with complex surface are finally formed, which can meet the need of explo

    本文針對復雜地表低信噪比地區地震資料的特點,以解決復雜地表低信噪比地區地震資料靜正問題及合理剔除各類干擾為出發點,在整個地震資料處理過程中,從浮動面的選取、野外及室內靜正、疊前疊后各類噪音的去除、高精度速度分析、合理的疊前反褶積及疊后子波處理技術、到選用高精度的疊加技術及合理確的偏移成像方法等一系列適合於復雜地表低信噪比地區的處理方法,最終形成一套較完整且有效的針對復雜地表低信噪比地區地震資料的處理流程。
  10. The principle and the mechanical structure of the air - gap inductance - type transducer are analyzed in this article, and the static parameters are calibrated. dynamic calibration is applied to air - gap inductance - type transducer which is not good in dynamic capability, to obtain the dynamic parameters of the transducer and its measuring circuit. based on the result of the dynamic calibration, the transducer and its serving circuit are modeled so that the method of how to improve the dynamic performance can be found

    本文對現有氣隙式電感傳感器在原理和機械結構上作了深入的分析,對其參數進行了靜態標定;並且針對常規電感傳感器動態響應低,不宜用於快速動態測量的缺點,引入測試系統動力學的思想,設計了一套動態系統,對現有傳感器進行多次動態,根據動態的實驗結果對現有傳感器建立數學模型,得到現有傳感器的動態特性;在此礎上,根據磨床工件在線檢測的要求,設計一個硬體補償系統來提高整個測試系統的動態特性。
  11. Gps is a planet wireless conductance system which is global and all - weather, gps can offer high precision time orientation information to infinite user, clock precision reachs 10 ? 6 magnitude 。 not only changes traditional time method of quartz crystal clock, but also replaces wireless shortwave and even more lowfrequency signal and tv signal whose overlay range is limited and low precision, offers advantage to geology field task, achieve automatization and high precision of seismic flow observation

    利用gps授時信號全方位、全天候、連續性、實時性和高精度的特點,以gps信號為本地時鐘(晶體振蕩時鐘或原子鐘) ,將gps接收機輸出信號的長期穩定度和恆溫晶振的短期穩定度相結合,應用大規模可編程邏輯器件,設計和實現了由pc104控制的實時在線授時系統。
  12. Horology. corrected cycloidal toothing gears. step up gears. basic profiles. driving gear and driven gear

    鐘表業.式擺線齒輪.增速齒輪.本型面.主動輪和從動輪
  13. Finally, the polarimetric calibration methods based on echo data and image data are proposed, and computer simulations validate the methods

    最後分別提出了於回波域和二維波數域的極化方法,模擬結果驗證了該方法的有效性。
  14. Standard test method for calibration of pyrheliometers by comparison to reference pyrheliometers

    日射強度計與日射強度計進行比較的標試驗方法
  15. Depths below datum are calculated from the corrected reflection times.

    面以下的深度,需要根據作過正的反射波時間來計算。
  16. In view of predecessors " research achievements we put forward a method using square wave excitation and the fast furrier transformation ( fft ) to realize the comparison calibration for the calibration system of piezoelectric accelerometer

    在吸收前人研究成果的礎上,文中提出了工作用壓電加速度傳感器系統應用方波信號激勵,同時應用快速傅立葉變換( fft )的方法來實現比較法
  17. A method has been developed to calibrate the positions of the transducer and the transponder in the ultra - short baseline acoustic position system ( usbl )

    摘要提出了超短線水聲定位系統( usbl )的方法,並用模擬數據進行了驗證。
  18. Checks needed to maintain confidence in the calibration status of reference, primary, transfer or working standards and reference materials shall be carried out according to defined procedures and schedules

    應根據規定的程序和日程對參考標、傳遞或工作以及參考物質進行核查,以保持其狀態的置信度
  19. Acoustics - reference zero for the calibration of audiometric equipment - reference equivalent threshold sound pressure levels for pure tones and supra - aural earphones

    聲學.音響設備零點.純音和超聽覺耳機用等效閾值聲壓級
  20. Reference neutron radiations - part 2 : calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field

    參考中子輻射.第2部分:與輻射場本參數特性有關的輻射防護裝置的
分享友人