棱性差 的英文怎麼說

中文拼音 [léngxìngchā]
棱性差 英文
prismatic error
  • : 棱名1. (物體上不同方向的兩個平面接連的部分) arris; edge; corner 2. (物體上一條一條的凸起部分) corrugation;ridge;raised angle
  • : Ⅰ名詞1 (性格) nature; character; disposition 2 (性能; 性質) property; quality 3 (性別) sex ...
  • : 差Ⅰ名詞1 (不相同; 不相合) difference; dissimilarity 2 (差錯) mistake 3 [數學] (差數) differ...
  1. But in 3d space, the sibson coordinate value is the ratio between the volumes of voronoi cells, and the voronoi cell is made up of the perpendicular face

    但推廣到三維空間中, sibson局部坐標值變為voronoi單元的體積之比,而且voronoi單元由三角劃分得到的四面體的中垂面生成, voronoi單元由面變成體,直觀,計算也變得相當復雜。
  2. This paper designs an optical system based on above to measure the small angle of the laser beam. a non - polarized beam splitter ( npbs ) is used to split the incident beam into two branches, and a rhombic prism agglutinated by two right - angle prisms is placed to realize total internal reflection twice in each branch. it not only improves the measurement sensitivity and linearity, but also increases antinoise ability by the differential optics

    本文正是基於這一原理設計了測量光束微小偏轉角的光路系統,用消偏振分光鏡將入射光分為兩路,並在兩路分別用兩個直角鏡組成的斜方鏡來實現兩次全內反射,不但提高了測量靈敏度和線,還利用分光路的特點提高了抗干擾能力。
  3. In this dissertation, we studied the tcra1101plus total station position system, which introduced the principle and characters of the instrument ' s closed loop tracking system. also we explained the cause of prism ' s position error and brought forward mathematic model to correct, moreover, the good results has been drawn form the expenriments. the kinetic survey system have been realized, which the sampling rate attain more than 5hz and the position precision can be less than 2mm on condition that targeted - point moving slowly at the velocity below 2cm / s. having finished the survey system to examine whether the fine - tuning stewart platform in good status, we have finished mensurating the position reference of the fine - tuning stewart platform and the offset of the prism

    在此基礎上研製了多臺儀器在線控制高頻采樣動態跟蹤測量系統,采樣率大於5hz ,在跟蹤小於2cm / s低速運動目標時,測量精度好於2mm ;完成對饋源二次精調系統的檢測,包括對二次精調平臺位置基準的標定和觀測鏡偏心的測定;設計不同動態測量實驗,對全站儀動態跟蹤的誤來源和特點進行了分析;從實驗角度,對全站儀的測量時滯及其穩定進行了測試分析,給出了定量的結果;比較了全站儀和計算機的內部時間系統,發現兩者存在較大異。
  4. The analyse of theary about effect on angular error for reflective characterisitic of move angular cone prism

    角度誤影響運動角錐鏡反射特的理論分析
  5. Only the main transmitted light from the glued layer or the first - order transmitted light also, is considered at most in the existing study outcome about light intensity transmission. on occasion, some experimental results about light transmission are given as a performance index. and nearly no one considers the contribution of the higher - order transmitted lights and the effects of the inaccuracy in glue technology on light distribution

    人們對它的研究,往往只考慮鏡膠合層的兩切割斜面上的主透射光束,至多同時考慮次級透射光束對出射光強的影響,或直接將光束光強透射比的實驗值的平均結果作為鏡的一個能指標給出,很少考慮鏡膠合層間光束的多次反射對輸出光強的影響以及結構誤和使用調整誤鏡光強分佈的影響。
  6. We also derive the expression of the signal obtained from random position by the magnetic field sensor. then we construct five - dimension nonlinear equation group for the signal obtained by the magnetic field sensor and solve them, so that we can realize 3d localizing and navigation for endoscope probe

    我們根據電磁場理論推導出位於正四面體六條上的分磁偶極子在空間任意點的場強表達式及探頭感應磁場信號的原理,然後建立起五元非線方程組進行定位求解。
  7. Plastic strain first starts from ambient of the porphyroblast, and then develops to rims of porphyroblast and gradually transfers to the centers of porphyroblasts. the brittle remains in the central parts of porphyroblasts come to be decreased through the plastic deformation development, which is accordance with the banding of intensity in many mylonitization zones on wild occurrences and observation in the fabrics of mylonitization rocks under microscope

    長石眼球構造的形成主要是由長石與石英的韌決定的,塑變形首先從斑晶的周圍部分開始,逐漸向斑晶發展,脆殘斑核不斷減小,這與剪切帶內糜巖化強度分帶相一致。
分享友人