棱鏡角差誤 的英文怎麼說

中文拼音 [léngjìngjiǎochā]
棱鏡角差誤 英文
prism-angle error
  • : 棱名1. (物體上不同方向的兩個平面接連的部分) arris; edge; corner 2. (物體上一條一條的凸起部分) corrugation;ridge;raised angle
  • : Ⅰ名詞1 (鏡子) looking glass; mirror 2 (幫助視力或做光學實驗的器具) lens; glass 3 (姓氏) a s...
  • : 角Ⅰ名詞1 (牛、羊、 鹿等頭上長出的堅硬的東西) horn 2 (古時軍中吹的樂器) bugle; horn 3 (形狀像...
  • : 差Ⅰ名詞1 (不相同; 不相合) difference; dissimilarity 2 (差錯) mistake 3 [數學] (差數) differ...
  • : Ⅰ名詞(錯誤) mistake; error Ⅱ動詞1 (弄錯) mistake; misunderstand 2 (耽誤) miss 3 (使受損害...
  1. This paper analyses the critical angle method that often use in focus detected. we receive two relations, the first relation between refractive index of the critical - angle prism and focus - error signal ; the second relation between numerical aperture of object lens and out - of - focus error signal

    本文針對伺服系統中常用的調焦方法-臨界方法進行了分析,理論上得到臨界的折射率、物的數值孔徑與離焦信號的關系。
  2. This paper analyses emphatically the position error and manufacture error of critical - angle prism the position error and aberration of object lens the position error and manufacture error of the polarization beam splitter the position error of the detector, and come out their relations

    著重分析了臨界位置與製造;物的位置與像;偏振分束的位置與製造;探測器的位置等對離焦信號的影響,並給出了理論曲線。
  3. In this dissertation, we studied the tcra1101plus total station position system, which introduced the principle and characters of the instrument ' s closed loop tracking system. also we explained the cause of prism ' s position error and brought forward mathematic model to correct, moreover, the good results has been drawn form the expenriments. the kinetic survey system have been realized, which the sampling rate attain more than 5hz and the position precision can be less than 2mm on condition that targeted - point moving slowly at the velocity below 2cm / s. having finished the survey system to examine whether the fine - tuning stewart platform in good status, we have finished mensurating the position reference of the fine - tuning stewart platform and the offset of the prism

    在此基礎上研製了多臺儀器在線控制高頻采樣動態跟蹤測量系統,采樣率大於5hz ,在跟蹤小於2cm / s低速運動目標時,測量精度好於2mm ;完成對饋源二次精調系統的檢測,包括對二次精調平臺位置基準的標定和觀測偏心的測定;設計不同動態測量實驗,對全站儀動態跟蹤的來源和特點進行了分析;從實驗度,對全站儀的測量時滯及其穩定性進行了測試分析,給出了定量的結果;比較了全站儀和計算機的內部時間系統,發現兩者存在較大異。
  4. The analyse of theary about effect on angular error for reflective characterisitic of move angular cone prism

    影響運動反射特性的理論分析
  5. We simulate the practicality system to experimentalize, obtain the relation between defocus and focus error signal, make it a condition that na = 0. 625 and n = 1. 7979

    並模擬實際系統,實驗得出當臨界的折射率n = 1 . 7979 、物的數值孔徑na = 0 . 625時,離焦量與離焦信號的關系曲線。
  6. Influence of beam turning error of pentagonal prism on wavefront measurement

    的光束轉向對波前測量的影響
分享友人