極限靜抗力 的英文怎麼說

中文拼音 [xiànjìngkàng]
極限靜抗力 英文
ultimate static resistance
  • : i 名詞1 (頂點; 盡頭) the utmost point; extreme 2 (地球的南北兩端; 磁體的兩端; 電源或電器上電流...
  • : Ⅰ名詞(指定的范圍; 限度) limit; bounds Ⅱ動詞(指定范圍, 不許超過) set a limit; limit; restrict
  • : Ⅰ形容詞1. (安定不動; 平靜) still; calm; motionless 2. (沒有聲響; 清靜) silent; quiet Ⅱ名詞(姓氏) a surname
  • : Ⅰ動詞1 (抵抗; 抵擋) resist; combat; fight 2 (拒絕; 抗拒) refuse; defy 3 (對等) contend with...
  • : Ⅰ名1 (力量; 能力) power; strength; ability; capacity 2 [物理學] (改變物體運動狀態的作用) forc...
  • 極限 : 1 (最高的限度) the limit; the maximum; the ultimate limit; limitation; extremity; tipping point...
  1. The corbel ' s dimension should be ascertained as the manipulative condition of diagonal section. the amount of longitudinal reinforcement be ascertained on the basis of the flexure model, is obtained according to static for balance condition, the calculative expression of the load is obtained. and in terms of the design method in ultimate state the maximum load

    我國規范對于牛腿的設計規定,牛腿尺寸的確定以斜截面裂作為控制條件,縱筋用量的確定以彎壓破壞模型為基礎,根據平衡條件得到承載的計算公式,按照狀態設計方法計算得到,箍筋用量則按照構造要求確定。
  2. Based on extensive investigation of construction technique history of chinese ancient buildings, the structure method, structure developing history and seismic behavior of chinese ancient timber structure buildings are analyzed in several respects of the structural system and form. through a series of experiments on constituent parts of chinese ancient timber building structure, including the tests on the corbels and brackets called dougong subjected to low cyclic reversed loadings, the tests on the wooden frame using the tenon - mortise joints as connections of column and beam subjected to low cyclic reversed loadings, the tests on vibration isolation effect of friction and slippage between column footing and their socle base, and a series of shaking table tests on a chinese ancient timber structure palace building mode under artificial earthquake at serving conditions, destroyed conditions and reinforced conditions, many valuable results of structures such as moment - curvature hysteretic loops of dougong structure and tenon - mortise joints under low cyckc reversed loadings, the static function, the seismic performance, energy dissipation, vibration reduction, energy - loss mechanism, nechanicalmode and failure mode were studied. aplenty of valuable parameters of the structure system were obtained, such as the natural period of structure, vibration modes, damping ratio, factor of vibration isolation, oscillate amplitude of ineitial accebration, velocity and displacement, magnitude of slippage, and the mechanism of structure failure and collapse etc. based on these research, the complete analysis of ancient timber structure under earthquake were carried out in which including mechanism analysis method, calculating mode, strength analysis of members and joints, strengthening methods for serving damaged ancient timber structure buildings were also taken into account

    依照宋代《營造法式》建造了抬梁式殿堂木結構構件及結構模型,對中國古代木結構中的典型構造如:柱腳在礎石頂面平擱簡支、柱架榫卯連接、柱高不越間之廣、側腳、生起、斗拱等的構造機理及結構功能進行了量化分析和實驗研究: (一)通過木柱石礎摩擦試驗,測定了柱腳與石礎古鏡面間的摩擦系數及摩擦隨上部結構荷載變化的規律; (二)通過單柱承載試驗,測定了古建築中木柱的受變形特徵、破壞模式、及模型材料的變形模量、承載變形等參量; (三)通過柱架低周反復荷載試驗,測定了柱架的側移剛度、柱架恢復特性及滯回曲線、榫卯張角剛度及其變化規律、柱架及榫卯的承載變形、及榫卯減振參數; (四)通過斗?低周反復荷載試驗和受壓試驗,測定了古建築木構件與木構件間摩擦系數,斗?側移剛度,斗?恢復特性及滯回曲線,斗?承載及受變形規律; (五)通過抬梁式殿堂間架模型振動臺試驗,測定了殿堂木構架結構自振周期,地震反應振形、阻尼特性及阻尼比;按結構分層特點對柱腳、柱頭和斗?層上的屋蓋的地震反應採用多點同步測量,對柱根滑移、榫卯變形、斗?的變形、復位、耗能減振參數等進行了定量分析。
  3. Based on the pseudo - static experimental results of nine abnormal joints, the damage process of abnormal joint is divided into four stages of original crack, entire crack, ultimate state and failure, the effect of axial force ratio, stirrup ratio and height of column section on seismic behavior of abnormal joint are discussed, the conclusion that anti - shear capacity of abnormal joint are studied in entire crack state by studying the minor core of abnormal joint is made, the calculating formula for anti - shear capacity of abnormal joint is proposed with a view to asymmetry in stirrup yield

    摘要根據9個鋼筋混凝土框架異型節點試件的擬試驗結果,指出異型節點受過程分為初裂、通裂、和破壞4個階段;討論了軸壓比、節點核芯配箍率、柱截面高度變化對異型節點剪性能的影響;提出應考慮節點核芯區箍筋屈服的不均勻性並在通裂狀態下以「小核芯」為分析單元來研究此類節點剪承載的建議;最終給出了異型節點剪承載的計算公式。
分享友人