氣管內管 的英文怎麼說

中文拼音 [guǎnnèiguǎn]
氣管內管 英文
endotracheal tube
  • : Ⅰ名詞1 (氣體) gas 2 (空氣) air 3 (氣息) breath 4 (自然界冷熱陰晴等現象) weather 5 (氣味...
  • : Ⅰ名詞1 (管子) pipe; tube 2 (吹奏的樂器) wind musical instrument 3 (形狀似管的電器件) valve;...
  • : 名詞1. (內部; 里頭; 里邊) inner; inside; within 2. (妻子或妻子的親屬) one's wife or her relatives 3. (姓氏) a surname
  • 氣管 : air tube; windpipe; trachea; weasand; tracheal sac氣管病 tracheopathy; tracheopathia; 氣管切開術 ...
  1. The combination of a foreign body and endobronchial actinomycosis is exceedingly rare in reviews

    異物吸入並發支放線菌感染在文獻回顧上更是非常少見。
  2. Endobronchial actinomycosis is a rare condition and may mimic a neoplasm, tuberculosis, or pneumonia

    摘要支放線菌感染是一罕見的疾病,臨床上可能被誤診為腫瘤,肺結核或肺炎。
  3. Here is an aspergillus fungus ball in a dilated bronchus

    可見擴張支的麴黴菌真菌球。
  4. Sections of the lungs at this stage would show larvae in the bronchioles.

    這時候肺部切片可顯示細支有蛔蚴。
  5. The division of cardiothoracic surgery of the department of surgery at the chinese university of hong kong is among the first in the world ( and certainly first in asia ) to investigate a new device called the endobronchial valve ( ebv ) that can be placed through a bronchoscope into the segmental airway leading to the most emphysematous lung

    香港中文大學外科學繫心胸外科組為世界上率先進行支單向活瓣( endobronchialvalve )裝置臨床研究的幾家機構之一,亦是亞洲最先引進這一技術的醫學中心。
  6. Endotracheal tube dislodgment in intensive care units

    加護病房氣管內管滑脫率
  7. What is the effect of head position changes on the depth of an endotracheal tube

    頭部位置的變化對深度有何影響?請詳細描述。
  8. Kinking of endotracheal tube ( ett ) is not an infrequent problem during general anesthesia

    摘要在全身麻醉插病患中,氣管內管彎折其實是常見的問題。
  9. Lung : hyperaemia ; extravasations ; in parabronchi and some air sacs oedematous fluids ; cannot see feed particles and in some blood vessels are the same type of fluids ( thrombi ) ; masses of bacteria in the tissue

    肺臟:充血;外滲;副支及某些肺泡有積水,沒有飼料微粒,某些血有相同的積水(血栓癥) ,有大量細菌在組織
  10. This allows anesthesia to be induced within 30 seconds and the trachea to be intubated within 60 - 90 seconds

    這樣能在30秒鐘誘導麻醉, 60 90秒鐘
  11. The kink might result from over - bending of the softening tube in the oral cavity due to oral temperature and neck flexion

    造成氣管內管彎折的可能原因是因為頸部屈曲及口腔溫度較氣管內管高以致子變軟所導致的過度彎曲。
  12. In practice the medical professional first links the resuscitation bag to the patient ' s intubation or tracheostomy, then squeezes the resuscitation bag, using both hands, in a slow motion to provide a slow inspiration speed, accompanied by mid - term intermissions, after which the resuscitation bag is suddenly released

    實際作法是醫護人員將蘇醒球連接在病人的切口或氣管內管的介面上,然後用手慢速擠壓蘇醒球,緩慢的吸速度及中期暫止,再將蘇醒球快速的放開。
  13. The premature infants in the study group had prompt and sustained improvement in oxygenation

    每公斤體重給予100毫克( 4毫升)的表面張力素,經由氣管內管分成4等份,均勻地給予。
  14. We report a case that a pvc ett wrapped with aluminum foil ignited during co2 laser surgery of the larynx

    我們要報告一位在喉部手術使用二化碳雷霆岸地,包覆鋁箔紙的氣管內管被雷射光束打中,而引發子起火燃燒的個案。
  15. Endotracheal tube ( ett ) fire is a catastrophic disaster that may occur during laser surgery of the upper airway

    摘要二氧化碳雷射應用在上呼吸道部位的手術時,造成氣管內管起火燃劃極嚴重的一個並發癥。
  16. We describe a case of unexpected kinking of ett intraorally while craniotomy was underway

    在此,我們描述一例在開顱手術進行中,氣管內管在口腔非預期彎折的病例。
  17. Early detection and immediate management of the ett kinking may reduce the possibility of morbidity andmortality in anesthesia

    所以,早期偵測及積極處理氣管內管彎折可以降低麻醉致病及死亡的可能性。
  18. Several means are available for protection of polyvinyl chloride ( pvc ) tube from fire, but they are not perfect in prevention of tires caused by laser beam

    雖然有很多防護措施可以用來保護氣管內管,但總是無法提供非常完全的保護。
  19. Besides, the flexometallic ( fm ) or armoured endotracheal tubes may be good substitutes for the polyvinyl chloride ( pvc ) ones in preventing the ett kinking during general anesthesia

    此外,含鐵絲且有彈性之氣管內管可以取代聚氯乙醯子作為預防氣管內管彎折之代替品。
  20. In this report, we emphasize the shaft of the pvc tube must be completely wrapped with aluminum foil to prevent exposure of any surface if it is used in co2 laser surgery of the upper aero digestive tract

    在這篇報告中,我們要強調的是,在應用二氧化碳雷射旅行上呼吸道部位的手術時,若呂氏包覆聚氯乙烯制的氣管內管,應將子包覆完全,而不要有任何壁裸露出來,以防被雷射光束打中。
分享友人