氣體測定器 的英文怎麼說
中文拼音 [qìtǐcèdìngqì]
氣體測定器
英文
apparatus for determination of gas- 氣 : Ⅰ名詞1 (氣體) gas 2 (空氣) air 3 (氣息) breath 4 (自然界冷熱陰晴等現象) weather 5 (氣味...
- 體 : 體構詞成分。
- 測 : 動詞1. (測量) survey; fathom; measure 2. (測度; 推測) conjecture; infer
- 定 : Ⅰ形容詞1 (平靜; 穩定) calm; stable 2 (已經確定的; 不改變的) fixed; settled; established Ⅱ動詞...
- 器 : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
- 氣體 : gas; gaseous fluid
- 測定 : determine; determination; setting-out; admeasurement; assignment; assay; finding
-
This paper deriving the theory work inflection point in the static stage characteristics curve of small measurement range linear dimension measurement. by the way of high pressure and back pressure pneumatic measure and designed the parameter of the mainly and measure spray head, which are the key component in the spray head - baffle pneumatic sensor. the different groups for the main - spray head and the measure spray head, will effect the dynamic and static stage characteristic parameter. the author have done contrast experiment and optimization design to test and verify the theory derivation whereby made the rang of show valve of pneumatic measure system measure range up to 40 u m, the sensitivity up to 100mv / u m, resolution up to 0. 05 p m, the uncertainly of measure is less than 0. o2 u m, satisfaction of requirement of groups the carboy hatch thickness size precise measure of soft shims
對高壓背壓式氣動測量用於小量程線性尺寸測量的靜態特性曲線的理論工作拐點進行了推導,對氣動測量系統中的噴嘴-擋板型氣動傳感器中的關鍵部件? ?主噴嘴和測量噴嘴的參數進行了理論設計,對主噴嘴和測量噴嘴的不同組合,將影響測量系統靜、動態特性指標的噴嘴參數進行了對比實驗和優化設計,並通過實驗驗證了理論推導,從而使氣動測量系統量程的示值范圍達到40 m ,靈敏度達到100mv m ,解析度達到0 . 05 m ,測量不確定度小於0 . 2 m ,滿足了壓縮機缸蓋軟體墊片厚度尺寸精密測量分組的要求。Other common devicesintravenous medication pumps allow the nursing staff to titrate medications ; foley catheters and urine collection bags aid in monitoring urine output ; sequential compression devices squeeze the lower extremities and reduce the incidence of deep venous thrombosis ; transvenous pacemakers stimulate the patient ' s heart to beat ; dialysis machines remove fluid and correct electrolyte and acid - base disturbances ; intraaortic balloon pumps assist the heart ' s contractility ; and neurologic monitoring systems measure intracranial pressure
其他常用裝置靜脈內給藥泵由普通護士用於滴定藥物;弗利氏導管和集尿袋幫助監測排尿量;連續壓迫裝置擠壓下肢,減少深部靜脈血栓形成;經靜脈起搏器刺激病人心臟跳動;透析儀除去液體,糾正電解質和酸堿紊亂;主動脈內氣囊泵支持心臟收縮;神經病學監測系統測定顱內壓。Laboratory glassware ; volumetric glassware for gas analysis, gas burettes, azotometers, eudiometers, nitrometers
實驗室玻璃器具.氣體分析用容量測定玻璃器具.氣體量Auto fatness measuring system, fat measure, hearing aid. gas pressure gauge of measure, digital woman thermometer, electronic infrared high - power massager, eye massager, suction unit, refractor, film box. diagnostic set, head mirror. magnetic acupuncture suction cup
全自動身高體重計、體脂肪測定器、助聽器、氧氣流量表、電子體溫計、電子婦女基礎體溫計、紅外線電動按摩器、眼部按摩器、吸引機、視力檢查器、看片箱、喉頭鏡、檢耳鏡、額頭反射鏡、哈慈五行針According to finite element segmentation principle, by combining test with observation, the author has measured the air streamline and speed distribution of burning equipment in dally situation, which provides some guide for research of air field in hearth on cold and hot conditions. and the law is found of air speed distribution by measuring its speed and distribution of upper and lower deck on cold condition, thus it lays the foundation for analysis on hot condition. under four burning states, we measure the air speed in single, double - deck, and find out its corresponding distribution law
5 .根據有限元分割原理布置測點,採用降溫方法,用k五江9106等儀器分別測出單雙爐排燃燒方式4種不同工況下,該燃燒設備爐膛內coz 、 02 、 co氣體濃度,並找到了隨爐膛高度方向及深度方向變化規律;從燃燒原理分析評價了2種燃燒方式爐膛內coz 、 02 、 co氣體濃度場分佈特點及相應燃料層內乾燥、干餾、氧化、還原、灰渣層厚度,肯定了雙層爐排燃燒方式爐膛中c02 、 02 、 co氣體濃度場分佈合理性,從燃燒理論找出了最佳濃度場分佈狀態及燃料層內各反應層厚度。Standard test method for determining whether gas - leak - detector fluid solutions can cause stress corrosion cracking of brass alloys
測定氣漏檢測器液體溶劑是否能引起黃銅合金應力腐蝕斷裂的標準試驗方法In the case of a single medicinal gas filled via a multi - cylinder manifold, at least one cylinder of product from each manifold filling should be tested for identity, assay and if necessary water content each time the cylinders are changed on the manifold
在用多頭分配器給多個氣瓶灌裝同一種醫用氣體的情況下,對每組多頭分配器至少要對一個氣瓶進行鑒別和分析,必要時,每次更換氣瓶時還須測定水份含量。Intravenous medication pumps allow the nursing staff to titrate medications ; foley catheters and urine collection bags aid in monitoring urine output ; sequential compression devices squeeze the lower extremities and reduce the incidence of deep venous thrombosis ; transvenous pacemakers stimulate the patient ' s heart to beat ; dialysis machines remove fluid and correct electrolyte and acid - base disturbances ; intraaortic balloon pumps assist the heart ' s contractility ; and neurologic monitoring systems measure intracranial pressure
靜脈內給藥泵由普通護士用於滴定藥物;弗利氏導管和集尿袋幫助監測排尿量;連續壓迫裝置擠壓下肢,減少深部靜脈血栓形成;經靜脈起搏器刺激病人心臟跳動;透析儀除去液體,糾正電解質和酸堿紊亂;主動脈內氣囊泵支持心臟收縮;神經病學監測系統測定顱內壓。Our next - generation high - resolution spectrometer is a novel combination of optics and electronics that is ideal for applications such as characterizing lasers, measuring gas absorbance, and determining atomic emission lines
我們下一代高解析度分光計,是一種新的光學和電子學器件的組合,對在激光特徵分析,測量氣體吸光率和確定原子散射線等領域的應用很理想。Pneumatic fluid power - compressed air lubricators - test methods to determine the main characteristics to be included in supplier ' s literature
氣動流體動力.壓縮空氣潤滑器.供貨商文件包括主要特性測定的試驗方法Section : laboratory experiment was carried out to determine mercury accumulation in four organs that were gills, heart, hepatopancreas and gonad of freshwater crab sinopotamon yangtsekiense by using atomic absorption method
汞在長江華溪蟹四種器官的積累以體外暴露的方式,採用還原氣化原子吸收的方法,測定了長江華溪蟹鰓、心臟、肝胰腺和性腺中汞的積累情況。Stationary source emissions. determination of the mass concentration of total gaseous organic carbon at low concentrations in flue gases. continuous flame ionisation detector method
穩定源輻射.煙道低濃度氣體氣化有機碳濃縮總量的測定.連續火焰離子檢測器法Following, we developed an electronic nose adopting advanced technology which combined capillary column to separate vocs according their different retention time and surface acoustic wave sensor coating with polymer film to detect the qualities of those vocs. in my article, lung cancer situation, breath detection principle, feasibility of electronic nose adopting breath detection, and the principles of spme & gc have been particularly introduced. and initially certified the correlation between lung cancer and the marker vocs by detecting lung cancer patients breath, normal human breath, and lung problem patients by solid phase microextraction ( spme ) and gas chromatography ( gc ) system
本課題根據國外關于呼吸氣體中某些有機氣體成分和肺癌相關性的研究工作報告,採用固相微萃取?氣相色譜系統對肺癌病人呼吸氣體、正常人呼吸氣體、和其它類肺病患者呼吸氣體中的有機氣體成分進行對比檢測、研究,以期確定肺癌病人呼吸氣體中特徵有機氣體成分;並且期望建立首創的採用毛細管色譜柱與聲表面波傳感器聯用技術的電子鼻系統,與固相微萃取?氣相色譜系統作為對比檢測,能夠做到粗篩肺癌病人。Co 2tr test method for the determination of carbon dioxide gas transmission rate co 2tr through barrier materials using an infrared detecto
用紅外線探測器透過隔絕材料測定二氧化碳氣體傳輸率An instrument for measuring the force or volume of inspiration or expiration in the lungs
呼吸氣量測定器;肺活量計用以測量肺部吸入或呼出空氣的力量或體積的一種儀器To analyze the questions and errors occurred in measuring the leaf photosynthetic rate using gas exchange, instrumental error, observation error and biology error in the use of portable photosynthesis system were computed and analyzed
為了了解紅外氣體分析法測定單葉光合速率中常見問題及產生的誤差,本研究對光合作用測定系統使用中的儀器誤差、觀測誤差和生物誤差進行較為全面的實驗和分析。The combustible gas detector should be of high stability and seldom producing zero - point drift during normal working. it should be able to automatically compensate zero - point drift
可燃氣體檢測器應穩定性高,正常工作時應很少產生零點漂移。應具有零點漂移自動補償功能。儀表的零點和滿量程應能夠在現場進行標定。As the key of the sample injection, a digital control instrument of mass flow controller ( mfc ), which can work in online and offline mode, was designed. it can give 4 flow signals accurately at the same time. the concentration and flux of the sample gas can be set by the instrument software
進樣裝置的核心是自行設計開發的新型流量控制儀,該儀器採用數字介面,可以以聯機和脫機方式工作,能夠同時快速準確地輸出4路流量控制信號,對測試氣體的流量和濃度進行設定。In vitro injury models of brain slice ( ogd and nmda insult ) and primary neuronal cultures ( nmda insult ) oxygen / glucose deprivation ( ogd ) - induced injury of rat hippocampal slice in vitro the rat hippocampal slices prepared were allowed to recover in the normal artificial cerebrospinal fluid ( acsf ) bubbled with gas mixture of 95 % o2 + 5 % co2 for 1 h, then they were thansfered to glucose - free nacsf which was bubbled with gas mixture of 95 % n2 + 5 % co2. after treatment with ogd, the slices were placed into 2 % ttc solution in dark and incubated at 37 * cfor 1h. the slices were weighted and a 50 : 50 mixture of ethanol / dimethyl sulfoxide was then added to extract the formazan in dark for 24 h
離體腦片損傷模型( ogd和nmda )及原代培養神經元nmda損傷大鼠離體海馬腦片缺氧缺糖( ogd )損傷大鼠離體海馬腦片制備后,在通氧混合氣的正常腦脊液( nacsf )中恢復60min ,然後移入通氮混合氣的無糖腦脊液(吵化sf )中缺氧缺糖,取出腦片與2 ttc避光37 』 c溫浴60dll ,染色后根據每克濕重加入20ml抽提液(乙醇:二甲亞礬一50 : 50 ) ,在密閉容器內避光置24h ,測量前搖勻后取200pi至96孔板,在490urn波長,酶標儀測定各孔od值。Blood gas apparatus
血內氣體測定器分享友人