流量測量裝置 的英文怎麼說

中文拼音 [liúliángliángzhuāngzhì]
流量測量裝置 英文
flow measuring device
  • : Ⅰ動1 (液體移動; 流動) flow 2 (移動不定) drift; move; wander 3 (流傳; 傳播) spread 4 (向壞...
  • : 量動1. (度量) measure 2. (估量) estimate; size up
  • : 動詞1. (測量) survey; fathom; measure 2. (測度; 推測) conjecture; infer
  • : Ⅰ名詞1 (服裝) dress; outfit; attire; clothing 2 (演員的化裝品) stage makeup and costume Ⅱ動詞...
  • : 動詞1. (擱; 放) place; put; lay 2. (設立; 布置) set up; establish; arrange; fix up 3. (購置) buy; purchase
  • 流量 : rate of flow; flow; runoff; discharge; throughput; (flow) rate; quantity (of flow); flux
  • 測量 : measure; survey; gauge; meter; measurement; measuring; surveying; mensuration; metering; gauging;...
  • 裝置 : 1 (機器設備的配件)installation; device; apparatus; equipment; arrangement; gear; appliance; rig...
  1. Apparatus for measuring d. c. magnetic characteristic with ballistic galvanometer

    沖擊法直磁特性
  2. Company has possessed 600 employess, over 68manag. ement personnel and 22 technicians since is was founded. inwhich junior college graduatre account for 90 %, average ages of employees is 28 years, area of factory building is 20000sq. meter annusi value of production is 80 milions yuan and have three modemization production line and advanced equipment and perfct monitor and measunng device as puncher, driller, lathe, measurig truck, cutter, shielded welder and pipe bendin machine. main production of company are all kinds of generators, both petrol and dlesel series, water umps, luggage rack of vehicle, bumper, fuel tankall kinds of motorcycle rack, auto majhong machine and whd series of dlecmolishde vehide, wide varieties, a complete range of specification. the products have stable qusity and advanced

    具備廠房面積20000平方米,年產值8000多萬元的生產能力及三條現代化水線。擁有各種大型沖壓設備各類油箱鉆床車床儀表車切割機保護焊機彎管機等先進設備和完善的。公司主要品種有:各種發電機組汽油機系列柴油機系列水泵汽車行李架保險杠各種摩托車架全自動麻將桌whd系列電動滑板車,防墜器等系列產品。
  3. Measurement precision contribute to improving the security class and economic of boiler running and automatic level of whole plant. the smart measurement instrument of the boiler ’ s air flow designed in the thesis and the instrument can make the degree of accuracy get to. firstly, the thesis build the “ velocity - area ” method which is on basis of “ log - tchebycheff ” on the analyzing of basic measure method of boiler ’ s air flow. secondly, model86 averaging pitot tube was selected the right model of flow transducer which can pickoff the differential pressure and static pressure. modelc264 which made in setra system corp. u. s. a was selected as ultra low differential pressure transmitter. a good flow of boiler ’ s air was calculated by offsetting pressure and temperature. finally, numeroscope was designed with z80cpu and other chips

    精確的監有助於提高鍋爐燃燒的安全型、經濟性,也有助於提高電廠的整體自動化水平。本文設計的智能化鍋爐風能夠實現對鍋爐送風的精確,精度可達。本文首先研究鍋爐送風矩形大管道理論,提出在點布基於「對數-切比雪夫」法的速度-面積法。
  4. Flow measurement calibration facility pipe prover

    體積管式校準
  5. The seven - hole probe ( shp ) is a device which can simultaneously measure the pressure and velocities of the steady flow, especially at large angles

    作為一種可以同時獲得動速度的大小、方向、以及總壓和靜壓的氣動,七孔探針能夠被廣泛應用於各種大角度的
  6. The button electrode is one that widely used in high energy rf accelerators, such as storage ring, and the bpm made of button electrodes has many merits like high accuracy, high resolution, resisting magnetic field, simple machinery, without magnetic core and low cost, etc. so we want to use the button electrode as the bpm in high current accelerators like the lia

    鈕扣電極束位器是一種廣泛應用於射頻加速器儲存環等高能弱加速器的一種束位,它具有精度高、解析度高、不受磁場干擾、機械結構簡單、無磁芯、造價低廉等特點。只是,至今未見有關這種束位器在強加速器(如,直線感應加速器)上應用的報導,如能將鈕扣電極束位器應用於lia ,將是一件很有意義的事情。
  7. Flow measurement calibration device

    校準
  8. Practical flow-metering devices have become available commercially.

    實用的流量測量裝置已在工業上使用。
  9. Specification for double regulating globe valves and flow measurement devices for heating and chilled water systems

    加熱和冷卻水系統用雙調節球形閥和流量測量裝置規范
  10. Measurement of fluid flow by means of orifice plates, nozzles and venturi tubes inserted in circular cross - section conduits running full

    用孔板噴嘴和文丘里管充滿圓管的
  11. Flow measurement ; differential pressure devices with corner taps ; length of pressure taps stud and installation dimensions for determination of space required

    .帶彎壓接嘴的壓差.壓接嘴螺柱的長
  12. The bpm system that widely used in linear induction accelerator ( lia ) is beam bugs and b - dot

    在直線感應加速器中,廣泛使用的束位( bpm )有壁電器(電阻環)和磁探針( b - dot ) 。
  13. The influence arising from the anode voltage and gas pressure of gas - flow proportional counter and ambient temperature on the measuring error of the setup has been investigated by means of experiment

    實際得了氣正比計數管陽極高壓、工作氣壓和環境溫度對軟x射線熒光誤差的影響。
  14. Install the flow measurement device in a straight run of pipe making sure that the flow arrow on the flow measurement device points in the direction of the water flow

    在管道的直線段安流量測量裝置,確保流量測量裝置上的箭頭指向水向。
  15. On the downstream side, no fitting should be closer than 21 / 2 pipe diameters from the flow measurement device. ( five pipe diameters are preferred

    在下游段,距離流量測量裝置2 . 5倍管道直徑長度內不應該有連接件。 (最好是五倍管道直徑長度內) 。
  16. Flow measuring device

    流量測量裝置
  17. Flow measuring devices. meters for cold potable water. test methods and equipment

    流量測量裝置.冷飲用水的水表.試驗方法及設備
  18. Assessment of uncertainty in the calibration and use of flow measurement devices. part 2 : non - linear calibration relationships

    流量測量裝置校準和使用時誤差的評估.第2部分:非線性校準關系
  19. Assessment of uncertainty in the calibration and use of flow measurement devices. part 1 : linear calibration relationships

    流量測量裝置的校正和使用中的不確定度評定.第1部分:線性校正關系式
  20. Care must be taken during installation so that the flow measurement device fitting is concentric with the center line of the pipeline in which it is installed

    在安期間必須小心,使得流量測量裝置的中心與所安的管線中心對齊。
分享友人