測溫電橋 的英文怎麼說

中文拼音 [wēndiànqiáo]
測溫電橋 英文
bridge for measuring temperature
  • : 動詞1. (測量) survey; fathom; measure 2. (測度; 推測) conjecture; infer
  • : Ⅰ形容詞(不冷不熱) warm; lukewarm; hot; gentle; mild Ⅱ名詞1 (溫度) temperature 2 (瘟) acute ...
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : 名詞1. (橋梁) bridge 2. (姓氏) a surname
  1. Among various fabrication techniques of thin film, the sol - gel process has gained much interest for the preparation of pzt thin film, due to ihe advantages of good homogeneity, easy control of composition, low in - ill i reaving temperature, easy formation of large area thin films pb ( zrxti : - k ) 0 :, ( pzt ) films were prepared on the ito coated glass plates and low resistor silicon wafer in sol - gel dip - coating process associated wi di heat treatment : at different temperatures and characterized by x - ray diffraction ( xrd ) and transmission electron microscopy ( tem ). lt is shown that the pzt ferroelectric thin films with ( 110 ) preferred orientation and well - crystallized perovskite structure can be obtained after annealing at 680 ? for 30 minutes on ito substrate and at 800 " c for lornin on silicon substrate

    Pzt的制備方法有很多,其中溶膠?凝膠( sol - gel )方法可以和集成路( ic )光刻工藝相互兼容,處理度低,有大面積塗敷性能,能精確地控制組分,無需復雜的真空設備,成本低廉,所以對于集成鐵薄膜容的應用這種方法有很廣闊的前景。本文利用sol - gel技術在摻錫的in _ 2o _ 3透明導薄膜( ito )襯底和低阻硅襯底上成功地制備了pzt鐵薄膜。運用了x射線衍射, sawyer - tower路和lcr分別對薄膜的晶化度,結構和學性能進行了試。
  2. Self - balance display instruments for temperature measurement. guidance for the calculation of bridge resistance, scale and chart

    自動平衡式顯示儀表.阻標度尺和記錄紙的計算導則
  3. Verification regulation of the dc bridges for measuring temperature

    直流測溫電橋檢定規程
  4. A resolution method in software is applied to calibrate zero point and full scale of the circuit. software approach to nonlinear correction for sensor and circuit is presented. therefore system error is eliminated, and measurement accuracy of temperature is improved. the signal of acidity electrode is detected by a differential amplifier circuit, which consists of operational amplifiers tlc2254 with high input impedance and low drift

    採用路和單運放差動放大路對度傳感器信號檢放大,軟體校正度傳感器和路的非線性,軟體校準路的零點和滿度,消除路的系統誤差,提高補償度的量精度;採用高阻、低漂移運放tlc2254組成高阻差動放大路用於酸度極信號量。
  5. To the concrete two - phase flow - crude oil, its temperature, speed and capacitance value are measured by flat capacitance sensors, fluke rlc instrument and other auxiliary appliance. assessing the characters of crude oil and predicting the solidifying point is the result of using fuzzy information arithmetic

    針對具體的兩相流? ?原油,用平板容器、 fluke精密和其它輔助傳感器分別取了原油的熱處理度、降速率和容值,利用模糊信息融合演算法對量值進行處理和尋優,從而進行原油熱處理的綜合評定和凝點的在線預
  6. In this paper, a kind of improved practical active linear bridge circuit with platinum resistor is used to eliminate the error mentioned above, and the precise temperature measurement can be made

    本文採用鉑阻改進型實用有源線性化路克服了上述誤差,實現了高精度的量。
  7. In temperature measurement of the thermal resistor, the nonlinearity of thermal resistor, lead resistor and unbalanced bridge may produce errors

    摘要熱量中,熱阻的非線性、不平衡的非線性及引線阻都會給量帶來誤差。
分享友人