漏電絕緣子 的英文怎麼說

中文拼音 [lóudiànjuéyuánzi]
漏電絕緣子 英文
faulty insulator
  • : Ⅰ動詞1 (從孔或縫中滴下、透出或掉出) leak; drip 2 (泄漏) divulge; disclose; leak 3 (遺漏) le...
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : Ⅰ動詞(斷絕) cut off; sever Ⅱ形容詞1 (完全沒有了; 窮盡; 凈盡) exhausted; used up; finished 2 ...
  • : Ⅰ名詞1 (緣故) reason 2 (緣分) predestined relationship 3 (邊) edge; fringe; brink Ⅱ動詞(攀...
  • : 子Ⅰ名詞1 (兒子) son 2 (人的通稱) person 3 (古代特指有學問的男人) ancient title of respect f...
  • 漏電 : leakage of electricity; leakage漏電保護 earth leakage protection; 漏電保護開關 earth leakage circ...
  • 絕緣 : 1 [電學] (隔斷電流) insulation; isolation; insulate; isolate 2 (跟外界不發生接觸) be cut off ...
  1. Design of passive counter for monitoring leakage current of insulators

    無源型流監測計數器的設計
  2. By starting with the analysis of generator end structure and overheat sources, it is presented that the technical key required to expand the capacity of the unit is to solve the electromagnetic leakage shielding problem. by proceeding with the analysis of the reasons causing the aging of the stator winding bars insulation, the necessity for stator winding bars to adopt class f insulation and relative fixing technological improvement are pointed out so as to extend the service life of the winding bars insulation

    從分析發機端部結構及過熱原因入手,提出了增容的技術要點在於解決端部磁屏蔽問題;從發機線棒老化原因分析入手,指出為延長定線棒使用壽命,線棒主採用f級的必要性以及相關工藝的改進。
  3. Abstract : in this paper, characteristics of polluted insulator ' s operation state were analysised, studied the differences between each characteristics, the factors influencing lc significantly were found, including circumstance factors, and characteristics of leakage current ( lc ) were studied basing on artificial contamination test, obtained the relationship between leakage current and the influenced factors

    摘要:文章分析了表徵污穢運行狀態的特徵量,比較了各特徵量的特點及其適用場所,總結了影響泄流的特徵量,包括環境因素,並且在人工污穢試驗的基礎上,分析了泄流在閃絡過程中的特徵,得出了泄流與其基本特徵量之間的關系。
  4. Railway applications - insulation coordination - part 1 : basic requirements - clearances and creepage distances for all electrical and electronic equipment

    鐵路設施.協調.第1部分:基本要求.所有氣和設備的余隙距離和距離
  5. And so far, lots of investigation was conducted on the insulators " leakage current measurement and logging, but the investigation of the entireness process measurement and logging of the iced insulators flashover is also vacancy

    至今為止,雖然對流的檢測和記錄已進行了大量研究,但針對覆冰閃絡過程中泄流變化全過程的測量和記錄的研究仍然是空白。
  6. Electrical field stress at the icicle tips is even stronger. at these areas, if the electric field across air gaps is high enough, corona discharges are initiated. this can lead to the development of local arcs across the air gaps causing a substantial increase in leakage current and a concomitant melting of ice

    空氣間隙的存在使覆冰表面的場分佈發生了明顯畸變,間隙上承受了非常高的壓,這使得冰凌尖端的場變得相當強,一旦場達到了暈的起始場,局部放就在這一區域發生,進而產生局部弧並逐漸發展成整串的閃絡,泄流迅速增大,同時伴隨著冰的融化。
  7. Test results indicated : with the hoist of altitude, the increase of ice amount and the rise of pollutant, the average flashover voltage reduced. the character exponent generally depends on the insulator profile, ice amount, ice state and pollution severity etc. by means of a high - speed camera, a data acquisition system and high voltage test facilities, a series of the flashover processes on ice surfaces were record. the experimental results form this study and the subsequent theoretical analyses suggested : the thermal ionization of the air in front of an arc root resulted in arc movement ; the electrostatic force had an auxiliary effect of impelling arc propagation ; the electrical

    通過對攝像機、數據採集系統及高壓試驗裝置記錄覆冰表面閃絡弧的發展過程的試驗結果進行理論分析得出:弧根周圍空氣的熱離導致了弧的發展,靜場力對弧的發展起到了加速作用,擊穿僅發生在閃絡最終的跳躍階段;通過測量閃絡過程中的放壓、泄流、閃絡時間、覆冰水導率、弧長度及弧半徑等參數,得到了不同階段弧(弧起弧階段、弧發展階段及完全閃絡)的發展速度、臨界弧長度均隨覆冰水導率的增加而減小。
  8. Electronic co., ltd., a private hi - tech company, professionally makes and markets electronic instruments and gauges, such as digital torque tester, bottle cap torque tester, voltage resistance tester, grounding resistance tester, leakage current tester, insulation resistance tester and etc. lankers quality instruments and gauges are characterized by well - designed structure, high reliability and stability and outstanding performance and are well sold to users in the industries of home appliances, motorcycle, automobile, motor and pharmaceutical

    市藍光有限公司是一家集科研生產銷售於一體的高科技民營企業,公司擁有雄厚的技術實力,以卓越的設計能力,完備的工藝控制和完善可靠的檢測手段,向用戶提供高性價比的測量儀器。主要產品有:數字扭力測試儀系列瓶蓋扭力測試儀系列耐壓測試儀,接地阻測試儀,泄流測試儀,阻測試儀等安規測試儀系列。
  9. On the base of the theory of the adaptive noise cancellation and the adaptive line enhancement, we have made an improved adaptive noise cancellation in use of the measuring of hv insulator ' s leakage current

    結合普通自適應噪聲對消和自適應譜線增強原理,提出了一種改進型自適應噪聲對消器,用於高壓流檢測。
  10. In order to improve the circuit ' s input impedance, which is affected by insulating resistance of electrode leading wire, terminals and printed circuit board, electrode is connected to the meter through insulating wire of high impedance which is directly welded in the printed circuit board with insulating ring. the deviation of electrode is corrected by software and the algorithm is given

    使用高阻線連接極,並將高阻線直接焊在加有環的印刷線路板上,從而消除極引線、接線端和印刷線路板對放大路輸入阻抗的影響;軟體校正極偏差,並給出校準演算法。
  11. Utilities spends significant amounts of money on insulator washing and cleaning before the restoration of the service. laboratory studies and industrial experience have shown that both contamination and wetting of insulator surfaces, which initiate the flow of leakage current, are required for insulator flashover. the leakage current leading to flashover has distinctive stages of development

    人們在詳盡的理論分析和大量的高壓實驗后,發現流的變化與其污穢及受潮程度有著密切的關系,綜合反映了污閃的發生過程,因此泄流檢測是診斷線路早期故障的一種有效手段。
  12. Organic - inorganic nanocomposite, which are the complex of inorganic nanopraticles with organic compound, is a popular study subject in nanoscale composite. the nanocomposite can not only take advantage of several advantage, but also produce new properties. in this thesis, taking account of the problems in electrorheological fluids such as high leakage current, low yield stress and stability, the pan - batio3 nanocomposite with different structure are prepared by in - situ complex technology and modified sol - gel method

    根據目前流變液中出現的問題(如屈服應力不夠高,流密度不夠低,穩定性不夠好等問題) ,基於聚苯胺有較高的熱穩定性,且密度又小,特別是聚苯胺的介常數和導率均可按需調整,此外,鈦酸鋇無機納米粒作為一種無機鐵體,在場作用下具有自發極化的能力,一方面可以為體系提供高的介常數,另一方面又可保證體系的性能。
  13. Based on the currently laboratory investigation results and the iced insulators leakage current performance during icing process, in this paper a leakage current measurement system is designed with graphical programming language laboratory virtual instrument engineering workbench

    本文在國內外現有研究成果的基礎上,根據覆冰閃絡過程中泄流特性和測量要求,應用圖形化編程語言labview設計了基於虛擬儀器的冰閃過程泄流檢測系統。
  14. Insulators leakage current has a close relationship with insulators contamination and humidity state, so it can provide an integrated reflection of the course of contamination flashover. the contamination flashover on - line monitoring device introduced in this paper predominates the insulators insulation degree by measuring leakage current, environment temperature and humidity. with the help of the device, an active partial aperiodic cleaning method will substitute the former passive general fixed cleaning method in order to prevent the contamination flashover to a larger extent

    本文所描述的防污閃在線監測系統通過直接測量表面的泄流及環境的溫度和濕度,經過數據處理、分析、判斷,達到對狀況實時監測的目的,以此為依據變定期的、全面的、被動的清洗為不定期的、局部的、主動的清洗,最大程度地防止污閃事故的發生。
  15. It is proposed that in order to increase the reliability of prediction, the nonlinear prediction model, which depends on the nonlinear relationships between above factors, is indispensable

    提出要提高報警的可靠性必須利用泄流、溫度、濕度與污穢程度的非線性關系,進行非線性報警。
  16. An economical and effective new technology using sound card is proposed in this paper. it collects the leakage current from high voltage insulator, and then deals with the noise elimination using wavelet analysis. compared with the traditional signal analyzing method, the wavelet analyzing technology not only can distill the leakage current signal from the noise precisely, but also can distinguish the low quality character of leakage current signal. this method plays an important role to the device in early fault diagnosis, and can improve the accuracy of measurement and fault diagnosis in the application

    介紹了一種利用腦的聲卡對高壓的泄流進行採集的經濟有效的新技術,並通過小波分析技術對所獲得的信號進行消噪處理.與傳統的信號分析方法相比,小波分析技術不僅能從噪聲中準確提取待測泄流信號,同時又可真實復現泄流信號中的劣化特徵,這對設備的早期故障診斷具有重要意義.顯著提高了測量的準確度,增強了設備故障診斷的準確性
  17. Flashover is preceded by dry - band arcing and extension of the arc to bridge the insulator. this combination significantly modifies both the magnitude and shape of the leakage current

    本文在檢索大量國內外參考文獻及研究成果的基礎上,提出一種性能價格比優良的線路在線監測方案? ?基於msp430的輸流檢測。
分享友人