  1. And it investigates the appearance condition ( including joint, crack, eroding, corrosion, braking pole device rupture, crane - girder ' s gnawing railway and so on ) of the whole crane - girder system on the spot, at the same time, it also actually examines the stress of the beam, chemical ingredient, distortion and railway excursion, etc. through sampling, and based on the actually examined results, it checks and calculates the carrying capacity of crane - girder system. then, based on the investigating on the spot and the calculated result, it discusses the mechanism of fatigue failure of the upper part of welded steel crane - girder, analyses the reason of steel crane - girder in the high - frequency emerging the fatigue crack, institutes the strengthened method of damaged steel crane - girder of accurate packing up workshop of the primary mill plant. finally, it presents some advice and suggestions for the repairing and strengthening method of fatigue crack of upper part of steel crane - girder in the high - frequency

    針對包鋼初軋廠精整車間鋼吊車樑上部區域出現這一問題,本文首先綜述了國內外關于接鋼吊車樑上部區域疲勞的研究現狀;其次對整個吊車梁系統的外觀情況(包括連接、、腐蝕、銹蝕、制動桿件斷、吊車啃軌等)進行了現場調查,抽樣實測了梁的應力、化學成分、變形及軌道偏移等,根據實測結果,對吊車梁系統的承載能力進行了驗算;然後,根據現場調查及計算結果,探討了接鋼吊車樑上部區域疲勞壞的機理,分析了重級工作制鋼吊車梁出現疲勞的原因,制定了初軋廠精整車間損鋼吊車梁的加固方案;最後就重級工作制鋼吊車樑上部區域出現疲勞的修復與加固方案提出了一些意見和建議。
  2. The liner of turbine draft tube in ankang water power station was punched by cavitation, which leads to welding crack, metal shed and concrete delve, water spurting out. the cause of the damage is analyzed, the treatment is expounded

    論述了安康水電站水輪機尾水管里襯被汽蝕壞穿透、、撕掉塊、混凝土掏空、大量噴水的事故原因及處理方法。
  3. Abstract : the liner of turbine draft tube in ankang water power station was punched by cavitation, which leads to welding crack, metal shed and concrete delve, water spurting out. the cause of the damage is analyzed, the treatment is expounded

    文摘:論述了安康水電站水輪機尾水管里襯被汽蝕壞穿透、、撕掉塊、混凝土掏空、大量噴水的事故原因及處理方法。
  4. Fractures in the weld root on column fusion face are typical earthquake damage to steel frames. the object of this paper is computer simulation of typical seismic damage to steel frame structures

    樑柱節點是鋼框架結構震害中的典型壞模式,本課題研究的目標是對鋼框架結構這種典型的震害進行計算機模擬。
  5. The main contests and conclusions are listed as follows : 1 the failure modes and location of steel frame were analyzed under static loads. the failure modes included strength failure and stability failure. the failure modes of steel frame were introduced under earthquake loads

    本文主要研究內容和相應的研究成果概括如下: 1通過對鋼框架結構在靜力豎向荷載和水平荷載作用下壞現象和規律的分析,說明樑柱節點受力大、強度低是造成地震中大量鋼框架結構房屋樑柱節點的主要原因。