Then the paper uses the same typical four network operating conditions as the primary given conditions and when adding one set of the parallel capacitor bank, changing the 330 / 220kv transformer tap changer position step by step to change the transformer ration, through this study methods this paper found out all the optimized combination of the tap changer position and the amount of input reactive power, also obtained four sets of the 330kv, 220kv and hokv s / s bus voltage and the active and reactive power losses changing curves. through analyzing the optimized combination control curve and the network power flow, the paper generalizes the rules as following : the chief measure of coordinative control is inputting shunt reactor in chengxian s / s in winter time both in the planning year of 2010 & 2005 ; in summer time in planning year of 2010 the chief measure is to input proper shunt capacitor
本研究通過分析所獲得的最優綜合控制組合曲線及電網潮流,總結出了如下規則:隴南電網在2005年及2010年冬大、以及2005年夏小運行方式下,綜合控制應以成縣變投入適量並聯補償電抗器作為主要措施;在2010年夏小運行方式下則投入適量並聯補償電容器作為主要措施,再輔助以選擇合適的主變有載調壓分接頭來調節,達到控制網內無功潮流分佈合理、各變電站母線電壓在理想的范圍內時電網有功損耗最小,從而也提高了電網安全運行水平及供電質量。Capacitors dispatch of distribution system is an efficient method to network loss reduction and voltage improvement in the distribution system operation. it is an important component of distribution automation system ( das ). the thesis mainly discusses reactive optimal control of distribution system
首先,研究了配電網無功優化控制的基本理論,討論了配電網無功優化控制對電壓和有功損耗的影響,提出配電饋線電容器優化控制對進一步降低配電網的有功損耗效果顯著。In this part, the high - frequency series inverter with resonant pole capacitor is introduced mainly. the current - exchanging processes of the inverter in different working modes are analyzed, how to reduce the switching loss is discussed, and the calculating methods of snubber capacitor c, factor angle switching frequency and pulse width pw are given in optimum switching process. and results of simulation and experiment verify the validity of theoretic analysis
接著重點研究了含有諧振極無損緩沖電容的逆變器,對其換流過程中的不同工作狀態進行分析,討論了如何減小逆變器的開關損耗,給出了最佳工作狀態下緩沖電容c 、感性角、開關頻率、觸發脈沖的脈寬pw的詳細計算方法,並通過大量的模擬和實驗波形證明了理論分析的正確性。The electric power harmonic comprehensive control system with low cast and high security is applied in this article. it adopts that sourced compensation links with non - sourced compensation herewhich the former is realized by high frequency pwm control technology and the latter is carried out by crystal switch formed by non - flow and over - voltage. it can realize stepless modulation with imaginary power, mightiness compensation of harmonic and negative electricity, and circuitry consumption debasing are achieved
提出採用有源補償與無源補償相結合的電力諧波綜合治理技術及裝置,無源部分採用無涌流和過電壓的晶閘管控制電容器技術實現,有源部分採用高頻pwm控制技術實現,成本低、可靠性高、可實現無功功率的無級調節、強力補償諧波電流和負序電流,降低線路損耗。分享友人