無損耗電容器 的英文怎麼說

中文拼音 [sǔnhàodiànróng]
無損耗電容器 英文
non-lo conde er
  • : 無Ⅰ動詞(沒有) not have; there is not; be without Ⅱ名詞1 (沒有) nothing; nil 2 (姓氏) a surn...
  • : Ⅰ動詞1 (減少) decrease; lose 2 (損害) harm; damage 3 [方言] (用尖刻的話挖苦人) speak sarcas...
  • : Ⅰ動1 (減損; 消耗) consume; cost 2 [方言] (拖延) waste time; dawdle Ⅱ名詞1 (壞的音信或消息) ...
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  • 無損 : lossless
  • 耗電 : power consumption
  1. Then the paper uses the same typical four network operating conditions as the primary given conditions and when adding one set of the parallel capacitor bank, changing the 330 / 220kv transformer tap changer position step by step to change the transformer ration, through this study methods this paper found out all the optimized combination of the tap changer position and the amount of input reactive power, also obtained four sets of the 330kv, 220kv and hokv s / s bus voltage and the active and reactive power losses changing curves. through analyzing the optimized combination control curve and the network power flow, the paper generalizes the rules as following : the chief measure of coordinative control is inputting shunt reactor in chengxian s / s in winter time both in the planning year of 2010 & 2005 ; in summer time in planning year of 2010 the chief measure is to input proper shunt capacitor

    本研究通過分析所獲得的最優綜合控制組合曲線及網潮流,總結出了如下規則:隴南網在2005年及2010年冬大、以及2005年夏小運行方式下,綜合控制應以成縣變投入適量並聯補償作為主要措施;在2010年夏小運行方式下則投入適量並聯補償作為主要措施,再輔助以選擇合適的主變有載調壓分接頭來調節,達到控制網內功潮流分佈合理、各變站母線壓在理想的范圍內時網有功最小,從而也提高了網安全運行水平及供質量。
  2. Capacitors dispatch of distribution system is an efficient method to network loss reduction and voltage improvement in the distribution system operation. it is an important component of distribution automation system ( das ). the thesis mainly discusses reactive optimal control of distribution system

    首先,研究了配功優化控制的基本理論,討論了配功優化控制對壓和有功的影響,提出配饋線優化控制對進一步降低配網的有功效果顯著。
  3. In this part, the high - frequency series inverter with resonant pole capacitor is introduced mainly. the current - exchanging processes of the inverter in different working modes are analyzed, how to reduce the switching loss is discussed, and the calculating methods of snubber capacitor c, factor angle switching frequency and pulse width pw are given in optimum switching process. and results of simulation and experiment verify the validity of theoretic analysis

    接著重點研究了含有諧振極緩沖的逆變,對其換流過程中的不同工作狀態進行分析,討論了如何減小逆變的開關,給出了最佳工作狀態下緩沖c 、感性角、開關頻率、觸發脈沖的脈寬pw的詳細計算方法,並通過大量的模擬和實驗波形證明了理論分析的正確性。
  4. The electric power harmonic comprehensive control system with low cast and high security is applied in this article. it adopts that sourced compensation links with non - sourced compensation herewhich the former is realized by high frequency pwm control technology and the latter is carried out by crystal switch formed by non - flow and over - voltage. it can realize stepless modulation with imaginary power, mightiness compensation of harmonic and negative electricity, and circuitry consumption debasing are achieved

    提出採用有源補償與源補償相結合的力諧波綜合治理技術及裝置,源部分採用涌流和過壓的晶閘管控制技術實現,有源部分採用高頻pwm控制技術實現,成本低、可靠性高、可實現功功率的級調節、強力補償諧波流和負序流,降低線路
分享友人