  1. Exchange non - clearane metal oxidate matter arrester is suitabe for the voltage protection of transformer switch cupboard, vacuum switch etc

    間隙金屬氧化物避雷器,適用於變壓器、配電屏、開關櫃、真空開關、輸電線路、電力箱、並聯電容器、旋轉電機等電壓保護。
  2. Now the affect and the measure of hypo _ harmonics is in the research. the influence of negative sequence is almost eliminated along with the enlargement of the system ' s capacity and the alternate connection of traction substations. the fixed parallel compensate equipment applied in traction substations consist of a constant capacitor and a constant inductance, so its output is constant

    負序電的問題已經因系統容的增大、牽引變電所採用輪換接線方式而基本解決,電力部門實行的「反轉正」 ,使採用對功功率固定方式由於牽引負荷變化頻繁而出現不足或過現象,難以達到滿意效果。
  3. Aiming at the fact that power factor of low - voltage power equipment is very low in china and application condition of fieldbus technology in the world, based on enhancing power factor of ac motor, lowering losses of the reactive power, improving power quality, therefore, it is of great significance and practical value to research the reactive power compensation by applying the technology of fieldbus, computer and power electronics

    針對目前國內低壓設備用電負載功率因數偏低和國內外現場總線技術的應用現狀,基於提高交電機的功率因數、降低功功率損耗和改善電能質,本文綜合運用現場總線技術、算機技術和電力電子技術對交電機功功率的有關方面進行了研究,其研究成果具有一定的理論意義和實用價值。
  4. At the same time, the method of disposal phase shift of ct by compensation is introduced. then the analysis and statistic of electrical power quality, the control scheme and compensating amount of capacitor for reactive power compensation are analyzed respectively. and in the paper, the control with a / y and the switch with ac contactor and solid state switch is valid measure not only for improving operate level economically and amending electrical power quality but also for avoiding of replacing switch frequently and decrease economic loss

    然後對現有的演算法進行了詳細的分析、比較,篩選出既能滿足硬體要求又可降低投資、保證精度、簡化軟體的方案,確定了準同步采樣的方案,並通過對準同步采樣誤差的分析,提出了一種從45開始采樣,從而提高精度的采樣數據處理辦法,同時,對于電互感器相位漂移提出了一種辦法,接著對裝置中電能質分析與統以及中電容器的、投切原則也作了相應分析,其中對于採用y混合接線,並利用交接觸器和固態開關共同投切電容,不但提高了經濟運行水平、改善了電能質,而且有效的避免了頻繁更換開關,減少了經濟損失;最後,設了裝置的硬體電路並繪制了相應的軟體程圖。
  5. ( 2 ) in term of two cases that being upstream long - liu regulation or not, solved optimal model to obtained compensation results of water supply and generation electricity. the ning - meng system increased water 17. 08 * 10a8 m3, the downstream system increased 7. 13 * 10a8 m3 ; the runoff power stations increased generation 8. 93 * 10a8 kw - h, the san - xiao increased 9. 10 * 10a8 kw - h

    ( 2 )按照「」龍劉調節和「有」龍劉調節兩種情況,分別進行模型求解算,對比分析得到黃河上游水電站為中下游提供的水以及電調節結果:多年平均上游水電站為寧蒙灌區增加有效供水17 . 08億m ~ 3 ,為下游省市增加有效供水7 . 13億m ~ 3 ;為上游徑式電站增加電8 . 93億kw ? h ,為三小增加電9 . 10億kw ? h 。
  6. Reactive power are calculated using the new algorithm. on the basis of analyzing different kinds of control strategies of var compensation, the paper applies the criterion of voltage and var to control switching and illustrates a improved mode of switching capacitor which can prevent the switched - capacitor from the impacting of instantaneous rush currents by means of zero - crossing triggering of scr components, and can realize auto - tracking var and auto - switching shunt capacitor bank. initial operating parameters are stored in information flash memory of the mcu using flash self - programming technique in order to decrease complexity of the circuit and improve stability

    高壓智能控制器以flash型16位單片機msp430f149為控制核心,採用了一種相角實時測的新演算法,並在此基礎上算出了功率因數、有功和功,減少了運算提高了精度;在分析了各種控制策略的基礎上,以母線電壓和功功率復合判據控制投切,並提出一種改進的電容器投切方式? ?暫態投切控制晶閘管過零觸發,避免了電容器投切時的電沖擊;穩態運行時接觸器替代晶閘管,實現的自動跟蹤和電容器的自動投切,解決了投切時的暫態電沖擊和穩態時可靠運行的難題;控制器的原始運行參數採用flash自編程技術,將其保存在msp430f149片內的信息flash中,簡化了硬體電路,大大提高了系統的可靠性。
  7. Based on such background this system brings forward microcomputer monitoring and controlling technique to pvc process in production, researches ipc - plc distributed control system, applies new algorithm of measurement, realizes automatic compensation of dropping of material and automatic amendment of high - speed measurement in the dynamic measurement, improves dynamic measurement precision and speed in pvc continual production. at the same time, this system accomplishes the whole process in airtight pipelines and storehouses, realizes dustless production, clean producing condition, automation, scientific management, meets the demand of modern production, makes some new exploration and creation in production of pvc industry

    基於這樣的背景,本論文對pvc塑料生產的整個工序提出算機監控技術,研製出ipc - plcdcs系統,運用一定的給料演算法,實現系統動態稱中落差的自動與粗給料設定值的自動修正,提高了pvc連續生產中動態稱的精度與速度,並將整個生產工藝規劃於密閉管路和各種料倉中進行,實現作業塵化、環境優化、生產自動化與管理科學化,適應當前現代化生產的需求,為pvc塑料工業的發展作出新的探索與創新。
  8. That is, through analysis of the principle on flow control and " hydraulic transistor ", design and calculation of flow control characteristic as well as main parts in valve inner chamber, a piloted reducing valve will be installed between main valve and pilot valve. after a pressure - difference compensating reducing valve was added in the non - pressure compensating piloted reducing valve of the flow control valve in vlalvistor valve, the calculation on control characteristic emulation and load characteristic emulation has been carried out. the result of the calculation shows that after pressure compensating reducing valve was added, the linearity of the control characteristics has been greatly improved thus eliminating influence upon outlet flow by load pressure - change of the hydraulic system and improving performance characteristics of the hydraulic component

    文章還在對瑞典valvistor閥的插裝比例閥研究的基礎上,提出了一種新的控制原理,即:通過對控制和「液壓晶體管」原理的分析、控制特性及閥內腔主要結構件的設算,在主閥和導閥之間增設先導減壓閥,並進一步對valvistor閥的控制閥之壓力先導減壓閥、加入壓差減壓閥后的控制特性進行了模擬算和負載特性模擬算,結果表明:增設壓力先導增壓閥后,其控制特性曲線變得非常線性,從而消除了液壓系統負載壓力變化對主閥輸出的影響。