  1. Via the analysis of heat balance computation model and the computation of online heat balance for industrial coal boiler, this dissertation researched overall input heat, efficient utilized quantity of heat, heat losing of discharge flue gas, heat losing of chemistry and mechanism incomplete combustion, heat losing of dispelling heat of boiler, heat efficiency, air superfluous coefficient, wind speed, wind quantity, computation of primary air circle cutting and whose influence on boiler combustion efficiency

    本文通過對工業煤粉鍋爐平衡計算模型的析,利用在線平衡計算,研究了總輸入、有效利用量、排煙、化學不完全燃燒、機械不完全燃燒、鍋爐效率、空氣過剩系數、風速、風量及一次風切圓計算以及這些因素對鍋爐燃燒效率的影響。
  2. However carefully boiler casings and steam pipes are sealed, some heat escapes and is lost

    不管鍋爐與蒸汽管封閉的多麼嚴密,還是有一部耗掉。
  3. Abstract : the causes for low efficiency of the heater in no. 2 crude unit of jpc refinery are described and analyzed including water leaking of steam soot blower, dew point corrosion caused by steam, soot deposits in convection chamber owning to poor soot blowing, high flue gas temperature, no heat recovery of flue gas, and poor performance of insulation lining, etc. by using sonic soot removing system, flue gas recovery system, spray coating of fiber and rock wool, as well as adjustment of flow scheme accordingly in the technical revamping. the dew point corrosion is completely eliminated, the insulation performance is improved, the heat loss is reduced by 1. 25 %, the flue gas temperature is reduced to about 170, and the heater efficiency is increased from 83 % to more than 90 %

    文摘:析了金陵石油化工公司煉油廠二套常減壓裝置加爐存在的因蒸汽吹灰器漏水,蒸汽引起露點腐蝕及吹灰效果差造成對流室積灰,排煙溫度高,煙氣量未回收利用以及爐子保溫襯里效果差等問題,提出採用聲波除灰系統、煙氣回收系統、纖維噴塗和巖棉噴塗及相應的流程調整等改造措施.測定結果表明,本次技術改造解決了因蒸汽吹灰器漏水所造成的露點腐蝕問題,提高了保溫效果,減少1 . 25 % ,排煙溫度降至170左右,裝置的爐效率由83 %左右提高到90 %以上
  4. The causes for low efficiency of the heater in no. 2 crude unit of jpc refinery are described and analyzed including water leaking of steam soot blower, dew point corrosion caused by steam, soot deposits in convection chamber owning to poor soot blowing, high flue gas temperature, no heat recovery of flue gas, and poor performance of insulation lining, etc. by using sonic soot removing system, flue gas recovery system, spray coating of fiber and rock wool, as well as adjustment of flow scheme accordingly in the technical revamping. the dew point corrosion is completely eliminated, the insulation performance is improved, the heat loss is reduced by 1. 25 %, the flue gas temperature is reduced to about 170, and the heater efficiency is increased from 83 % to more than 90 %

    析了金陵石油化工公司煉油廠二套常減壓裝置加爐存在的因蒸汽吹灰器漏水,蒸汽引起露點腐蝕及吹灰效果差造成對流室積灰,排煙溫度高,煙氣量未回收利用以及爐子保溫襯里效果差等問題,提出採用聲波除灰系統、煙氣回收系統、纖維噴塗和巖棉噴塗及相應的流程調整等改造措施.測定結果表明,本次技術改造解決了因蒸汽吹灰器漏水所造成的露點腐蝕問題,提高了保溫效果,減少1 . 25 % ,排煙溫度降至170左右,裝置的爐效率由83 %左右提高到90 %以上
  5. The phase structure of different cu - fe thin films were studied by using grazing incidence x - ray analysis ( gixa ). the texture and residual stress of different cu - fe thin films were measured by scan of x - ray diffraction ( xrd ) and 2 scan with different. the thicknesses of different thin films were characterized by means of small angle x - ray scattering ( saxs ) technique. by using atomic force microscope ( afm ) measured surface roughness of thin films. the component of different thin film was characterized by energy disperse spectrum ( eds ) and x - ray fluorescence ( xrf ). the magnetic properties of cu - fe thin films were measured by means of vibrating sample magnetometer ( vsm ). in addition, the giant magnetoresistance ( gmr ) effects of different films were also measured. the original resistance of the film fabricated by a direction - current magnetron sputtering system is directly affected by bias voltage

    利用掠入射x射線析( gixa )技術對不同cu - fe薄膜的相結構進行了研究;利用xrd掃描及不同角度的2掃描對薄膜進行了結晶織構及殘余應力析;運用小角x射線射( saxs )技術測量了薄膜的厚度;採用原子力顯微鏡( afm )觀察了薄膜的表面形貌;運用能量譜( eds )及x射線熒光光譜( xrf )對薄膜進行了成標定;使用振動樣品磁強計測量了不同cu - fe過飽和固溶體薄膜的磁性能;最後利用自製的磁阻性能測試設備測量了真空磁場處理前後不同薄膜的巨磁阻值。
  6. Points out the irrationality of the prescription in the standard, and analyses and studies the correlative regulations in the russian standards

    指出該通則中對允許最大值的規定存在不妥之處,並析和研究了俄羅斯相關國家標準中的有關規定。