熱盤管 的英文怎麼說

中文拼音 [pánguǎn]
熱盤管 英文
heating coil
  • : Ⅰ名詞1 (盤子) tray; plate; dish 2 (形狀或功用像盤的東西) sth shaped like or used as a tray pl...
  • : Ⅰ名詞1 (管子) pipe; tube 2 (吹奏的樂器) wind musical instrument 3 (形狀似管的電器件) valve;...
  1. In model zw. the indirect heating still is omitted. the condensor adapts calandria heat exchanger. of course the screw plate heat exchange and coil pipe cooler can also be provided as request. when adapt coil pipe cooler, the buffer tank

    冷凝器採用列式換器,也可根據用戶要求供應螺旋板式換器,冷卻器採用式冷卻器,採用式冷卻器並配套供應穩壓罐和比重測定器。
  2. As for the dehumidifying conditions, the condensing rate for the humid air increases with reynolds number but decreases as the inlet temperature of cold water increases

    同時濕傳量及除濕率亦也隨著冰水入口溫度的降低而增加,顯比隨著冰水溫度的降低而減小。
  3. Total conductivity of heat exchanger of ellipse spiral ophidian coils

    正交橢圓螺旋器的總傳系數
  4. Cooling coils are introduced into the regenerator to control the temperature and remove the excess heat.

    在再生器中放進冷卻能控制溫度,也能除去過多的量。
  5. The reheat coil adjusts supply air temperature to offset building heat losses due to transmission.

    熱盤管調節送風溫度,以補償因傳造成的建築損失。
  6. The sensible heat factors are found to increase with both reynolds number and inlet temperature of cold water

    傳量隨著入口風速與鰭片數目的增加而增加,顯比及除濕率亦隨著風速增加而增大。
  7. Eaction vessel, electric heating, steam heating, outer coil reaction vessel

    反應鍋電加蒸氣加反應鍋
  8. Thermosiphon solar collectors provides mains pressure pre - heating via a high efficiency copper coil heat exchanger located within the solar collector tank

    虹吸式太陽能水器通過放置在集水箱中的高效能銅提供高壓力的水。
  9. Thermosiphon series solar water heater is our newest products, adopt the copper coil, it improves the problem of traditional solar water heater, like the hot water is limited, few out water, heat for long time, the water quality is worse and worse

    虹吸式太陽能水器是我們所開發的最新產品,採用銅式,此款彌補了傳統式太陽能水量有限出水量少加時間長水質越來越差等問題。
  10. Heat exchangers. forced circulation air - cooling and air - heating coils. test procedures for establishing the performance

    交換器.強制循環空氣冷卻和空氣加熱盤管.確定性能的試驗程序
  11. Heat exchangers - forced circulation air - cooling and air - heating coils - test procedures for establishing the performance

    交換器.強制循環空氣冷卻和空氣加熱盤管.性能確定的試驗規程
  12. In this case, tightly fitting dampers are required to prevent reverse thermosiphoning at night, which could freeze water in the heat exchanger coil

    在這種情況下,需要緊密配合的閥來阻止夜間反向虹吸,以防止水在交換器中被冷凍。
  13. Heat exchangers. hydronic room fan coil units. test procedures for establishing the performance

    交換器.室內液壓風機裝置.確定性能的試驗程序
  14. Dynamic model and simulation of fan - coil heat exchanger

    風機器動態換模型及計算機模擬
  15. The paper analyzes the non - lineal relations of the quantity of heat exchange and water flux of coil exchanger in part - load operating condition, the shortage of deciding the water flux in bypass pipe, the disadvantage that the operating condition of pumps and chiller ca n ' t be met with the load change of the air conditioning system in different operating condition of using pressure - difference bypassing control in primary water pump system. using load control method in the change of the operating condition of primary water pump system can realize that the load change is small and reasonable in the on / off condition of pumps and m m chiller by comparing load control method in primary variable - flow water pump system with pressure - difference bypassing control method, back water temperature control method

    本論文從目前空調工程中使用的變流量水系統入手,研究了器在部分負荷下水流量與換量的非線性關系,分析了文獻中介紹的旁通通流能力選擇的不足之處和一次泵水系統採用壓差旁通控制時,工況轉換不能滿足系統控制要求的缺陷;比較了一次泵變流量水系統中壓差旁通控製法、回水溫度控製法、負荷控製法的精確性,並得出了在一次泵水系統的工況轉換時,採用負荷控製法能使冷水機組及其相應水泵在啟停時的負荷變化范圍較小,更符合建築物的冷量需求,節能效果較好的結論。
  16. Chilled water coil are controlled in much the same way as heating.

    冷水的控和加熱盤管的差不多相同。
  17. The piping system is designed for full flexibility, permitting all modes of operation, in and out with tank truck, rail tank car and vessel, as well as drumming

    所有儲罐均有產品蒸汽控制、氮氣補償、快速清洗裝置,並可迅速安裝加熱盤管和保溫裝置,以備所需。
  18. Steam heating coil

    蒸汽加熱盤管
  19. Methods of testing forced circulation air cooling and air heating coils

    強制循環空冷卻和空氣加熱盤管的試驗方法
  20. In place of the reboiler, a heating coil may be placed in the bottom of the column to generate vapor from the pool of liquid there

    例如可以在精餾塔的底部安裝一個加熱盤管代替再沸器,加釜液產生蒸汽。