熱膨脹調節 的英文怎麼說

中文拼音 [péngzhàngdiàojié]
熱膨脹調節 英文
accommodation of heat expansion
  • : 動詞(物體的長度或體積增加) expand; swell
  • : 動詞1. (膨脹) expand; dilate; inflate 2. (脹大) swell; distend; bloat
  • 調 : Ⅰ動詞1 (配合得均勻合適) harmonize; suit well; fit in perfectly 2 (使配合得均勻合適) mix; adju...
  • : 節構詞成分。
  • 膨脹 : expand; swell; dilate; inflate; puff; bulge; inflation; expansion; dilatation; buckling; swelling...
  • 調節 : regulate; adjust; monitor; measure; take care of; condition; regulation; adjustment; conditioning...
  1. The software takes visual basic6. 0 as work flat, adopting activex technique, transfers autocad2000 painting orders from the exterior of vb through programme method. it is a re - exploitation software to design bellows expansion joints. the software adopts ejma, the current international widespread trade standard, as mathematics model

    波紋是安裝在金屬管線上起補償、柔性連接等作用的管道連接構件,本文以visualbasic6 . 0作為操作平臺,採用activex技術,通過編程手段從vb外部調用autocad2000軟體中的繪圖命令,二次開發軟體,以目前國際上行業中普遍採用的ejma標準作為數學模型,編輯波紋設計軟體。
  2. They will short down the working life of air compressor because they are always started or stopped when we want to make the railway carriage stay in a fixed temperature. now, automatic and intelligent control systems are being applying in bus air - conditions control. in this way, computers control the work of air compressor, the turnaround speed of fan, the open degrees of wind controlled doors and so on

    我國大多數客車空調仍然採用簡單的壓縮機開關控制及循環離合控制系統,如:離合器?閥系統( cctxv )和離合器?流管系統( ccot ) ,這些控制方式的精度低,當進行恆溫控制時壓縮機處于頻繁的開、停狀態,縮短了壓縮機的工作壽命。
  3. The results show that, when the compressor continuously runs, the stability of the test bed after using manual valve is better than that of using thermal valve, and it is little affected by the kinds of valves for adjusting cooling water ; and that, when the compressor intermittently runs, the operation stability would be obtained if pneumatic valve is used to adjust cooling water, especially at low speed

    結果表明,壓縮機連續運行時,製冷劑採用手動閥調后工況的穩定性明顯好於採用閥時的情況,此時調冷卻水量用的電動調閥和氣動調閥對工況穩定性影響相差無幾;間歇運行時,無論是閥還是手動閥,即便壓縮機通電時間最長,仍達不到設定工況,特別是低速的斷續尤為明顯,而使用氣動閥就能很好地解決這一問題。
  4. The input of the heater is controlled with proportional - integral - differential ( pid ) logic. the flux of the cooling fluid is regulated by electronic expansion valve

    系統採用pid演算法控制導電鍍膜的加量,同時使用電子調冷卻介質的流量。
  5. When a reducing valve is used, it makes a closed system ; therefore, a pressure relief valve must be installed in the downstream side of the regulator to protect equipment against excess pressure which is built up by the expansion of water from the domestic hot water supply tank or heater

    如果採用減壓閥,將形成一個封閉系統;因此必須在調閥的下游位置安裝一個壓力安全閥,以保護設備不會由於室內水供應容器或水器造成的水而變得壓力過大。