短接線 的英文怎麼說

中文拼音 [duǎnjiēxiàn]
短接線 英文
shorting stub
  • : Ⅰ形容詞(空間、時間兩端之間的距離小) short; brief Ⅱ動詞(缺少; 欠) lack; owe Ⅲ名詞1 (缺點) we...
  • : Ⅰ動詞1 (靠近;接觸) come into contact with; come close to 2 (連接; 使連接) connect; join; put ...
  • : 名詞1 (用絲、棉、金屬等製成的細長的東西) thread; string; wire 2 [數學] (一個點任意移動所構成的...
  • 接線 : 1 [電學] (連接導線) wiring2 (電話員接通線路) work a telephone switchboard; connection接線插座...
  1. This form of construction is strong and has the additional advantage of enclosing a given volume with the least possible use of materials. geodesic domes are actually derived from regular polyhedra. those that are derived from the dodecahedron and the icosahedron have joints where 5 distinct triangles meet

    由正十二或正二十面所建而成的圓頂特色是當中的一些駁點由五個三角形組成而由正八面體所建立的圓頂則可以分割成四分之一或四分之三個。
  2. Two kinds of new on - line monitoring methods, which are based on measuring primary, secondary currents and voltages to calculate the short - circuit reactances of windings for detecting the deformation windings of power transformer, are proposed in the paper. the methods used for on - line measuring the short - circuit reactances of traction transformer in electric railways, are designed

    本文提出了兩種在監測變壓器繞組變形的方法,通過在監測變壓器繞組原、次邊的電壓和電流量,實時計算變壓器繞組的路電抗來判斷變壓器繞組變形情況,並對電氣化鐵路主要型式的牽引變壓器繞組變形的在監測方案進行了設計。
  3. The development of a visual short circuit software under ptcad2000 is presented in this paper, as well as the system structure, the definition of the data structure, the interface to ptcad2000, the conversion of the original wiring diagram of power network to calculable power network, the implement of three sequence network, the implement of impendence matrix and admittance matrix of power network considering the zero sequence mutual inductances among lines, and the implement of short circuit calculation by using computer

    本文介紹了在ptcad2000平臺下路電流可視化計算軟體的開發。介紹了軟體的系統結構、數據結構定義、與ptcad2000平臺的介面、電力系統原始圖轉成等值可計算網路、序網的生成、考慮零序互感路阻抗時電網導納矩陣和阻抗矩陣的生成,以及故障點路電流計算的計算機實現。
  4. A new type of joint technique between short _ net copper pipe and soft _ cable connection board, castfusion welding, is introduced. the practice of more than ten years shows that this fusion welding connection has the superiority of higher reliability, simpler processing method, better economy benefit compared to the taper cone face - contacted connection

    介紹了電石爐網銅管與軟纜板之間的一種新型連技術? ?澆鑄熔焊技術.經過10多年的運行,實踐證明網銅管與鑄銅軟纜板的澆鑄熔焊連,與傳統工藝採用的圓錐面觸連相比較,具有加工工藝簡單、運行可靠性高、經濟效益好等優點
  5. Line short circuit

  6. Externally mounted breakers are defined as self - contained devices which are mounted individually or in combination via brackets, bus bars, plugged into terminal blocks, or panel mounted

    外裝式路器,一獨立式裝置,可自行安裝,也可通過支撐,母插入盤或盤桂內進行裝配。
  7. This article develops a research on the underwater acoutics position technology with the short array - group and designs hardware of this system based on application background, which includes the receiver, controlling sub system and interface sub system and the wave ( data ) collecting sub system

    本論文對水聲定位技術進行了研究並設計了基於工程應用背景下的硬體電路系統。主要包括:收機分系統、控制及介面分機分系統和波形(數據)採集分系統。
  8. Shorts between metal runners are important only in those regions of the chip with a high density of closely packed metal runners.

    金屬布間的,僅在那些具有高密度密集封裝型金屬布的晶元中才極為重要。
  9. Indicates that the character is a punctuation that is not a connector punctuation, a dash punctuation, an open punctuation, a close punctuation, an initial quote punctuation, or a final quote punctuation

    指示字元是標點,但它不是連符標點、標點、開始標點、結束標點、前引號標點或后引號標點。
  10. A removable board containing hundreds of terminals into which patch cords ( short wires ) are connected ( these determine the different programs for the machine )

    一塊可移動的板,裝有幾百個端子,用短接線)將端子連起來,這些連決定了機器的不同程序。
  11. After electric heating system is installed, check electrical insulation of all circuits. the insulation resistance between generatrix and shielding layer, core wires of series cable before connection at end not be less than 20 m. and then check if dc resistance of circuit is normal and phase resistance is banlance

    電伴熱系統安裝完工後,應逐路檢查系統的絕緣電阻:各種電熱帶母與屏蔽層之間、串聯帶芯尾端末前的各芯間絕緣電阻均應不小於20m ;然後再檢查電熱帶直流電阻是否正常,三相電阻是否平衡。
  12. Firstly, the basic theory of the ultra - short baseline system is dissertated. and then, several typical localization model of four cell lineup is analyzed and investigated thoroughly. a optimal localization model is educed by contrasting performance and analyzing precision

    首先論述了現有超被動聲定位系統的基本理論,緊著深入研究了幾種典型的四元方陣的定位模型,通過性能對比、精度分析,討論得出了最優的定位模型。
  13. To improve the roundness of the polyhedron, we can divide the edges into shorter lengths and raise the points of division to a geodesic on the surface of a sphere

    由於正多面體不太圓,在每個面上增加連棒相當于可令圓度增加。
  14. On - line monitoring of hvcb is the precondition of predicting maintenance, is the key element of reliable run, and is the important supplement to the traditional off - line preventive maintenance in fact, the faults are made by hvcb, no matter in number or in times, is over 60 % of total faults so it has determinative importance for improving the reliability of power supply and this can greatly decrease the capital waste used by - dating overhaul in this paper, the inspecting way of hvcb mechanism characteristic is discussed the concept of sub - circuit protector is presented, the scheme that we offered has been combined with sub - circuit integrality monitoring theory, to ensure that it has the two functions as a whole according the shut - off times at rated short circuit given by hvcb manufacturer, the electricity longevity loss can be calculated in each operation, and the remained longevity can be forecast too an indirect way for calculating main touch ' s temperature by using breaker shell temperature, air circumference temperature and breaker ' s heat resistance is improved in this paper, and main touch resistance can be calculated if providing the load current msp430, a new single chip microcomputer made by ti company, is engaged to develop the hardware system of the on - line monitoring device, and special problem brought by the lower supply voltage range of this chip is considered fully

    高壓斷路器所造成的事故無論是在次數,還是在事故所造成的停電時間上都占據總量60以上。因此,及時了解斷路器的工作狀態對提高供電可靠性有決定性意義;並可以大大減少盲目定期檢修帶來的資金浪費。本文論述了斷路器機械特性參數監測方法;提出了二次迴路保護器的概念,並將跳、合閘圈完整性監視和二次迴路保護結合起來,給出具有完整性監視功能的二次迴路保護器實現方案;根據斷路器生產廠家提供的斷路器額定路電流分斷次數,計算每次分閘對應的觸頭電壽命損耗,預測觸頭電壽命;提出根據斷路器殼體溫度和斷路器周圍空氣溫度結合斷路器熱阻來計算斷路器主觸頭穩態溫升的方法,並根據此時的負荷電流間計算主觸頭迴路的電阻;在硬體電路設計上,採用美國ti公司最新推出的一種功能強大的單片機msp430 ,並充分考慮該晶元的適用電壓范圍給設計帶來的特殊問題;在通信模塊的設計中,解決了不同工作電壓晶元之間的介面問題,並給出了直方案。
  15. The advantages of the cascade configuration include the fact that there are no unterminated stubs and the configuration is easily expandable

    級聯配置的優點包括沒有未端,並且配置非常容易擴展。
  16. Some of these considderationsinclude insertion loss, cross talk, propagation delay, and unterminated stubs

    需要考慮的因素包括插入損耗、串擾、傳輸延遲和未端
  17. In this case components should be mounted on a board having a continuous copper ground plane ( ideally on both sides of the board, though while convenient this is not essential ), with ground connections made to the plane and short point to point wiring made above and below it

    用於搭試的電路板最好有連續的地層(如果雙面都有地層就更理想了,雖然調試起來會不太方便) ,這樣地的導和層間連都會比較
  18. Based on the activex technology, electric component menus and toolbars are created in this paper, with which a net wiring diagram for power electronics system is drawn. take advantage of autocad events, it is easy to fully carry out the consistency between graphics and data, from which users can manage databases and visual operation on graphics. the graphics about short - circuit current distribution and protection coupling are auto - drawn by using the autocad entity and text objects

    本文採用activex技術,創建電氣元件菜單和工具欄,方便用戶繪制電力系統網路圖;利用autocad事件,實現圖形數據的一體化,從而可以使用戶在圖形上操作和管理數據庫以及計算的可視化操作;利用autocad的圖形和文本對象來自動繪制路電流分布圖和保護整定圖。
  19. In electronics, a small length of cable with suitable end connectors for use in a patch panel

    在電子技術中,板上使用的兩端帶有配套插件的電纜。
  20. Fcd. 3 138g : 4ds outer - thread copper pipe union at both ends of the inlet and the outlet this valve uses the principle of two - stage pressure reducing variation and, when to lower the switch valve, the shock from the water pressure to the valve casing shortens the start time of this valve under the highest medium pressure and makes it with the incomparable superiority of energy saving among the pulse - type electric - controlled valves, combining to increase filtered to regulate the discharge function with machine type

    該閥採用二級減壓變化原理,降低開關閥時水壓對閥體等配件的沖擊,提高電磁閥的可靠性和工作壽命,縮了閥在最高介質壓力下開啟時間,使其在脈沖式電控閥門中具有無可倫比的節能優勢,並在上採用密封插件,並增加了過濾器和機械式調節流量功能。
分享友人